Multislice CT-image-guided endoscopic sinus surgery using an electromagnetic tracking system

被引:0
|
作者
P. Reittner
M. Tillich
W. Luxenberger
R. Weinke
K. Preidler
W. Köle
H. Stammberger
D. Szolar
机构
[1] Department of Radiology,
[2] Karl Franzens Medical School and University Hospital Graz,undefined
[3] Auenbruggerplatz 9,undefined
[4] 8036 Graz,undefined
[5] Austria,undefined
[6] Department of ENT,undefined
[7] Karl Franzens Medical School and University Hospital Graz,undefined
[8] Auenbruggerplatz 9,undefined
[9] 8036 Graz,undefined
[10] Austria,undefined
[11] Diagnostikum Graz-Südwest,undefined
[12] Weblinger Gürtel 25,undefined
[13] 8045 Graz,undefined
[14] Austria,undefined
来源
European Radiology | 2002年 / 12卷
关键词
Computer-assisted surgery Head and neck Electromagnetic tracking system Sinus surgery Multislice CT;
D O I
暂无
中图分类号
学科分类号
摘要
Our objective was to assess the practicability and accuracy of a computer-assisted multislice CT-guided frameless electromagnetic tracking for endoscopic sinus surgery. Eighty-two patients with various paranasal sinus diseases were evaluated. Prior to surgery, axial multislice spiral-CT scans with 2.5-mm collimation, 0.8-mm reconstruction increment, and a pitch of 3 were acquired. After Ethernet transfer of the CT data set to the guidance system, coronal and sagittal images were reconstructed. For intraoperative navigation the Insta Trak System (Visualization Technology, Boston, Mass.) was used. Navigational procedures are described in detail in the paper. Accuracy was assessed by means of visual landmarks which could be clearly identified endoscopically as well as on CT images. A second parameter for accuracy was calculated by the system itself as the root mean square (RMS). The system was able to display the position of the aspirating tip relative to anatomical structures with an average accuracy of 0.70±0.40 mm. Root mean square values showed a mean value of 0.40±0.20 mm. During surgical procedures the Insta Trak System provides the surgeon with additional image-based information to the endoscopic view. The device accuracy is high and the system proves to be practicable and efficient in ENT surgery.
引用
收藏
页码:592 / 596
页数:4
相关论文
共 50 条
  • [1] Multislice CT-image-guided endoscopic sinus surgery using an electromagnetic tracking system
    Reittner, P
    Tillich, M
    Luxenberger, W
    Weinke, R
    Preidler, K
    Köle, W
    Stammberger, H
    Szolar, D
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (03) : 592 - 596
  • [2] Application of image-guided system to endoscopic sinus surgery
    Murata, H
    Tomoda, K
    [J]. CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 651 - 655
  • [3] Image-guided endoscopic surgery: Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system
    Fried, MP
    Kleefield, J
    Gopal, H
    Reardon, E
    Ho, BT
    Kuhn, FA
    [J]. LARYNGOSCOPE, 1997, 107 (05): : 594 - 601
  • [4] Image-Guided Endoscopic Surgery: Results of Accuracy and Performance in a Multicenter Clinical Study Using an Electromagnetic Tracking System
    Fried, Marvin P.
    Kleefied, Jonathan
    Gopal, Harsha
    Reardon, Edward
    Ho, Bryan T.
    Kuhn, Frederick A.
    [J]. LARYNGOSCOPE, 2015, 125 (04): : 774 - 781
  • [5] Image-guided functional endoscopic sinus surgery
    Olson, G
    Citardi, MJ
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2000, 123 (03) : 188 - 194
  • [6] An image-guided sinus surgery system
    Spinko, Vladimir
    Shi, Da-Ming
    Ng, Wan Sing
    Hayfron-Acquah, James B.
    [J]. PROCEEDINGS OF 2007 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2007, : 166 - +
  • [7] Image-guided navigation surgery for pelvic malignancies using electromagnetic tracking
    Nijkamp, Jasper
    Kuhlmann, Koert
    Sonke, Jan-Jakob
    Ruers, Theo
    [J]. MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [8] Endoscopic tracking for use in interactive, Image-Guided Surgery
    Stefansic, JD
    Herline, AJ
    Chapman, WC
    Galloway, RL
    [J]. IMAGE DISPLAY - MEDICAL IMAGING 1998, 1998, 3335 : 208 - 218
  • [9] Advantages of using an image-guided system for transnasal endoscopic surgery
    Han, DM
    Zhou, B
    Ge, WT
    Zhang, L
    Zhang, YJ
    [J]. CHINESE MEDICAL JOURNAL, 2003, 116 (07) : 1106 - 1107
  • [10] Advantages of using an image-guided system for transnasal endoscopic surgery
    韩德民
    周兵
    葛文彤
    张罗
    张永杰
    [J]. Chinese Medical Journal, 2003, (07)