Scanning laser polarimetry, retinal nerve fiber layer photography, and perimetry in the diagnosis of glaucomatous nerve fiber defects

被引:0
|
作者
S. Kremmer
H. Dede Ayertey
J. M. Selbach
K.-P. Steuhl
机构
[1] University Eye Hospital,
[2] Hufelandstrasse 55,undefined
[3] 45122 Essen,undefined
[4] Germany e-mail: stephan.kremmer@uni-essen.de Tel.: +49-201-7232371 Fax: +49-201-7235917,undefined
关键词
Glaucoma; Retinal Nerve Fiber Layer; Glaucoma Patient; Glaucomatous Damage; Automate Perimetry;
D O I
暂无
中图分类号
学科分类号
摘要
Background: Retinal nerve fiber layer defects are part of early glaucomatous damage. In the present study, we compared the ability of retinal nerve fiber layer photography (NFP) and scanning laser polarimetry (SLP) to detect nerve fiber layer defects in glaucoma patients. Methods: Besides ophthalmological standard examinations, we performed NFP (Zeiss Ikon fundus camera 30°, green filter), SLP (GDx, 1.0.14 and 2.0.09, LDT) and automated perimetry (Oculus, Twinfield, 30°) in 150 glaucoma patients [74 with primary open-angle glaucoma (POAG) and 76 with normal-tension glaucoma (NTG)]. The perimetric results were evaluated according to a modified Aulhorn classification. NFP and SLP were graded according to Quigley. Results: In POAG, 42% of NFP and 5% of SLP were not evaluable. In NTG, 24% of NFP and 4% of SLP were not evaluable. In POAG, NFP and SLP revealed a direct agreement in 54.5%, and in NTG, 55%; there was a small dif-ference of one stage in 39.5% (POAG) and 41% (NTG). In POAG, NFP / SLP showed agreement with perimetric results in 35%/30% of cases and differences of one stage in 56%/58%. In NTG, NFP / SLP agreed with perimetry in 52%/48% of cases and differed by only one stage in 32%/39%. Larger deviations were found in less than 13% of the cases. Conclusions: NFP and SLP mostly showed good agreement or little deviation as to grading of nerve fiber layer damage. In clinical use, SLP has advantages over NFP because a higher rate of good-quality images can be obtained and pupils do not have to be dilated. Additionally, SLP measurements provide quantitative data and a large normative data base exists.
引用
收藏
页码:922 / 926
页数:4
相关论文
共 50 条
  • [41] Scanning laser polarimetry of the retinal nerve fiber layer in perimetrically unaffected eyes of glaucoma patients
    Reus, NJ
    Lemij, HG
    OPHTHALMOLOGY, 2004, 111 (12) : 2199 - 2203
  • [42] The Effect of Atypical Birefringence Patterns on Retinal Nerve Fiber Layer Measurements With Scanning Laser Polarimetry
    Qiu, Kun Liang
    Huang, Qu Qiang
    Zhang, Ming Zhi
    JOURNAL OF GLAUCOMA, 2010, 19 (03) : 221 - 221
  • [43] Normal retinal nerve fiber layer thickness in the peripapillary region measured by scanning laser polarimetry
    Iester, M
    Mermoud, A
    JOURNAL OF GLAUCOMA, 2001, 10 (03) : 170 - 176
  • [44] Thickness of the retinal nerve fiber layer in amblyopic and normal eyes: A scanning laser polarimetry study
    Baddini-Caramelli, C
    Hatanaka, M
    Polati, M
    Umino, AT
    Susanna-Junior, R
    JOURNAL OF AAPOS, 2001, 5 (02): : 82 - 84
  • [45] DIABETIC CHANGE IN RETINAL NERVE-FIBER LAYER THICKNESS EVALUATED BY SCANNING LASER POLARIMETRY
    IDO, T
    HAYAKAWA, T
    INAZUMI, K
    CHI, Q
    TOMITA, G
    KITAZAWA, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S482 - S482
  • [46] Retinal nerve fiber layer measurement repeatability in scanning laser polarimetry with enhanced corneal compensation
    Mai, The Anh
    Reus, Nicolaas J.
    Lemij, Hans G.
    JOURNAL OF GLAUCOMA, 2008, 17 (04) : 269 - 274
  • [47] Retinal nerve fiber layer measurements using scanning laser polarimetry after photorefractive keratectomy
    Vetrugno, M
    Maino, A
    Valenzano, E
    Cardia, L
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2000, 10 (02) : 137 - 143
  • [48] Assessment of nerve fiber layer in diabetic patients with scanning laser polarimetry
    S Özdek
    Y H Lonneville
    M Önol
    I Yetkin
    B B Hasanreisoğlu
    Eye, 2002, 16 : 761 - 765
  • [49] Assessment of nerve fiber layer in diabetic patients with scanning laser polarimetry
    Özdek, S
    Lonneville, Y
    Önol, M
    Yetkin, I
    Hasanreisoglu, B
    EYE, 2002, 16 (06) : 761 - 765
  • [50] Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes
    Ara, Mirian
    Ferreras, Antonio
    Pajarin, Ana B.
    Calvo, Pilar
    Figus, Michele
    Frezzotti, Paolo
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015