Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups

被引:0
|
作者
Feng Wu
Ting Huang
Yangjian Hu
Xin Yang
Yuejun Ouyang
Qingji Xie
机构
[1] Hunan Normal University,Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education), College of Chemistry and Chemical Engineering
[2] Huaihua College,Chemistry and Material Engineering Department
来源
Microchimica Acta | 2016年 / 183卷
关键词
Chemical sensor; Anodization; Cyclic voltammetry; Differential pulse voltammetry; Ascorbic acid; Dopamine; Uric acid; Urine analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCEox). Next, an imidazolium alkoxysilane (ImAS) is covalently tethered to the surface of the GCEox via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and π-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCEox by CV yields electroreduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at −50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 μM for AA, from 20 to 490 μM for UA, and from 0.1 to 5 μM and from 5 μM to 200 μM (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 μM, 5 μM and 0.03 μM. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine.
引用
收藏
页码:2539 / 2546
页数:7
相关论文
共 50 条
  • [41] Simultaneous Determination of Dopamine, Uric Acid and Ascorbic Acid with CTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, B. E. Kumara
    Chandra, Umesh
    Manjunatha, J. G.
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (04): : 592 - 601
  • [42] Synergistic Effect of Graphene and Multiwalled Carbon Nanotubes on a Glassy Carbon Electrode for Simultaneous Determination of Uric Acid and Dopamine in the Presence of Ascorbic Acid
    He, Sijing
    Yu, Yanyan
    Chen, Zuanguang
    Shi, Qiujia
    Zhang, Lin
    ANALYTICAL LETTERS, 2015, 48 (02) : 248 - 258
  • [43] Ultrasensitive Reduced Graphene Oxide-Poly(Procion)/Gold Nanoparticles Modified Glassy Carbon Electrode for Selective and Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid
    Edris, Nusiba Mohammed Modawe Alshik
    Abdullah, Jaafar
    Kamaruzaman, Sazlinda
    Sulaiman, Yusran
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (08) : B664 - B672
  • [44] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 359 - 365
  • [45] Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Li, Haijuan
    Niu, Wenxin
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 940 - 943
  • [46] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Nitrogen Doped Carbon Sphere Modified Glassy Carbon Electrode
    Ye, Fucheng
    Wen, Zubiao
    Wu, Hongfu
    Wang, Chunyan
    Qian, Yong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1136 - 1143
  • [47] Nano-Cu/PSA III modified glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhang, Lei
    Yuan, Wen-Juan
    Hou, Bao-Qin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 689 : 135 - 141
  • [48] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid, at a Graphene Paste Electrode Modified with Functionalized Graphene Sheets
    Parvin, Mohammad Hadi
    ELECTROANALYSIS, 2015, 27 (06) : 1394 - 1402
  • [49] Simultaneous Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid at the Indole-3-Carboxaldehyde Modified Glassy Carbon Electrode
    Deletioglu, Didem
    Hasdemir, Erdogan
    Solak, Ali O.
    CURRENT ANALYTICAL CHEMISTRY, 2010, 6 (03) : 203 - 208
  • [50] Simultaneous Voltammetric Determination of Norepinephrine, Ascorbic Acid and Uric Acid by TTAB Modified Carbon Paste Electrode
    Shankar, S. Sharath
    Swamy, Bahaddurghatta E. Kumara
    Mahanthesha, Kurangalara R.
    Vishwanatha, Chandrashekar C.
    Kumar, Mohan
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (05): : 555 - 573