A fast and direct determination of bisphenol S in thermal paper samples using paper spray ionization mass spectrometry

被引:0
|
作者
Ricardo Alves Bernardo
Jean Carlos Pereira Sousa
Matheus Gallimberti
Fernando Barbosa Junior
Boniek Gontijo Vaz
Andréa Rodrigues Chaves
机构
[1] Federal University of Goiás,Institute of Chemistry
[2] University of São Paulo,Faculty of Pharmaceutical Sciences of Ribeirão Preto
关键词
Bisphenol S; Thermal paper; Paper spray ionization; Ambient ionization; Mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Concerns about human health regarding the large use of bisphenol A in thermal papers have led to its replacement by bisphenol S. Analyses of bisphenols require several sample pretreatment steps, which are laborious, expensive, and time-consuming. A paper spray ionization mass spectrometry (PSI-MS) was developed to detect and quantify bisphenol S in three different brands of thermal papers commercially available. Parameters such as paper size, and paper position relative to the mass spectrometer inlet were evaluated. The analyses were performed in selected ion monitoring mode on a linear ion trap mass spectrometer. The developed method presented absolute recovery values ranging from 92.2 to 109.04%, accuracy values from −1.2 to 9.0%, and inter assay precision from 1.8 to 5.6% and enabled LOD as low as 5 ng g−1. The concentration of bisphenol S in all of the three brands of BPA-free thermal papers evaluated ranged from 1.36 to 6.77 μg g−1, and the concentrarion of BPA ranged from 6.56 to 16.4 μg g−1 in all samples of thermal paper evaluated. The PSI-MS method described here was comparable to the conventional ones, such as liquid chromatography coupled with mass spectrometry and gas chromatography coupled with mass spectrometry described in the literature. The present study proved to be practical, fast, and efficient for the direct determination of bisphenol S in thermal papers. Furthermore, the methodology here described showed to be a promising alternative to replace the classical methods for determination of bisphenol S, due to its simplicity, and no needing of any sample pretreatment.
引用
下载
收藏
页码:57288 / 57296
页数:8
相关论文
共 50 条
  • [1] A fast and direct determination of bisphenol S in thermal paper samples using paper spray ionization mass spectrometry
    Bernardo, Ricardo Alves
    Sousa, Jean Carlos Pereira
    Gallimberti, Matheus
    Barbosa Junior, Fernando
    Vaz, Boniek Gontijo
    Chaves, Andrea Rodrigues
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (40) : 57288 - 57296
  • [2] Bisphenol determination in UHT milk and packaging by paper spray ionization mass spectrometry
    Soares, Daniel de Almeida
    Pereira, Igor
    Sousa, Jean Carlos Pereira
    Bernardo, Ricardo Alves
    Simas, Rosineide Costa
    Vaz, Boniek Gontijo
    Chaves, Andrea Rodrigues
    FOOD CHEMISTRY, 2023, 400
  • [3] Zero volt paper spray ionization mass spectrometry for direct analysis of samples on filter paper substrate
    Motoyama, Akira
    Kihara, Keishi
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (20) : 1905 - 1916
  • [4] Graphene Oxides Coated Paper as a Substrate to Paper Spray Ionization Mass Spectrometry for Creatinine Determination in Urine Samples
    Fernandes, Aline R.
    Bernardo, Ricardo A.
    de Carvalho, Thays C.
    Vaz, Boniek G.
    Chaves, Andrea R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2019, 30 (05) : 1074 - 1081
  • [5] Direct analysis of herbicides by paper spray ionization mass spectrometry
    Reeber, Steven L.
    Gadi, Sneha
    Huang, Sung-Ben
    Glish, Gary L.
    ANALYTICAL METHODS, 2015, 7 (23) : 9808 - 9816
  • [6] Rapid determination of lutein in fresh and commercial food samples using paper spray ionization mass spectrometry
    Alsaggaf, Wejdan T.
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2022, 155
  • [7] Paper spray ionization devices for direct, biomedical analysis using mass spectrometry
    Yang, Qian
    Wang, He
    Maas, Jeffrey D.
    Chappell, William J.
    Manicke, Nicholas E.
    Cooks, R. Graham
    Ouyang, Zheng
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2012, 312 : 201 - 207
  • [8] Ionization Suppression and Recovery in Direct Biofluid Analysis Using Paper Spray Mass Spectrometry
    Vega, Carolina
    Spence, Corina
    Zhang, Chengsen
    Bills, Brandon J.
    Manicke, Nicholas E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (04) : 726 - 734
  • [9] Biogenic aldehyde determination by reactive paper spray ionization mass spectrometry
    Bag, Soumabha
    Hendricks, P. I.
    Reynolds, J. C.
    Cooks, R. G.
    ANALYTICA CHIMICA ACTA, 2015, 860 : 37 - 42
  • [10] Direct analysis in real time accurate mass spectrometry determination of bisphenol A in thermal printing paper
    Castro, G.
    Rodriguez, I
    Ramil, M.
    Cela, R.
    TALANTA, 2019, 205