Accuracy of the catalyst surface guidance system for patient monitoring during cranial SRS treatments

被引:0
|
作者
Katherine Tonkin
Simon K. Goodall
机构
[1] GenesisCare,School of Physics, Mathematics and Computing
[2] University of Western Australia,undefined
关键词
Surface guidance radiotherapy; Stereotactic radiosurgery; Intrafraction monitoring; Optical surface imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The use of surface guided imaging in cranial stereotactic radiotherapy provides a non-ionising form of patient position verification that gives information on when patient position errors may require corrections to be applied. This work assessed the accuracy of Catalyst+ HD system for treatment geometries commonly used in cranial SRS. Average Catalyst reported error as a function of couch rotation agreed with measured kV and MV walkout within 0.5 mm for the lateral and longitudinal directions. Change in Catalyst reported error with isocentre depth relative to the monitoring region of interest (ROI) from the surface was assessed and showed variation above 0.5 mm, but within 1 mm for isocentre depths ranging from 3 to 15 cm from the phantom surface. Gantry occlusion of Catalyst cameras caused a shift in reported position error that was also dependent on isocentre depth relative to the monitoring ROI. SRS MapCHECK patients specific QA results showed improvement in gamma passing rates for a workflow where Catalyst reported errors above 0.5 mm were corrected.
引用
收藏
页码:633 / 643
页数:10
相关论文
共 50 条
  • [1] Accuracy of the catalyst surface guidance system for patient monitoring during cranial SRS treatments
    Tonkin, Katherine
    Goodall, Simon K.
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) : 633 - 643
  • [2] Setup and Monitoring in SRS Treatments with Surface Imaging
    Cervino, L.
    Detorie, N.
    Taylor, M.
    Lawson, J.
    Harry, T.
    Murphy, K.
    Mundt, A.
    Jiang, S.
    Pawlicki, T.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3620 - +
  • [3] Intrafractional patient movement during an online adaptive replanning procedure for cranial SRS
    Pozo-Masso, M.
    Calvo-Ortega, J. F.
    Moragues-Femenia, S.
    Casals-Farran, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S848 - S849
  • [4] Clinical Experience with Monitoring Frequency of Intra-Fraction Patient Motion Using the ExacTrac System for SRS Treatments
    Lewis, B.
    Snyder, W.
    Hugo, G.
    Kim, S.
    Kim, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3313 - 3313
  • [5] Monitoring frequency of intra-fraction patient motion using the ExacTrac system for LINAC-based SRS treatments
    Lewis, Benjamin C.
    Snyder, William J.
    Kim, Siyong
    Kim, Taeho
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 58 - 63
  • [6] Optical surface guidance for submillimeter monitoring of patient position during frameless stereotactic radiotherapy
    Covington, Elizabeth L.
    Fiveash, John B.
    Wu, Xingen
    Brezovich, Ivan
    Willey, Christopher D.
    Riley, Kristen
    Popple, Richard A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 91 - 98
  • [7] Analysis of a Non-Invasive Patient Mask Immobilization System for Cranial SRS with TomoTherapy
    Bichay, T.
    Kane, J.
    Ebrom, P.
    Chen, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Validation of optical surface/thermal imaging and X-ray positioning accuracy for SRS treatments
    Mendes, V. da Silva
    Reiner, M.
    Corradini, S.
    Niyazi, M.
    Belka, C.
    Landry, G.
    Freislederer, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S612 - S613
  • [9] Accuracy evaluation of the Optical Surface Monitoring System on EDGE linear accelerator for patient positioning
    Palumbo, V.
    Mancosu, P.
    Stravato, A.
    Ascolese, A. M.
    Fogliata, A.
    Cozzi, L.
    Gaudino, A.
    Lobefalo, F.
    Navarria, P.
    Reggiori, G.
    Scorsetti, M.
    Tomatis, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S915 - S916
  • [10] Intrinsic Uncertainty in the Positional Accuracy Determined by Stereotactic Image Guidance System in Cranial Robotic Radiosurgery
    Thiyagarajan, Rajesh
    Karrthick, K. P.
    Nambiraj, Arunai
    Selvan, Tamil
    Abhishek, Ashu
    Rajendran, Sasi
    Raju, Merin
    Kataria, T.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3208 - 3208