Measurement of subcutaneous adipose tissue thickness by near-infrared

被引:0
|
作者
Yu Wang
Zeqiang Yang
Dongmei Hao
Song Zhang
Yimin Yang
Yanjun Zeng
机构
[1] Beijing University of Technology,College of Life Science and Bioengineering
关键词
Subcutaneous adipose tissue (SAT); Near-Infrared; Skinfold caliper; Linear regression; Support vector regression (SVR);
D O I
暂无
中图分类号
学科分类号
摘要
Obesity is strongly associated with the risks of diabetes and cardiovascular disease, and there is a need to measure the subcutaneous adipose tissue (SAT) layer thickness and to understand the distribution of body fat. A device was designed to illuminate the body parts by near-infrared (NIR), measure the backscattered light, and predict the SAT layer thickness. The device was controlled by a single-chip microcontroller (SCM), and the thickness value was presented on a liquid crystal display (LCD). There were 30 subjects in this study, and the measurements were performed on 14 body parts for each subject. The paper investigated the impacts of pressure and skin colour on the measurement. Combining with principal component analysis (PCA) and support vector regression (SVR), the measurement accuracy of SAT layer thickness was 89.1 % with a mechanical caliper as reference. The measuring range was 5–11 mm. The study provides a non-invasive and low-cost technique to detect subcutaneous fat thickness, which is more accessible and affordable compared to other conventional techniques. The designed device can be used at home and in community.
引用
收藏
页码:201 / 208
页数:7
相关论文
共 50 条
  • [21] Near-infrared application for tissue identification
    Botonjic, Edita
    Fawcett, Steven
    SMART MEDICAL AND BIOMEDICAL SENSOR TECHNOLOGY IV, 2006, 6380
  • [22] NEAR-INFRARED RADIATION FOR DIAGNOSIS OF TISSUE
    RESCHKE, J
    TAUBERT, J
    MENDE, M
    BIOMEDIZINISCHE TECHNIK, 1993, 38 (7-8): : 162 - 167
  • [23] Quantification in tissue near-infrared spectroscopy
    Delpy, DT
    Cope, M
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) : 649 - 659
  • [24] AN OPTICAL SYSTEM TO MEASURE THE THICKNESS OF THE SUBCUTANEOUS ADIPOSE TISSUE LAYER
    Hong, Hyuck Ki
    Jo, Young Chang
    Choi, Yeon Shik
    Park, Hyo Derk
    Kim, Beom Joon
    2009 IEEE SENSORS, VOLS 1-3, 2009, : XX - XXIII
  • [25] ULTRASONIC MEASUREMENTS OF SUBCUTANEOUS ADIPOSE-TISSUE THICKNESS IN MAN
    JONES, PRM
    DAVIES, PSW
    NORGAN, NG
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1986, 71 (03) : 359 - 363
  • [26] Comparison between tissue oxygen saturation as determined by near-infrared spectroscopy and direct measurements of subcutaneous tissue oxygen
    Akca, O
    Doufas, AG
    Lin, CM
    Sessler, DI
    ANESTHESIOLOGY, 2002, 97 (03) : B15 - B15
  • [27] Measurement of Tissue Oxygenation using Near-infrared Spectroscopy in Patients undergoing Hemodialysis
    Ito, Kiyonori
    Ookawara, Susumu
    Uchida, Takayuki
    Hayasaka, Hideyuki
    Kofuji, Masaya
    Miyazawa, Haruhisa
    Aomatsu, Akinori
    Ueda, Yuichiro
    Hirai, Keiji
    Morishita, Yoshiyuki
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (164):
  • [28] Rapid and nondestructive measurement of glucose in a skin tissue phantom by near-infrared spectroscopy
    Xue Jintao
    Ye Liming
    Li Chunyan
    Zhang Mingxiang
    Li Peng
    OPTIK, 2018, 170 : 30 - 36
  • [29] Development of a tissue oxygen consumption measurement method based on near-infrared photoplethysmography
    Nogawa, M
    Tanaka, S
    Shibata, M
    Yamakoshi, K
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2227 - 2230
  • [30] In vivo lactate measurement in human tissue by near-infrared diffuse reflectance spectroscopy
    Lafrance, D
    Lands, LC
    Burns, DH
    VIBRATIONAL SPECTROSCOPY, 2004, 36 (02) : 195 - 202