Can vortices in the flow across mechanical heart valves contribute to cavitation?

被引:0
|
作者
I. Avrahami
M. Rosenfeld
S. Einav
M. Eichler
H. Reul
机构
[1] Tel Aviv University,Faculty of Engineering
[2] Helmholtz Institute,undefined
关键词
Mechanical heart valves; Flow field; Cavitation; Vortices; Navier-Stokes equations; CFD;
D O I
暂无
中图分类号
学科分类号
摘要
Cavitation in mechanical heart valves is traditionally attributed to the hammer effect and to squeeze and clearance flow occurring at the moment of valve closure. In the present study, an additional factor is considered—the contribution of vortex flow. Using a computational fluid dynamics analysis of a 2D model of a tilting disk mitral valve, we demonstrate that vortices may form in the vicinity of the inflow side of the valve. These vortices roll up from shear layers emanating from the valve tips during regurgitation. A significant decrease in the pressure at the centre of the vortices is found. The contribution of the vortex to the total pressure drop at the instant of closure is of the order of 70 mmHg. Adding this figure to the other pressure drop sources that reach 670 mmHg, it might be that this is the deciding factor that causes the drop in blood pressure below vapour pressure. The total pressure drop near the upper tip (750 mmHg) is larger than near the lower tip (670 mmHg), indicating a preferential location for cavitation inception, in agreement with existing experimental findings.
引用
收藏
页码:93 / 97
页数:4
相关论文
共 50 条
  • [21] A study on the mechanism for cavitation in the mechanical heart valves with an electrohydraulic total artificial heart
    Lee, H
    Tsukiya, T
    Homma, A
    Kamimura, T
    Tatsumi, E
    Taenaka, Y
    Kitamura, S
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2004, 47 (04) : 1043 - 1048
  • [22] Cavitation phenomenon in monoleaflet mechanical heart valves with electrohydraulic total artificial heart
    Lee, H. (hslee@ri.ncvc.go.jp), 1600, Wichtig Editore s.r.l. (27):
  • [23] Cavitation phenomena in mechanical heart valves: the role of squeeze flow velocity and contact area on cavitation initiation between two impinging rods
    Lim, WL
    Chew, YT
    Low, HT
    Foo, WL
    JOURNAL OF BIOMECHANICS, 2003, 36 (09) : 1269 - 1280
  • [24] EXPERIMENTAL STUDY REGARDING THE OCCURRENCE OF CAVITATION IN MONOLEAFLET MECHANICAL HEART VALVES
    Giurgea, Corina
    EXPERIMENTAL FLUID MECHANICS 2006, PROCEEDINGS, 2006, : 62 - 72
  • [25] The effect of dissolved carbon dioxide on cavitation intensity in mechanical heart valves
    Herbertson, LH
    Manning, KB
    Reddy, V
    Fontaine, AA
    Tarbell, JM
    Deutsch, S
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (06): : 835 - 842
  • [26] Scaling of mechanical heart valves for cavitation inception: Observation and acoustic detection
    Chahine, GL
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (02): : 207 - 215
  • [27] Squeeze flow measurements in mechanical heart valves
    Lo, Chi-Wen
    Lu, Po-Chien
    Liu, Jia-Shing
    Li, Chi-Pei
    Hwang, Ned H.
    ASAIO JOURNAL, 2008, 54 (02) : 156 - 162
  • [28] Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: Cavitation and closing velocity
    Lee, Hwansung
    Homma, Akihiko
    Taenaka, Yoshiyuki
    ARTIFICIAL ORGANS, 2007, 31 (07) : 532 - 537
  • [29] Can mechanical heart valves perform similarly to tissue valves? An in vitro study
    Goode, Dylan
    Scotten, Lawrence
    Siegel, Rolland
    Mohammadi, Hadi
    JOURNAL OF BIOMECHANICS, 2024, 174
  • [30] Can regurgitant flow damage the left atrial endothelium in patients with prosthetic mechanical heart valves?
    Milo, S
    Zarandi, M
    Gutfinger, C
    Gharib, M
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (03): : 344 - 352