Mobile-bearing prosthesis did not improve mid-term clinical results of total knee arthroplasty

被引:0
|
作者
Shuichi Matsuda
Hideki Mizu-uchi
Shingo Fukagawa
Hiromasa Miura
Ken Okazaki
Hideo Matsuda
Yukihide Iwamoto
机构
[1] Kyushu University,Department of Orthopaedic Surgery, Faculty of Medical Sciences
[2] Matsuda Orthopaedic Clinic,undefined
关键词
Total knee arthroplasty; Mobile-bearing; Computed tomography; Rotational alignment; Flexion angle;
D O I
暂无
中图分类号
学科分类号
摘要
A prospective study was performed to compare the clinical and radiological results of mobile- and fixed-bearing total knee arthroplasty with specific attention to rotational alignment and range of motion. Sixty-one knees were assigned to total knee arthroplasty with either the NexGen LPS Flex fixed-bearing or with the NexGen LPS Flex mobile-bearing prosthesis. Postoperatively, knees were compared with regard to range of motion, clinical score, and radiographic findings. Rotational alignment of the femoral and tibial components was evaluated by computed tomography. The median follow-up period was 5.9 years (range 2.1–8.8 years). Median postoperative Knee Society scores were 99 points (68–100) for the fixed-bearing group and 100 points (66–100) for the mobile-bearing group (n.s.). The median postoperative flexion angles of 120° (90°–150°) for the fixed-bearing group and 125° (90°–145°) for the mobile-bearing group were not significantly different from each other (n.s.). No knee required revision surgery due to wear of polyethylene or loosening of the component in either group. Computed tomography showed that 11 knees had rotational mismatches of more than 10° between the femoral and tibial components, but no significant difference was found in the postoperative extension and flexion angles or in the clinical score between the two treatment groups. Using the identical design for both fixed- and mobile-bearing prostheses, this prospective, randomized study did not show any clinical advantages of the mobile-bearing knee. Analysis of rotational alignment by CT scan did not reveal a particular advantage of the self-aligning mechanism of mobile-bearing implants.
引用
收藏
页码:1311 / 1316
页数:5
相关论文
共 50 条
  • [1] Mobile-bearing prosthesis did not improve mid-term clinical results of total knee arthroplasty
    Matsuda, Shuichi
    Mizu-uchi, Hideki
    Fukagawa, Shingo
    Miura, Hiromasa
    Okazaki, Ken
    Matsuda, Hideo
    Iwamoto, Yukihide
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (10) : 1311 - 1316
  • [2] Mid-term results with a highly congruous mobile-bearing knee prosthesis
    Lemaire, Roger G.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (02) : 170 - 180
  • [3] Mid-term results with a highly congruous mobile-bearing knee prosthesis
    Roger G. Lemaire
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 170 - 180
  • [4] Mid-term outcomes of mobile-bearing lateral unicompartmental knee arthroplasty
    Fornell, S.
    Prada, E.
    Barrena, P.
    Garcia-Mendoza, A.
    Borrego, E.
    Domecq, G.
    [J]. KNEE, 2018, 25 (06): : 1206 - 1213
  • [5] The effect of BMI on the mid-term clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Liu, Yikai
    Gao, Huanshen
    Li, Tao
    Zhang, Zian
    Zhang, Haining
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [6] The effect of BMI on the mid-term clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Yikai Liu
    Huanshen Gao
    Tao Li
    Zian Zhang
    Haining Zhang
    [J]. BMC Musculoskeletal Disorders, 23
  • [7] Fixed-bearing versus mobile-bearing total knee arthroplasty:: A prospective randomised, clinical and radiological study with mid-term results at 7 years
    Laedermann, A.
    Luebbeke, A.
    Stern, R.
    Riand, N.
    Fritschy, D.
    [J]. KNEE, 2008, 15 (03): : 206 - 210
  • [8] Mobile-bearing total knee prosthesis
    Sansone, V
    Malchér, MD
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (06): : 678 - 685
  • [9] Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses
    D. Biau
    M. M. Mullins
    T. Judet
    P. Piriou
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 927 - 933
  • [10] Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses
    Biau, D.
    Mullins, M. M.
    Judet, T.
    Piriou, P.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (10) : 927 - 933