Near-Infrared Spectroscopic Monitoring During Cardiopulmonary Exercise Testing Detects Anaerobic Threshold

被引:0
|
作者
Rohit P. Rao
Michael J. Danduran
Rohit S. Loomba
Jennifer E. Dixon
George M. Hoffman
机构
[1] Phoenix Children’s Hospital,Sections of Cardiology and Critical Care
[2] Medical College of Wisconsin,Department of Pediatrics
[3] Medical College of Wisconsin,Department of Anesthesia, Section of Pediatric Anesthesia
[4] Children’s Hospital of Wisconsin,Herma Heart Center
来源
Pediatric Cardiology | 2012年 / 33卷
关键词
NIRS; Cardiopulmonary exercise testing; Anaerobic threshold; Noninvasive monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
Cardiopulmonary exercise testing (CPET) provides assessment of the integrative responses involving the pulmonary, cardiovascular, and skeletal muscle systems. Application of exercise testing remains limited to children who are able to understand and cooperate with the exercise protocol. Near-infrared spectroscopy (NIRS) provides a noninvasive, continuous method to monitor regional tissue oxygenation (rSO2). Our specific aim was to predict anaerobic threshold (AT) during CPET noninvasively using two-site NIRS monitoring. Achievement of a practical noninvasive technology for estimating AT will increase the compatibility of CPET. Patients without structural or acquired heart disease were eligible for inclusion if they were ordered to undergo CPET by a cardiologist. Data from 51 subjects was analyzed. The ventilatory anaerobic threshold (VAT) was computed on \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ {\text{V}}_{{{\text{CO}}_{2} }} $$\end{document} and respiratory quotient post hoc using the standard V-slope method. The inflection points of the regional rSO2 time-series were identified as the noninvasive regional NIRS AT for each of the two monitored regions (cerebral and kidney). AT calculation made using an average of kidney and brain NIRS matched the calculation made by VAT for the same patient. Two-site NIRS monitoring of visceral organs is a predictor of AT.
引用
收藏
页码:791 / 796
页数:5
相关论文
共 50 条
  • [41] Measurement of cerebral blood flow during cardiopulmonary bypass with near-infrared spectroscopy
    Roberts, IG
    Fallon, P
    Kirkham, FJ
    Kirshbom, PM
    Cooper, CE
    Elliott, MJ
    Edwards, AD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (01): : 94 - 102
  • [42] Utility and Limitations of Near-Infrared Spectroscopy during Cardiopulmonary Bypass in a Piglet Model
    Takahiko Sakamoto
    Richard A Jonas
    Ulrich A Stock
    Shin'Ichi Hatsuoka
    Mark Cope
    Roger J Springett
    Georg Nollert
    Pediatric Research, 2001, 49 : 770 - 776
  • [43] CEREBRAL HEMODYNAMICS DURING CARDIOPULMONARY BYPASS IN CHILDREN USING NEAR-INFRARED SPECTROSCOPY
    FALLON, P
    ROBERTS, I
    KIRKHAM, FJ
    ELLIOTT, MJ
    LLOYDTHOMAS, A
    MAYNARD, R
    EDWARDS, AD
    ANNALS OF THORACIC SURGERY, 1993, 56 (06): : 1473 - 1477
  • [44] Utility and limitations of near-infrared spectroscopy during cardiopulmonary bypass in a piglet model
    Sakamoto, T
    Jonas, RA
    Stock, UA
    Hatsuoka, S
    Cope, M
    Springett, RJ
    Nollert, G
    PEDIATRIC RESEARCH, 2001, 49 (06) : 770 - 776
  • [45] Evaluation of cerebral circulation during cardiopulmonary bypass using near-infrared spectroscopy
    Ohata T.
    Sawa Y.
    Ohtake S.
    Nishimura M.
    Hirata N.
    Kagisaki K.
    Taketani S.
    Yamaguchi T.
    Matsuda H.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 1998, 46 (7): : 603 - 609
  • [46] NONINVASIVE DETECTION OF THE ANAEROBIC THRESHOLD DURING COMPUTER-CONTROLLED EXERCISE TESTING
    TALBOT, TL
    SCHUETTE, WH
    TIPTON, HW
    THIBAULT, LE
    BROWN, FL
    WINSLOW, RM
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (06) : 579 - 584
  • [47] VALUE OF MEASURING ANAEROBIC THRESHOLD DURING RADIONUCLIDE EXERCISE TESTING IN AORTIC REGURGITATION
    BOUCHER, CA
    KANAREK, DJ
    PHILLIPS, HR
    LIBERTHSON, RR
    OKADA, RD
    BLOCK, PC
    STRAUSS, HW
    POHOST, GM
    AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (02): : 473 - 473
  • [48] ANAEROBIC THRESHOLD AND ANASTOMOTIC LEAK-PREDICTIVE CAPACITY OF CARDIOPULMONARY EXERCISE TESTING IN A DISTRICT GENERAL HOSPITAL
    Stewart, D. G. J.
    Murray, H.
    Rutherfoord-Jones, N.
    INTENSIVE CARE MEDICINE, 2011, 37 : S165 - S165
  • [49] OCCLUSION PRESSURE - ANOTHER INDEX OF ANAEROBIC THRESHOLD DURING INCREMENTAL EXERCISE TESTING
    SORBINI, CA
    GRASSI, V
    TANTUCCI, C
    BOSCHETTI, E
    IRCS MEDICAL SCIENCE-BIOCHEMISTRY, 1981, 9 (09): : 818 - 819
  • [50] Near-infrared monitoring of tissue oxygenation during application of lower body pressure at rest and during dynamical exercise in humans
    Nishiyasu, T
    Tan, N
    Kondo, N
    Nishiyasu, M
    Ikegami, H
    ACTA PHYSIOLOGICA SCANDINAVICA, 1999, 166 (02): : 123 - 130