The reliability of quantitative analysis on digital images of the scoliotic spine

被引:0
|
作者
John Cheung
Dirk J. Wever
Albert G. Veldhuizen
Jean P. Klein
Bert Verdonck
Rutger Nijlunsing
Jan C. Cool
Jim R. Van Horn
机构
[1] Department of Orthopaedic Surgery,
[2] University Hospital Groningen,undefined
[3] P.O. Box 30.001,undefined
[4] 9700 RB Groningen,undefined
[5] The Netherlands,undefined
[6] Department of Radiology,undefined
[7] University Hospital Groningen,undefined
[8] The Netherlands,undefined
[9] Philips Medical Systems Nederland B.V.,undefined
[10] Best,undefined
[11] The Netherlands,undefined
[12] Institute for Biomedical Technology,undefined
[13] University of Twente,undefined
[14] The Netherlands,undefined
来源
European Spine Journal | 2002年 / 11卷
关键词
Spine Scoliosis Radiographs Computer digital images Intraobserver repeatability;
D O I
暂无
中图分类号
学科分类号
摘要
Although analysis of scoliotic deformity is still studied extensively by means of conventional roentgenograms, computer-assisted digital analysis may allow a faster, more accurate and more complete evaluation of the scoliotic spine. In this study, a new computer-assisted measurement method was evaluated. This method uses digital reconstruction images for quantitative analysis of the scoliotic spine. The aim of the current study was to determine the reliability of the computer-assisted measuring method, which was done by establishing coefficients of repeatability for a variety of measurements. Measurements were carried out by five observers on 30 frontal and 10 lateral scoliotic digital reconstruction images. Each image was measured on three separate occasions by placing anatomical vertebral landmarks and drawing lines with a computer pointing device. The computer then calculated a number of geometrical shape parameters from scale calibration, landmarks and lines. The intra- and interobserver results were subjected to an analysis of variance to assess the level of agreement, and the means and standard deviations were calculated. The coefficient of repeatability (CR) was taken to be equal to two standard deviations. The mean intraobserver CR was found to be 3.1° for the Cobb angle on the frontal digital image and 3.3° for the kyphosis Cobb angle on the lateral overview. The mean difference in the intraobserver CR of the Cobb angle between measurements made by placing landmarks and those made by drawing lines was not statistically significant (P>0.05). The mean intraobserver CR for the other parameters can be summarized as follows: for lateral deviation it was 0.8 mm, for axial rotation 4.0° and for length of the spine 3.3 mm. The interobserver bias was negligible. It can be concluded that the reliability of our new method for quantifying geometrical variables on digital reconstruction images is better than measurements on conventional roentgenograms in previously published reports. The presented method is therefore considered to be more accurate for research of spinal deformities and more adequate for clinical management of scoliosis.
引用
收藏
页码:535 / 542
页数:7
相关论文
共 50 条
  • [41] Detorsion of a helix as a model for correction of the scoliotic spine
    Sawatzky, BJ
    Hughes, BL
    Tredwell, SJ
    RESEARCH INTO SPINAL DEFORMITIES 2, 1999, 59 : 134 - 136
  • [42] Computational modelling of the scoliotic spine: A literature review
    Gould, Samuele L.
    Cristofolini, Luca
    Davico, Giorgio
    Viceconti, Marco
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (10)
  • [43] Laser triangulation measurements of scoliotic spine curvatures
    Celan, Dusan
    Papez, Breda Jesensek
    Poredos, Primoz
    Mozina, Janez
    SCOLIOSIS AND SPINAL DISORDERS, 2015, 10
  • [44] Quantitative analysis of effects of the grid specifications on the quality of digital radiography images
    Lee, Sanghyun
    Chung, Woohyun
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) : 553 - 561
  • [45] QUANTITATIVE-ANALYSIS OF A STREAKLINE OBTAINED BY DIGITAL PROCESSING OF THE VISUALIZATION IMAGES
    BORLETEAU, JP
    COGNET, G
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II, 1986, 302 (04): : 151 - 156
  • [46] Quantitative analysis of effects of the grid specifications on the quality of digital radiography images
    Sanghyun Lee
    Woohyun Chung
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 553 - 561
  • [47] Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images
    Nakano, Asuka
    Mishima, Katsuaki
    Shiraishi, Ruriko
    Ueyama, Yoshiya
    COMPUTER AIDED SURGERY, 2015, 20 (01) : 29 - 33
  • [48] Three-dimensional reconstruction of the scoliotic spine and pelvis from uncalibrated biplanar x-ray images
    Kadoury, Samuel
    Cheriet, Farida
    Dansereau, Jean
    Labelle, Hubert
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (02): : 160 - 167
  • [49] A computerized method for evaluating scoliotic deformities using elliptical pattern recognition in X-ray spine images
    Pinheiro, Alan Petronio
    Coelho, Julio Cezar
    Paschoarelli Veiga, Antonio C.
    Vrtovec, Tomaz
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 161 : 85 - 92
  • [50] RELATIONS OF THE SOFT STRUCTURES OF THE POSTERIOR MEDIASTINUM IN THE SCOLIOTIC SPINE
    NATHAN, H
    ACTA ANATOMICA, 1988, 133 (03): : 260 - 264