Evaluation of left ventricular ejection fraction from radial long-axis tomography: A new reconstruction algorithm for ECG-gated technetium-99m sestamibi SPECT

被引:0
|
作者
Tsujimura E. [1 ]
Kusuoka H. [1 ]
Uehara T. [1 ]
Fukuchi K. [1 ]
Hasegawa S. [1 ]
Matsuda S. [1 ]
Hashimoto K. [1 ]
Ito Y. [1 ]
Hori M. [2 ]
Nishimura T. [1 ,3 ]
机构
[1] Division of Tracer Kinetics, Biomedical Research Center
[2] First Dept. of Internal Medicine, Osaka University Medical School
[3] Division of Tracer Kinetics, Biomedical Research Center, Osaka University Medical School, Yamada-oka, 2-2, Suita
关键词
ECG-gated Tc-99m MIBI SPECT; Left ventricular ejection fraction; Radial long-axis tomography;
D O I
10.1007/BF03164762
中图分类号
学科分类号
摘要
Radial long-axis tomography can provide views similar to contrast left ventriculography (LVG) including the basal and apical areas of the loft ventricle, not possible in routine short-axis tomography. We applied this method to ECG-gated Tc-99m Sestamibi (MIBI) myocardial SPECT images to estimate the left ventricular ejection fraction (LVEF). Methods: ECG-gated Tc-99m MIBI SPECT was performed with a temporal resolution of 10 frames per R-R interval. LVEF was calculated on the basis of left ventricular volume estimates at end diastole (ED) and end systole (ES) with using an ellipsoid body model. To validate this method, LVEF's derived from ECG-gated Tc-99m MIBI SPECT were compared with those from LVG in 11 patients with coronary artery disease. Results: There was a close linear correlation between LVEF values calculated from Tc-99m MIBI SPECT and those from LVG (r = 0.89, p < 0.001), although the gated SPECT underestimated LVEF compared to LVG. The technique showed excellent reproducibility (intra-observer variability, r = 0.96, p < 0.001; inter-observer variability, r = 0.71, p < 0.005). Conclusion: The radial long-axis tomography technique gives a good estimate of LVEF, in agreement with estimates based on LVG. ECG-gated Tc-99m MIBI SPECT can, therefore, be applicable to assess myocardial perfusion and ventricular function at the same time.
引用
收藏
页码:189 / 193
页数:4
相关论文
共 50 条
  • [31] Automated calculation of left ventricular ejection fraction from gated Tc-99m sestamibi myocardial images - Comparison to quantitative echocardiography
    Zanger, DR
    Bhatnagar, A
    Hausner, E
    Botello, MF
    Nuquist, CE
    Martinez, AI
    Welssman, NJ
    Cerqueira, MD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 98546 - 98546
  • [32] Feasibility of using resting rather than post-stress images for measurement of resting left ventricular systolic function by gated technetium-99m sestamibi SPECT.
    Calnon, DA
    Kastner, RJ
    Smith, WH
    Beller, GA
    Watson, DD
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 43 - 43
  • [33] Assessment of occult left ventricular dysfunction in coronary artery disease patients without prior myocardial infarction by technetium-99m sestamibi myocardial perfusion gated SPECT.
    Yao, SS
    Chandra, P
    Dorbala, S
    Nichols, K
    Depuey, EG
    Rozanski, A
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 87P - 87P
  • [34] Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: A comparison with cine magnetic resonance imaging
    Periyanan Vaduganathan
    Zuo-Xiang He
    G. Wesley Vick
    John J. Mahmarian
    Mario S. Verani
    Journal of Nuclear Cardiology, 1999, 6 : 3 - 10
  • [35] Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: A comparison with cine magnetic resonance imaging
    Vaduganathan, P
    He, ZX
    Vick, GW
    Mahmarian, JJ
    Verani, MS
    JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (01) : 3 - 10
  • [36] Assessing adriamycin-induced early cardiotoxicity by estimating left ventricular ejection fraction using technetium-99m multiple-gated acquisition scan and echocardiography
    Fatima, Nosheen
    Zaman, Maseeh Uz
    Hashmi, Adnan
    Kamal, Shahid
    Hameed, Abid
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (05) : 381 - 385
  • [37] Left ventricular ejection fraction determined by gated perfusion tomography with thallium-201 and Tc-99m sestamibi and by first pass imaging: Effect of depressed left ventricular function
    He, ZX
    Mahmarian, JJ
    Preslar, JS
    Verani, MS
    CIRCULATION, 1997, 96 (08) : 2109 - 2109
  • [38] Determination of left ventricular volume, mass and ejection fraction: comparison of model-based analysis of ECG-gated 99mTc-SPECT and 18F-FDG-PET
    Khorsand, A.
    Gyoengyoesi, M.
    Sochor, H.
    Kletter, K.
    Dudczak, R.
    Maurer, G.
    Porenta, G.
    Graf, S.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S58 - S58
  • [39] Assessment of left ventricular volumes, ejection fraction and mass Comparison of model-based analysis of ECG-gated 99mTc-SPECT and 18F-FDG-PET
    Khorsand, A.
    Gyoengyoesi, M.
    Sochor, H.
    Maurer, G.
    Karanikas, G.
    Dudczak, R.
    Schuster, E.
    Porenta, G.
    Graf, S.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2011, 50 (01): : 9 - 14
  • [40] LEFT-VENTRICULAR EJECTION FRACTION AND VOLUMES CALCULATED FROM DUAL GATED SPECT MYOCARDIAL IMAGING WITH TC-99(M)-MIBI
    KOURIS, K
    ABDELDAYEM, HM
    TAHA, B
    BALLANI, N
    HASSAN, IM
    CONSTANTINIDES, C
    NUCLEAR MEDICINE COMMUNICATIONS, 1992, 13 (09) : 648 - 655