Topological optimization in hip prosthesis design

被引:0
|
作者
M. Fraldi
L. Esposito
G. Perrella
A. Cutolo
S. C. Cowin
机构
[1] University of Napoli “Federico II”,Department of Structural Engineering (DIST)
[2] University of Napoli “Federico II”,Interdisciplinary Research Centre in Biomaterials (CRIB)
[3] University of California,Department of Bioengineering
[4] University of Napoli “Federico II”,Department of Materials and Production Engineering (DIMP)
[5] The New York Center for Biomedical Engineering,Department of Biomedical and Mechanical Engineering
[6] School of Engineering of the City College,undefined
[7] Graduate School of the City University,undefined
关键词
Topological optimization; Femur prosthesis; Trabecular bone tissue; Stress shielding;
D O I
暂无
中图分类号
学科分类号
摘要
With particular interest on total hip arthroplasty (THA), optimization of orthopedic prostheses is employed in this work to minimize the probability of implant failure or maximize prosthesis reliability. This goal is often identified with the reduction of stress concentrations at the interface between bone and these devices. However, aseptic loosening of the implant is mainly influenced by bone resorption phenomena revealed in some regions of the femur when a prosthesis is introduced. As a consequence, bone resorption appears due to stress shielding, that is to say the decrease of the stress level in the implanted femur caused by the significant load carrying of the prosthesis due to its higher stiffness. A maximum stiffness topological optimization-based (TO) strategy is utilized for non-linear static finite element (FE) analyses of the femur–implant assembly, with the goal of reducing stress shielding in the femur and to furnish guidelines for re-designing hip prostheses. This is accomplished by employing an extreme accuracy for both the three-dimensional reconstruction of the femur geometry and the material properties maps assigned as explicit functions of the local densities.
引用
收藏
页码:389 / 402
页数:13
相关论文
共 50 条
  • [41] RESULTS OF TOTAL HIP PROSTHESIS DESIGN ST GEORGE
    BUCHHOLZ, HW
    NOACK, G
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1973, (95) : 201 - 210
  • [42] Optimization of the interface stiffness in non-cemented hip prosthesis
    Miranda, PS
    Guedes, JM
    Rodrigues, H
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 15 - 20
  • [43] LOOK AT PROSTHESIS-CARTILAGE INTERFACE - DESIGN OF A HIP PROSTHESIS CONTAINING PRESSURE TRANSDUCERS
    CARLSON, CE
    MANN, RW
    HARRIS, WH
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1974, 8 (04): : 261 - 269
  • [44] Multi-objective reliability based design optimization using Kriging surrogate model for cementless hip prosthesis
    Dammak, Khalil
    El Hami, Abdelkhalak
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (12) : 854 - 867
  • [45] DESIGN OF A MAXILLOFACIAL PROSTHESIS BASED ON TOPOLOGY OPTIMIZATION
    Dai, Ning
    Zhu, Jian-Feng
    Zhang, Min
    Meng, Ling-Yin
    Yu, Xiao-Ling
    Zhang, Yi-Hua
    Liu, Bing-Yao
    Zhang, Sen-Lin
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2018, 18 (03)
  • [46] Prosthesis socket design through shape optimization
    Saverio Frillici, Francesco
    Rotini, Federico
    Computer-Aided Design and Applications, 2013, 10 (05): : 863 - 876
  • [47] STRUCTURAL-ANALYSIS CONSIDERATION IN DESIGN OF TOTAL HIP PROSTHESIS
    FORTE, MR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, A 57 (04): : 565 - 565
  • [48] THE DEVELOPMENT OF A PHYSIOLOGICAL HIP-PROSTHESIS - THE INFLUENCE OF DESIGN AND MATERIALS
    VANDERSLOTEN, J
    LABEY, L
    VANAUDEKERCKE, R
    HELSEN, J
    VANDERPERRE, G
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1993, 4 (04) : 407 - 414
  • [49] Evaluation of new hip prosthesis design with finite element analysis
    Talip Çelik
    Yasin Kişioğlu
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 1033 - 1038
  • [50] Application of Topological Optimization to Bridge Design
    Briseghella, B.
    Fenu, L.
    Lan, C.
    Mazzarolo, E.
    Zordan, T.
    JOURNAL OF BRIDGE ENGINEERING, 2013, 18 (08) : 790 - 800