Thickness-shear vibration of circular crystal plate in cylindrical shell as pressure sensor

被引:0
|
作者
Yuan-tai Hu
Zhi-jian Cui
Shu-nong Jiang
Jia-shi Yang
机构
[1] Central South University,Institute of Mechanics and Sensing Technology
[2] Huazhong University of Science and Technology,Department of Mechanics
[3] Xi’an Shiyou University,School of Petrolum Engineering
[4] University of Nebraska,Department of Engineering Mechanics
来源
Applied Mathematics and Mechanics | 2006年 / 27卷
关键词
pressure sensor; resonator; biasing fields; incremental fields; frequency shift; O343.5; 74B20;
D O I
暂无
中图分类号
学科分类号
摘要
Based on the theory for small fields superposed on relatively larger fields in an electroelastic body, a theoretical analysis is performed on a circular plate thickness-shear crystal resonator sealed in a circular cylindrical shell for pressure measurement. A simple expression is obtained for pressure induced frequency shifts in the resonator, which is examined for design optimization. Numerical results show that the frequency shifts depend linearly on the pressure, and that a pressure sensor with a softer outer shell or a smaller thickness ratio of the crystal plate to the outer shell has higher sensitivity.
引用
收藏
页码:749 / 755
页数:6
相关论文
共 50 条
  • [1] Thickness-shear vibration of circular crystal plate in cylindrical shell as pressure sensor
    Hu Yuan-Tai
    Cui Zhi-Jian
    Jiang Shu-Nong
    Yang Jia-Shi
    APPLIED MATHEMATICS AND MECHANICS-ENGLISH EDITION, 2006, 27 (06) : 749 - 755
  • [2] THICKNESS-SHEAR VIBRATION OF CIRCULAR CRYSTAL PLATE IN CYLINDRICAL SHELL AS PRESSURE SENSOR
    胡元太
    崔之健
    蒋树农
    杨嘉实
    AppliedMathematicsandMechanics(EnglishEdition), 2006, (06) : 749 - 755
  • [3] THICKNESS-SHEAR VIBRATIONS OF A CIRCULAR CYLINDRICAL PIEZOELECTRIC SHELL
    YANG, JS
    BATRA, RC
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (01): : 309 - 312
  • [4] Flexoelectric effect on thickness-shear vibration of a rectangular piezoelectric crystal plate
    Zheng, Yang
    Huang, Bin
    Wang, Ji
    MATERIALS RESEARCH EXPRESS, 2021, 8 (11)
  • [5] Thickness-shear vibration of a circular cylindrical ceramic cylinder with unattached electrodes and air gaps
    ZengTao Yang
    JiaShi Yang
    ShaoHua Guo
    Liang Cao
    Science in China Series G: Physics, Mechanics and Astronomy, 2009, 52 : 1423 - 1427
  • [6] A Theoretical Model for Analyzing the Thickness-Shear Vibration of a Circular Quartz Crystal Plate With Multiple Concentric Ring Electrodes
    Zhu, Feng
    Li, Peng
    Dai, Xiaoyun
    Qian, Zhenghua
    Kuznetsova, Iren E.
    Kolesov, Vladimir
    Ma, Tingfeng
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (05) : 1808 - 1818
  • [7] Thickness-shear vibration of a circular cylindrical ceramic cylinder with unattached electrodes and air gaps
    Yang ZengTao
    Yang JiaShi
    Guo ShaoHua
    Cao Liang
    SCIENCE IN CHINA SERIES G-PHYSICS MECHANICS & ASTRONOMY, 2009, 52 (09): : 1423 - 1427
  • [8] Geometric eccentricity effect on thickness-shear vibration of an elliptical flexoelectric crystal plate
    Zheng, Yang
    Sun, Zhenbo
    Huang, Bin
    Guo, Yan
    PHYSICA SCRIPTA, 2023, 98 (08)
  • [9] THICKNESS-SHEAR VIBRATION OF A RECTANGULAR QUARTZ PLATE WITH PARTIAL ELECTRODES
    Huijing He
    Jiashi Yang
    John A. Kosinski
    Ji Wang
    Acta Mechanica Solida Sinica, 2013, 26 (02) : 121 - 128
  • [10] Thickness-Shear Vibration of a Rectangular Quartz Plate with Partial Electrodes
    Huijing He
    Jiashi Yang
    John A. Kosinski
    Ji Wang
    Acta Mechanica Solida Sinica, 2013, 26 : 121 - 128