Accuracy of the catalyst surface guidance system for patient monitoring during cranial SRS treatments

被引:0
|
作者
Katherine Tonkin
Simon K. Goodall
机构
[1] GenesisCare,School of Physics, Mathematics and Computing
[2] University of Western Australia,undefined
关键词
Surface guidance radiotherapy; Stereotactic radiosurgery; Intrafraction monitoring; Optical surface imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The use of surface guided imaging in cranial stereotactic radiotherapy provides a non-ionising form of patient position verification that gives information on when patient position errors may require corrections to be applied. This work assessed the accuracy of Catalyst+ HD system for treatment geometries commonly used in cranial SRS. Average Catalyst reported error as a function of couch rotation agreed with measured kV and MV walkout within 0.5 mm for the lateral and longitudinal directions. Change in Catalyst reported error with isocentre depth relative to the monitoring region of interest (ROI) from the surface was assessed and showed variation above 0.5 mm, but within 1 mm for isocentre depths ranging from 3 to 15 cm from the phantom surface. Gantry occlusion of Catalyst cameras caused a shift in reported position error that was also dependent on isocentre depth relative to the monitoring ROI. SRS MapCHECK patients specific QA results showed improvement in gamma passing rates for a workflow where Catalyst reported errors above 0.5 mm were corrected.
引用
收藏
页码:633 / 643
页数:10
相关论文
共 50 条
  • [31] Design Adaptive Controller and Guidance System of an Unmanned Surface Vehicle for Environmental Monitoring Applications
    Ngoc-Huy Tran
    Nguyen-Nhut-Thanh Pham
    [J]. PROCEEDINGS OF 2018 4TH INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2018, : 615 - 620
  • [32] Continuous Patient Surface Monitoring and Motion Analysis During Lung SBRT
    Chung, E.
    Rioux, A.
    Benedict, S.
    Yamamoto, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3310 - 3310
  • [33] A Wireless Patient Monitoring System for Hospitalized Older Adults: Acceptability, Reliability and Accuracy Evaluation
    Baig, Mirza Mansoor
    GholamHosseini, Hamid
    Connolly, Martin J.
    Kashfi, Ghodsi
    [J]. 2014 IEEE-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI), 2014, : 330 - 333
  • [34] ACTIVE SURFACE MONITORING FOR REAL-TIME CLINICAL GUIDANCE DURING PELVIC ADAPTIVE RADIOTHERAPY
    Keiper, Timothy
    Kim, Grace Gwe-Ya
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S34 - S34
  • [35] Accuracy of continuous glucose monitoring system during exercise in type 2 diabetes
    Figueira, Franciele R.
    Umpierre, Daniel
    Ribeiro, Jorge P.
    Tetelbom, Pedro S.
    Henn, Nicoli T.
    Esteves, Jorge F.
    Schaan, Beatriz D.
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2012, 98 (03) : E36 - E39
  • [36] Performance of the GLUCOCARD® Shine XL Blood Glucose Monitoring System Compared with FDA 2016 Guidance Accuracy Criteria
    Walker, Julie
    Gill, Patricia
    Maher, Danielle
    Gleisner, John M.
    [J]. DIABETES, 2018, 67
  • [37] Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study
    Mancosu, Pietro
    Fogliata, Antonella
    Stravato, Antonella
    Tomatis, Stefano
    Cozzi, Luca
    Scorsetti, Marta
    [J]. MEDICAL DOSIMETRY, 2016, 41 (02) : 173 - 179
  • [38] High accuracy monitoring system to estimate forest road surface degradation on horizontal curves
    Yurtseven, Huseyin
    Akgul, Mustafa
    Akay, Anil Orhan
    Akburak, Serdar
    Cigizoglu, Hikmet Kerem
    Demir, Murat
    Ozturk, Tolga
    Eksi, Mert
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2019, 191 (01)
  • [39] High accuracy monitoring system to estimate forest road surface degradation on horizontal curves
    Huseyin Yurtseven
    Mustafa Akgul
    Anil Orhan Akay
    Serdar Akburak
    Hikmet Kerem Cigizoglu
    Murat Demir
    Tolga Ozturk
    Mert Eksi
    [J]. Environmental Monitoring and Assessment, 2019, 191
  • [40] Bed surface monitoring system for catalyst dense loading process in fixed bed reactor
    Liu M.
    Liu X.
    Xu X.
    Peng T.
    Gu Y.
    Jiang W.
    [J]. Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (07): : 3617 - 3625