A fast and direct determination of bisphenol S in thermal paper samples using paper spray ionization mass spectrometry

被引:0
|
作者
Ricardo Alves Bernardo
Jean Carlos Pereira Sousa
Matheus Gallimberti
Fernando Barbosa Junior
Boniek Gontijo Vaz
Andréa Rodrigues Chaves
机构
[1] Federal University of Goiás,Institute of Chemistry
[2] University of São Paulo,Faculty of Pharmaceutical Sciences of Ribeirão Preto
关键词
Bisphenol S; Thermal paper; Paper spray ionization; Ambient ionization; Mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Concerns about human health regarding the large use of bisphenol A in thermal papers have led to its replacement by bisphenol S. Analyses of bisphenols require several sample pretreatment steps, which are laborious, expensive, and time-consuming. A paper spray ionization mass spectrometry (PSI-MS) was developed to detect and quantify bisphenol S in three different brands of thermal papers commercially available. Parameters such as paper size, and paper position relative to the mass spectrometer inlet were evaluated. The analyses were performed in selected ion monitoring mode on a linear ion trap mass spectrometer. The developed method presented absolute recovery values ranging from 92.2 to 109.04%, accuracy values from −1.2 to 9.0%, and inter assay precision from 1.8 to 5.6% and enabled LOD as low as 5 ng g−1. The concentration of bisphenol S in all of the three brands of BPA-free thermal papers evaluated ranged from 1.36 to 6.77 μg g−1, and the concentrarion of BPA ranged from 6.56 to 16.4 μg g−1 in all samples of thermal paper evaluated. The PSI-MS method described here was comparable to the conventional ones, such as liquid chromatography coupled with mass spectrometry and gas chromatography coupled with mass spectrometry described in the literature. The present study proved to be practical, fast, and efficient for the direct determination of bisphenol S in thermal papers. Furthermore, the methodology here described showed to be a promising alternative to replace the classical methods for determination of bisphenol S, due to its simplicity, and no needing of any sample pretreatment.
引用
下载
收藏
页码:57288 / 57296
页数:8
相关论文
共 50 条
  • [31] In Situ Separation and Analysis of Lipids by Paper Spray Ionization Mass Spectrometry
    Kal, Youngju
    Cha, Sangwon
    MOLECULES, 2021, 26 (01):
  • [32] Identification and Confirmation of Fentanyls on Paper using Portable Surface Enhanced Raman Spectroscopy and Paper Spray Ionization Mass Spectrometry
    Fedick, Patrick W.
    Pu, Fan
    Morato, Nicolas M.
    Cooks, R. Graham
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (03) : 735 - 741
  • [33] DETERMINATION OF DESIGNER DRUGS IN SALIVA BY PAPER SPRAY MASS SPECTROMETRY
    Maciel, Lanaia Itala L.
    Carvalho, Thays C.
    Pereira, Igor
    Vaz, Boniek G.
    QUIMICA NOVA, 2019, 42 (06): : 676 - 682
  • [34] Direct and rapid quantitation of ephedrines in human urine by paper spray ionization/high resolution mass spectrometry
    Jeong, Eun Sook
    Kim, Ki Hun
    Cha, Eunju
    Kwon, Oh-Seung
    Cha, Sangwon
    Lee, Jaeick
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1028 : 237 - 241
  • [35] Paper spray mass spectrometry applied to the detection of cocaine in simulated samples
    Almeida de Paula, Camila Cristina
    Lordeiro, Rogerio Araujo
    Piccin, Evandro
    Augusti, Rodinei
    ANALYTICAL METHODS, 2015, 7 (21) : 9145 - 9149
  • [36] Authenticity study of commercial samples of St. John's wort by paper spray ionization mass spectrometry and chemometric tools
    Miguita, Ana Gabriella Carvalho
    Augusti, Rodinei
    Sena, Marcelo Martins
    Nascentes, Clesia Cristina
    JOURNAL OF MASS SPECTROMETRY, 2023, 58 (07):
  • [37] Direct Analysis and Quantification of Metaldehyde in Water using Reactive Paper Spray Mass Spectrometry
    Maher, Simon
    Jjunju, Fred P. M.
    Damon, Deidre E.
    Gorton, Hannah
    Maher, Yosef S.
    Syed, Safaraz U.
    Heeren, Ron M. A.
    Young, Iain S.
    Taylor, Stephen
    Badu-Tawiah, Abraham K.
    SCIENTIFIC REPORTS, 2016, 6
  • [38] Direct analysis of 4-methylimidazole in foods using paper spray mass spectrometry
    Li, Anyin
    Wei, Pu
    Hsu, Hsu-Chen
    Cooks, R. Graham
    ANALYST, 2013, 138 (16) : 4624 - 4630
  • [39] Direct Analysis and Quantification of Metaldehyde in Water using Reactive Paper Spray Mass Spectrometry
    Simon Maher
    Fred P. M. Jjunju
    Deidre E. Damon
    Hannah Gorton
    Yosef S. Maher
    Safaraz U. Syed
    Ron M. A. Heeren
    Iain S. Young
    Stephen Taylor
    Abraham K. Badu-Tawiah
    Scientific Reports, 6
  • [40] Determination of bisphenol A in thermal receipt paper water samples and lake water samples using fluorescence spectrophotometry
    Chitwood, Bailey
    Hubbard, Sara
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249