Topological optimization in hip prosthesis design

被引:0
|
作者
M. Fraldi
L. Esposito
G. Perrella
A. Cutolo
S. C. Cowin
机构
[1] University of Napoli “Federico II”,Department of Structural Engineering (DIST)
[2] University of Napoli “Federico II”,Interdisciplinary Research Centre in Biomaterials (CRIB)
[3] University of California,Department of Bioengineering
[4] University of Napoli “Federico II”,Department of Materials and Production Engineering (DIMP)
[5] The New York Center for Biomedical Engineering,Department of Biomedical and Mechanical Engineering
[6] School of Engineering of the City College,undefined
[7] Graduate School of the City University,undefined
关键词
Topological optimization; Femur prosthesis; Trabecular bone tissue; Stress shielding;
D O I
暂无
中图分类号
学科分类号
摘要
With particular interest on total hip arthroplasty (THA), optimization of orthopedic prostheses is employed in this work to minimize the probability of implant failure or maximize prosthesis reliability. This goal is often identified with the reduction of stress concentrations at the interface between bone and these devices. However, aseptic loosening of the implant is mainly influenced by bone resorption phenomena revealed in some regions of the femur when a prosthesis is introduced. As a consequence, bone resorption appears due to stress shielding, that is to say the decrease of the stress level in the implanted femur caused by the significant load carrying of the prosthesis due to its higher stiffness. A maximum stiffness topological optimization-based (TO) strategy is utilized for non-linear static finite element (FE) analyses of the femur–implant assembly, with the goal of reducing stress shielding in the femur and to furnish guidelines for re-designing hip prostheses. This is accomplished by employing an extreme accuracy for both the three-dimensional reconstruction of the femur geometry and the material properties maps assigned as explicit functions of the local densities.
引用
收藏
页码:389 / 402
页数:13
相关论文
共 50 条
  • [1] Topological optimization in hip prosthesis design
    Fraldi, M.
    Esposito, L.
    Perrella, G.
    Cutolo, A.
    Cowin, S. C.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2010, 9 (04) : 389 - 402
  • [2] Design Optimization of a Total Hip Prosthesis for Wear Reduction
    Matsoukas, George
    Kim, Il Yong
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (05):
  • [3] MATHEMATICAL SHAPE OPTIMIZATION OF HIP-PROSTHESIS DESIGN
    HUISKES, R
    BOEKLAGEN, R
    JOURNAL OF BIOMECHANICS, 1989, 22 (8-9) : 793 - &
  • [4] NUMERICAL OPTIMIZATION OF THE DESIGN OF A COATED, CEMENTLESS HIP-PROSTHESIS
    EVANS, SL
    GREGSON, PJ
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (08) : 507 - 510
  • [5] Design and optimization of a new integrated hip and knee prosthesis structure
    Luo, Shengli
    Shu, Xiaolong
    Zhu, Hexiang
    Yu, Hongliu
    ARTIFICIAL ORGANS, 2024, 48 (01) : 50 - 60
  • [6] DESIGN OPTIMIZATION OF PROSTHESIS HIP JOINT USING FEM AND DESIGN OF EXPERIMENT APPROACH
    Ali, Syed Junaid
    Goyal, Ashish
    Dadhich, Manish
    Prajapati, Om Shankar
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2020, 32 (06):
  • [7] Topological Optimization Design for a Multiscale Femoral Prosthesis Model Based on Homogenization Method
    Cheng, Cheng
    Dai, Ning
    Huang, Jie
    Zhuang, Yahong
    Tang, Tao
    Yang, Mengna
    SCIENTIFIC PROGRAMMING, 2022, 2022
  • [8] Design optimization of cementless hip prosthesis coating through functionally graded material
    Hedia, H. S.
    Fouda, N.
    COMPUTATIONAL MATERIALS SCIENCE, 2014, 87 : 83 - 87
  • [9] Design and optimization of a hip disarticulation prosthesis using the remote center of motion mechanism
    Li, Xinwei
    Deng, Zhipeng
    Meng, Qiaoling
    Bai, Shaoping
    Chen, Wenming
    Yu, Hongliu
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (02) : 269 - 281
  • [10] DESIGN OPTIMIZATION OF A PROSTHESIS STEM REINFORCING SHELL IN TOTAL HIP-ARTHROPLASTY
    DEBEUS, AM
    HOELTZEL, DA
    EFTEKHAR, NS
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (03): : 347 - 357