A comparison of four protocols for the immobilization of an aptamer on graphite composite electrodes

被引:1
|
作者
Cristina Ocaña
Manel del Valle
机构
[1] Universitat Autònoma de Barcelona,Sensors and Biosensors Group, Department of Chemistry
来源
Microchimica Acta | 2014年 / 181卷
关键词
Aptamer; Thrombin; Electrochemical impedance spectroscopy; Immobilization; Label-free;
D O I
暂无
中图分类号
学科分类号
摘要
We have performed a comparative study on four protocols for the immobilization of the thrombin aptamer on a graphite-epoxy composite electrode with the aim to identify the most practical method for designing the corresponding impedimetric aptasensor. The protocols included (a) physical adsorption, (b) avidin-biotin affinity interaction, (c) electrochemical activation and covalent bonding via amide groups, and (d) electrochemical grafting using 4-carboxybenzenediazonium coupling. The properties of the sensing surface were probed by electrochemical impedance measurements in the presence of the (ferri/ferro)hexacyanide redox couple. An increase in the interfacial charge transfer resistance (Rct) was noted in all cases after the aptamer-thrombin interaction had occurred. The selectivity of the aptasensor over common serum proteins was also systematically investigated. Physical adsorption resulted in the lowest detection limit of the probe (4.5 pM), while avidin-biotin interaction resulted in highest selectivity and reproducibility exhibiting a 4.9 % relative standard deviation at pM thrombin concentration levels.
引用
收藏
页码:355 / 363
页数:8
相关论文
共 50 条
  • [1] A comparison of four protocols for the immobilization of an aptamer on graphite composite electrodes
    Ocana, Cristina
    del Valle, Manel
    MICROCHIMICA ACTA, 2014, 181 (3-4) : 355 - 363
  • [2] Aptamer-modified pencil graphite electrodes for the impedimetric determination of ochratoxin A
    Gokce, Gultekin
    Ben Aissa, Sondes
    Nemcekova, Katarina
    Catanante, Gaelle
    Raouafi, Noureddine
    Marty, Jean-Louis
    FOOD CONTROL, 2020, 115
  • [3] Immobilization of single stranded deoxyribonucleic acid onto graphite electrodes
    Liu, SH
    Sun, CL
    He, PG
    Fang, YH
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (02) : 130 - 134
  • [4] Comparison of Electron Transfer Properties of the SEI On Graphite Composite and Metallic Lithium Electrodes by SECM at OCP
    Buelter, H.
    Peters, F.
    Schwenzel, J.
    Wittstock, G.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (13) : A7024 - A7036
  • [5] Comparative immobilization of antibodies on modified screen-printed graphite electrodes
    Presnova G.V.
    Rubtsova M.Yu.
    Shumyantseva V.V.
    Bulko T.V.
    Egorov A.M.
    Moscow University Chemistry Bulletin, 2008, 63 (2) : 71 - 74
  • [6] ELECTROCHEMICAL PROPERTIES OF GRAPHITE FIBER EPOXY COMPOSITE ELECTRODES
    NACAMULLI, L
    GILEADI, E
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1983, 13 (01) : 73 - 78
  • [7] On the microelectrode behaviour of graphite-epoxy composite electrodes
    O'Hare, D
    Macpherson, JV
    Willows, A
    ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (03) : 245 - 250
  • [8] Density impact on performance of composite Si/graphite electrodes
    Dufek, Eric J.
    Picker, Michael
    Petkovic, Lucia M.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2016, 46 (03) : 359 - 367
  • [9] Impedance analysis of graphite plus polyethylene and graphite plus epoxy composite electrodes
    NavarroLaboulais, J
    Trijueque, J
    GarciaJareno, JJ
    Vicente, F
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 399 (1-2): : 115 - 120
  • [10] Density impact on performance of composite Si/graphite electrodes
    Eric J. Dufek
    Michael Picker
    Lucia M. Petkovic
    Journal of Applied Electrochemistry, 2016, 46 : 359 - 367