Mobile-bearing prosthesis did not improve mid-term clinical results of total knee arthroplasty

被引:0
|
作者
Shuichi Matsuda
Hideki Mizu-uchi
Shingo Fukagawa
Hiromasa Miura
Ken Okazaki
Hideo Matsuda
Yukihide Iwamoto
机构
[1] Kyushu University,Department of Orthopaedic Surgery, Faculty of Medical Sciences
[2] Matsuda Orthopaedic Clinic,undefined
关键词
Total knee arthroplasty; Mobile-bearing; Computed tomography; Rotational alignment; Flexion angle;
D O I
暂无
中图分类号
学科分类号
摘要
A prospective study was performed to compare the clinical and radiological results of mobile- and fixed-bearing total knee arthroplasty with specific attention to rotational alignment and range of motion. Sixty-one knees were assigned to total knee arthroplasty with either the NexGen LPS Flex fixed-bearing or with the NexGen LPS Flex mobile-bearing prosthesis. Postoperatively, knees were compared with regard to range of motion, clinical score, and radiographic findings. Rotational alignment of the femoral and tibial components was evaluated by computed tomography. The median follow-up period was 5.9 years (range 2.1–8.8 years). Median postoperative Knee Society scores were 99 points (68–100) for the fixed-bearing group and 100 points (66–100) for the mobile-bearing group (n.s.). The median postoperative flexion angles of 120° (90°–150°) for the fixed-bearing group and 125° (90°–145°) for the mobile-bearing group were not significantly different from each other (n.s.). No knee required revision surgery due to wear of polyethylene or loosening of the component in either group. Computed tomography showed that 11 knees had rotational mismatches of more than 10° between the femoral and tibial components, but no significant difference was found in the postoperative extension and flexion angles or in the clinical score between the two treatment groups. Using the identical design for both fixed- and mobile-bearing prostheses, this prospective, randomized study did not show any clinical advantages of the mobile-bearing knee. Analysis of rotational alignment by CT scan did not reveal a particular advantage of the self-aligning mechanism of mobile-bearing implants.
引用
收藏
页码:1311 / 1316
页数:5
相关论文
共 50 条
  • [41] Secondary resurfacing of the patella in mobile-bearing total knee arthroplasty
    Mockford, BJ
    Beverland, DE
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 898 - 902
  • [42] The kinematics of fixed- and mobile-bearing total knee arthroplasty
    Most, E
    Li, G
    Schule, S
    Sultan, P
    Park, SE
    Zayontz, S
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) : 197 - 207
  • [43] Mobile-Bearing Total Knee Arthroplasty A Meta-Analysis
    Carothers, Joshua T.
    Kim, Raymond H.
    Dennis, Douglas A.
    Southworth, Carleton
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04): : 537 - 542
  • [44] Successful biologic fixation with mobile-bearing total knee arthroplasty
    Tarkin, IS
    Bridgeman, JT
    Jardon, OM
    Garvin, KL
    JOURNAL OF ARTHROPLASTY, 2005, 20 (04): : 481 - 486
  • [45] Femoral component rotation in mobile-bearing total knee arthroplasty
    Boldt, J. G.
    Stiehl, J. B.
    Munzinger, U.
    Beverland, D.
    Keblish, P. A.
    KNEE, 2006, 13 (04): : 284 - 289
  • [46] No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study
    Deroche, Etienne
    Batailler, Cecile
    Shatrov, Jobe
    Gunst, Stanislas
    Servien, Elvire
    Lustig, Sebastien
    SICOT-J, 2023, 9 : 335 - 340
  • [47] Anterior-Posterior Glide Mobile-Bearing Total Knee Arthroplasty Complications Related to Prosthesis Design
    Hwang, Bo-Hyun
    Lee, Woo-Suk
    Park, Kwan-Kyu
    Yang, Ick-Hwan
    Han, Chang-Dong
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1438 - 1444
  • [48] No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty
    Ruud P. van Hove
    Richard M. Brohet
    Barend J. van Royen
    Peter A. Nolte
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1833 - 1840
  • [49] Mobile-bearing unicompartmental knee arthroplasty
    Keblish, PA
    Briard, JL
    JOURNAL OF ARTHROPLASTY, 2004, 19 (07): : 87 - 94
  • [50] No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty
    van Hove, Ruud P.
    Brohet, Richard M.
    van Royen, Barend J.
    Nolte, Peter A.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (06) : 1833 - 1840