A dual closed-loop control system for mechanical ventilation

被引:43
|
作者
Tehrani F.T. [1 ]
Rogers M. [2 ]
Lo T. [3 ]
Malinowski T. [2 ]
Afuwape S. [2 ]
Lum M. [2 ]
Grundl B. [2 ]
Terry M. [2 ]
机构
[1] Department of Electrical Engineering, California State University, Fullerton, CA 92831
[2] Department of Respiratory Care, Loma Linda University Medical Center, Loma Linda
[3] Medical Intensive Care Unit, Loma Linda University Medical Center, Loma Linda
关键词
Closed-loop control; Mechanical ventilation; Multiple data feedback; Oxygen; Work of breathing;
D O I
10.1023/B:JOCM.0000032744.99885.38
中图分类号
学科分类号
摘要
Objective. Closed-loop mechanical ventilation has the potential to provide more effective ventilatory support to patients with less complexity than conventional ventilation. The purpose of this study was to investigate the effectiveness of an automatic technique for mechanical ventilation. Methods. Two closed-loop control systems for mechanical ventilation are combined in this study. In one of the control systems several physiological data are used to automatically adjust the frequency and tidal volume of breaths of a patient. This method, which is patented under US Patent number 4986268, uses the criterion of minimal respiratory work rate to provide the patient with a natural pattern of breathing. The inputs to the system include data representing CO2 and O2 levels of the patient as well as respiratory compliance and airway resistance. The I:E ratio is adjusted on the basis of the respiratory time constant to allow for effective emptying of the lungs in expiration and to avoid intrinsic positive end expiratory pressure (PEEP). This system is combined with another closed-loop control system for automatic adjustment of the inspired fraction of oxygen of the patient. This controller uses the feedback of arterial oxygen saturation of the patient and combines a rapid stepwise control procedure with a proportional-integral-derivative (PID) control algorithm to automatically adjust the oxygen concentration in the patient's inspired gas. The dual closed-loop control system has been examined by using mechanical lung studies, computer simulations and animal experiments. Results. In the mechanical lung studies, the ventilation controller adjusted the breathing frequency and tidal volume in a clinically appropriate manner in response to changes in respiratory mechanics. The results of computer simulations and animal studies under induced disturbances showed that blood gases were returned to the normal physiologic range in less than 25 s by the control system. In the animal experiments under steady-state conditions, the maximum standard deviations of arterial oxygen saturation and the end-tidal partial pressure of CO2 were ± 1.76% and ± 1.78 mmHg, respectively. Conclusion. The controller maintained the arterial blood gases within normal limits under steady-state conditions and the transient response of the system was robust under various disturbances. The results of the study have showed that the proposed dual closed-loop technique has effectively controlled mechanical ventilation under different test conditions. © 2004 Kluwer Academy Publishers.
引用
收藏
页码:111 / 129
页数:18
相关论文
共 50 条
  • [21] The rapid development of a closed-loop control system
    Ding, ZQ
    Ling, KV
    Goh, KM
    [J]. INTERNATIONAL JOURNAL OF SOFTWARE ENGINEERING AND KNOWLEDGE ENGINEERING, 2005, 15 (02) : 325 - 331
  • [22] MICROPOSITIONER IN A CLOSED-LOOP CONTROL-SYSTEM
    CONNOR, GI
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (02) : 114 - 119
  • [23] Testing of a reactor control system in closed-loop
    Petruzela, Ivan
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 314 - 317
  • [24] On closed-loop vibrational control of underactuated mechanical systems
    Sevak Tahmasian
    Craig A. Woolsey
    [J]. Nonlinear Dynamics, 2022, 108 : 329 - 347
  • [25] Closed-loop identification for motion control system
    Zhou, Lei
    Li, Jiangang
    Sheng, Jun
    Cao, Jun
    Li, Zexiang
    [J]. 2010 8TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2010, : 477 - 480
  • [26] A closed-loop adaptive system for command and control
    de Greef, Tjerk
    Arciszewski, Henryk
    [J]. FOUNDATIONS OF AUGMENTED COGNITION, PROCEEDINGS, 2007, 4565 : 276 - +
  • [27] Embedded System Design in Closed-loop Active Flow Control Embedded System Design in Closed-loop Active Flow Control
    Hu, Qiyang
    Wu, Naiming
    Ren, Jia
    Liu, Chang
    [J]. PROCEEDINGS OF THE 2015 JOINT INTERNATIONAL MECHANICAL, ELECTRONIC AND INFORMATION TECHNOLOGY CONFERENCE (JIMET 2015), 2015, 10 : 880 - 883
  • [28] Closed loop mechanical ventilation
    Wysocki, Marc
    Jouvet, Philippe
    Jaber, Samir
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2014, 28 (01) : 49 - 56
  • [29] Closed loop mechanical ventilation
    Marc Wysocki
    Philippe Jouvet
    Samir Jaber
    [J]. Journal of Clinical Monitoring and Computing, 2014, 28 : 49 - 56
  • [30] Dual-Rate Control System Extension Using the Null Space of a Closed-Loop System
    Yasui, Ryota
    Kawaguchi, Natsuki
    Sato, Takao
    Araki, Nozomu
    Konishi, Yasuo
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (01) : 135 - 139