The Placement of Skin Surface Markers for Non-Invasive Measurement of Scapular Kinematics Affects Accuracy and Reliability

被引:0
|
作者
Douglas A. Bourne
Anthony M. Choo
William D. Regan
Donna L. MacIntyre
Thomas R. Oxland
机构
[1] University of British Columbia and Vancouver Coastal Health Research Institute,Orthopaedic and Injury Biomechanics Group, Departments of Orthopaedics and Mechanical Engineering
[2] University of British Columbia,Division of Upper Extremity Reconstruction, Department of Orthopaedics
[3] University of British Columbia,Department of Physical Therapy
来源
关键词
Scapula; Kinematics; Skin markers; Biomechanics;
D O I
暂无
中图分类号
学科分类号
摘要
Abnormal scapular movement is widely believed to be an important factor in clinical pathology of the shoulder joint complex. Validated non-invasive techniques for measuring scapular movement have been developed, but the effect of marker placement on accuracy is unknown. The objective of this study was to determine the accuracy and reliability of different groupings of markers to achieve the best accuracy and reliability for measuring scapular kinematics. Eight healthy young adult subjects were recruited. An optoelectronic marker grid was applied to the skin overlying the scapula. Two bone pins with optoelectronic marker carriers were inserted into the scapula. The accuracy of six surface marker configurations was determined by comparing the measured kinematics with scapular bone pins (the gold standard). Four humeral movements were tested: glenohumeral abduction, glenohumeral horizontal adduction, hand behind back, and forward reaching. All three rotations had a significant difference in the accuracy of the patches (p = 0.04 to p < 0.0001). For posterior tipping there was a significant effect of movement (p = 0.003) and a significant interaction (p < 0.0001). There was also a significant interaction for external rotation (p = 0.001). The marker grouping with the largest cranio-caudal spread had the highest accuracy for measuring posterior tilting (RMS 1.9°). Markers closer to the scapular spine were more accurate for tracking external rotation (RMS 2.0°) while an intermediate grouping of markers were most accurate for quantifying upward rotation (RMS 1.9°). The reliability between days ranged between 3.8° and 7.5° (based on RMS difference between trials) and there was a significant interaction between patch and movement (p < 0.0001). Intraclass correlation coefficients show moderate to good agreement for most arm movements and scapular rotations. Thus, there exists distinct optimal configurations of non-invasive marker locations for accurately measuring scapular kinematics.
引用
收藏
页码:777 / 785
页数:8
相关论文
共 50 条
  • [1] The Placement of Skin Surface Markers for Non-Invasive Measurement of Scapular Kinematics Affects Accuracy and Reliability
    Bourne, Douglas A.
    Choo, Anthony M.
    Regan, William D.
    MacIntyre, Donna L.
    Oxland, Thomas R.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (02) : 777 - 785
  • [2] RELIABILITY OF A NON-INVASIVE MEASUREMENT OF SCAPULAR POSITION
    MCDONNELL, MK
    MUELLER, M
    ONUFER, MF
    SHIFFLER, M
    [J]. PHYSICAL THERAPY, 1984, 64 (05): : 748 - 748
  • [3] Non-invasive measurement of the kinematics of the clavicle
    Marchese, SS
    Johnson, GR
    [J]. PROCEEDINGS OF THE THIRD CONFERENCE OF THE INTERNATIONAL SHOULDER GROUP, 2001, : 61 - 65
  • [4] Blinking kinematics description through non-invasive measurement
    Perez, Jorge
    Espinosa, Julian
    Domenech, Begona
    Mas, David
    Illueca, Carlos
    [J]. JOURNAL OF MODERN OPTICS, 2011, 58 (19-20) : 1857 - 1863
  • [5] Accuracy of non-invasive intracranial pressure measurement
    Seddighi, Amir Saied
    Zadeh, Alireza Moqareh
    Seddighi, Afsoun
    Zali, Alireza
    [J]. CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2012, 7 (02): : 169 - 175
  • [6] Accuracy and reliability of three methods of recording scapular motion using reflective skin markers
    Brochard, S.
    Lempereur, M.
    Remy-Neris, O.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H1) : 100 - 105
  • [7] Predictors of Accuracy of Non-Invasive Markers of Hepatic Fibrosis
    Martin, Jason
    Yopp, Adam
    Singal, Amit
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 : S199 - S200
  • [8] Clinical Assessment of the Accuracy of ICP Non-invasive Measurement
    Ragauskas, A.
    Sunokas, R.
    Zakelis, R.
    Matijosaitis, V.
    [J]. ELEKTRONIKA IR ELEKTROTECHNIKA, 2010, (08) : 31 - 34
  • [9] Accuracy and reliability of non-invasive cardiac output: The future in cardiology?
    Faddy, S
    Boland, J
    Muller, DWM
    [J]. COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 251 - 253
  • [10] A non-invasive measurement of tongue surface temperature
    Lv, Cong
    Wang, Xinmiao
    Chen, Jianshe
    Yang, Ni
    Fisk, Ian
    [J]. FOOD RESEARCH INTERNATIONAL, 2019, 116 : 499 - 507