A comparison of four protocols for the immobilization of an aptamer on graphite composite electrodes

被引:1
|
作者
Cristina Ocaña
Manel del Valle
机构
[1] Universitat Autònoma de Barcelona,Sensors and Biosensors Group, Department of Chemistry
来源
Microchimica Acta | 2014年 / 181卷
关键词
Aptamer; Thrombin; Electrochemical impedance spectroscopy; Immobilization; Label-free;
D O I
暂无
中图分类号
学科分类号
摘要
We have performed a comparative study on four protocols for the immobilization of the thrombin aptamer on a graphite-epoxy composite electrode with the aim to identify the most practical method for designing the corresponding impedimetric aptasensor. The protocols included (a) physical adsorption, (b) avidin-biotin affinity interaction, (c) electrochemical activation and covalent bonding via amide groups, and (d) electrochemical grafting using 4-carboxybenzenediazonium coupling. The properties of the sensing surface were probed by electrochemical impedance measurements in the presence of the (ferri/ferro)hexacyanide redox couple. An increase in the interfacial charge transfer resistance (Rct) was noted in all cases after the aptamer-thrombin interaction had occurred. The selectivity of the aptasensor over common serum proteins was also systematically investigated. Physical adsorption resulted in the lowest detection limit of the probe (4.5 pM), while avidin-biotin interaction resulted in highest selectivity and reproducibility exhibiting a 4.9 % relative standard deviation at pM thrombin concentration levels.
引用
收藏
页码:355 / 363
页数:8
相关论文
共 50 条
  • [31] Stripping voltammetry with bismuth modified graphite-epoxy composite electrodes
    Kirgöz, ÜA
    Marín, S
    Pumera, M
    Merkoçi, A
    Alegret, S
    ELECTROANALYSIS, 2005, 17 (10) : 881 - 886
  • [32] HYDROGEN AND OXYGEN EVOLUTION ON GRAPHITE FIBER EPOXY MATRIX COMPOSITE ELECTRODES
    LIPKA, SM
    CAHEN, GL
    STONER, GE
    SCRIBNER, LL
    GILEADI, E
    ELECTROCHIMICA ACTA, 1988, 33 (06) : 753 - 760
  • [33] New composite electrodes made of polypyrrole and graphite: Construction, optimization and characterization
    Dione, G.
    Dieng, M. M.
    Aaron, J. J.
    Cachet, H.
    Cachet, C.
    JOURNAL OF POWER SOURCES, 2007, 170 (02) : 441 - 449
  • [34] Ohmic drop effect on the voltammetric behaviour of graphite + polyethylene composite electrodes
    Navarro-Laboulais, J.
    Trijueque, J.
    Garcia-Jareno, J.J.
    Vicente, F.
    Journal of Electroanalytical Chemistry, 422 (1-2): : 91 - 97
  • [35] Material parameters affecting Li plating in Si/graphite composite electrodes
    Boveleth, Lioba
    Lindner, Adrian
    Menesklou, Wolfgang
    Danner, Timo
    Latz, Arnulf
    ELECTROCHIMICA ACTA, 2024, 506
  • [36] Electrochemical Determination of Adrenaline Using MXene/Graphite Composite Paste Electrodes
    Shankar, S. Sharath
    Shereema, Rayammarakkar M.
    Rakhi, R. B.
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (50) : 43343 - 43351
  • [37] Avidin Epoxy-Graphite Composite Electrodes as Platforms for Genosensing and Aptasensing
    Ocana, Cristina
    Figueras, Cristina
    del Valle, Manel
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (09) : 6669 - 6677
  • [38] Colorimetric determination of lithium-ion mobility in graphite composite electrodes
    Maire, Pascal
    Kaiser, Hermann
    Scheifele, Werner
    Novak, Petr
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 644 (02) : 127 - 131
  • [39] Validation of PVC-graphite composite electrodes for routine analytical work
    Luque, M
    Ríos, A
    Valcárcel, M
    ELECTROANALYSIS, 1999, 11 (15) : 1116 - 1123
  • [40] Methanol Electrooxidation at Electrodes Made of Exfoliated Graphite/Nickel/Palladium Composite
    P. Krawczyk
    T. Rozmanowski
    M. Frankowski
    Catalysis Letters, 2019, 149 : 2307 - 2316