A hyperboloid mass spectrometer with an analyzer utilizing a three-dimensional ion trap bounded by the planez=0 is described. Potential distribution in a monopolar trap is numerically simulated and the influence of distortion function ΔU(z, r) on the trajectories of charged particles is investigated. Mass peaks for various operating modes of the analyzer are calculated. An experimental mass spectrometer with a monopolar ion trap has been investigated. Spectra of the residual atmosphere and of that with tetrachloromethane CCI4 puffed into the vacuum chamber have been measured. The resolution obtained isR0.5=1.2×103.
引用
收藏
页码:635 / 639
页数:4
相关论文
共 50 条
  • [31] A simulation study of the digital ion trap mass spectrometer
    Ding, L
    Sudakov, M
    Kumashiro, S
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 221 (02) : 117 - 138
  • [32] Dipole Excitation with a Paul Ion Trap Mass Spectrometer
    MacAskill, J. A.
    Madzunkov, S. M.
    Chutjian, A.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY: TWENTY-FIRST INTERNATIONAL CONFERENCE, 2011, 1336 : 127 - 131
  • [33] CHEMICAL IONIZATION IN AN ION TRAP MASS SPECTROMETER.
    Brodbelt, Jennifer S.
    Louris, John N.
    Cooks, R.Graham
    Analytical Chemistry, 1987, 59 (09): : 1278 - 1285
  • [34] HPLC-MS with an ion trap mass spectrometer
    Siethoff, C
    Wagner-Redeker, W
    Schäfer, M
    Linscheid, M
    CHIMIA, 1999, 53 (10) : 484 - 491
  • [35] NEW REGIME OF THE OPERATION OF HYPERBOLOID 3-DIMENSIONAL TRAP-TYPE MASS-SPECTROMETER
    SHERETOV, EP
    SAFONOV, MP
    KOLOTILIN, BI
    OVCHINNIKOV, SP
    GUROV, VS
    VESELKIN, NV
    BORISOVSKII, AP
    BANIN, VI
    PISMA V ZHURNAL TEKHNICHESKOI FIZIKI, 1989, 15 (09): : 85 - 87
  • [36] Ion soft landing using a rectilinear ion trap mass spectrometer
    Peng, Wen-Ping
    Goodwin, Michael P.
    Nie, Zongxiu
    Volny, Michael
    Zheng Ouyang
    Cooks, R. Graham
    ANALYTICAL CHEMISTRY, 2008, 80 (17) : 6640 - 6649
  • [37] Rapid Mass Analysis of Reserpine and Arginine by Ion Trap Mass Spectrometer
    Xu Fu-Xing
    Dang Qian-Kun
    Chen Yin-Juan
    Yang Kai
    Wang Qiang
    Chen Bin
    Wang Yuan-Yuan
    Ding Chuan-Fan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (06) : 949 - 953
  • [38] Study on Mass Calibration Segmentation Algorithm of Ion Trap Mass Spectrometer
    Pei H.-M.
    Liu M.-Y.
    Xu H.-Y.
    Zhang D.
    Xie J.
    Qu Z.-Y.
    Huang Z.-J.
    Jiang C.-Y.
    Meng Y.-Y.
    Dai X.-H.
    Fang X.
    Wang Q.-H.
    Jiang Y.
    Journal of Chinese Mass Spectrometry Society, 2023, 44 (05) : 676 - 684
  • [39] Investigation of the mass shifts caused by the coupling of ion motions in the ion trap mass spectrometer
    Mo, WJ
    Todd, JFJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (04) : 424 - 428
  • [40] Method for performing in-trap photoionization in a miniature ion trap mass spectrometer
    Stedwell, Corey
    DeBord, J.
    Spencer, Michael
    Rafferty, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252