Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study

被引:0
|
作者
Georg Köster
Sabine Rading
机构
[1] Chirurgisch-Orthopädische Fachklinik Lorsch,Abteilung Orthopädische Chirurgie und Traumatologie
关键词
Hip; Revision; Acetabular defects; Oblong cup; Long-term results;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:603 / 608
页数:5
相关论文
共 50 条
  • [1] Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study
    Koester, Georg
    Rading, Sabine
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (05) : 603 - 608
  • [2] Cementless acetabular cup: 6-year follow-up
    Giménez A.
    Llinares T.
    Gil A.
    Journal of Orthopaedics and Traumatology, 2002, 3 (2) : 85 - 87
  • [3] 9-YEAR FOLLOW-UP OF THE CEMENTLESS RING HIP
    ALBRECHTOLSEN, P
    OWENFALKENBERG, T
    BURGAARD, P
    ANDERSEN, PB
    ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (01): : 77 - 80
  • [4] Acetabular revision arthroplasty using so-called jumbo cementless components - An average 7-year follow-up study
    Dearborn, JT
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 2000, 15 (01): : 8 - 15
  • [5] An oblong revision cup for large acetabular defects -: Design rationale and two- to seven-year follow-up
    Köster, G
    Willert, HG
    Köhler, HP
    Döpkens, K
    JOURNAL OF ARTHROPLASTY, 1998, 13 (05): : 559 - 569
  • [6] Revision of a cemented acetabular component to a cementless acetabular component - A ten to fourteen-year follow-up study
    Templeton, JE
    Callaghan, JJ
    Goetz, DD
    Sullivan, PM
    Johnston, RC
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (11): : 1706 - 1711
  • [7] Revision of Failed Total Hip Arthroplasty Acetabular Cups to Porous Tantalum Components A 5-Year Follow-Up Study
    Fernandez-Fairen, Mariano
    Murcia, Antonio
    Blanco, Agustin
    Merono, Antonio
    Murcia, Antonio, Jr.
    Ballester, Jorge
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 865 - 872
  • [8] Acetabular Cup Revision With the Use of the Medial Protrusio Technique at an Average Follow-up of 6.6 Years
    Fabi, David
    Gonzalez, Mark
    Goldstein, Wayne
    Ahmed, Muhammad
    JOURNAL OF ARTHROPLASTY, 2010, 25 (02): : 197 - 202
  • [9] Revision with Cementless Acetabular Components A Concise Follow-up, at a Minimum of Twenty Years, of Previous Reports
    Trumm, Bryan N.
    Callaghan, John J.
    Liu, Steve S.
    Goetz, Devon D.
    Johnston, Richard C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (21): : 2001 - 2004
  • [10] Acetabular Revision Total Hip Arthroplasty Using an Impacted Morselized Allograft and a Cementless Cup Minimum 10-Year Follow-Up
    Lee, Joong-Myung
    Nam, Hee-Tae
    JOURNAL OF ARTHROPLASTY, 2011, 26 (07): : 1057 - 1060