Quantitative Tissue Blood Flow Measurement of the Liver Parenchyma: Comparison Between Xenon CT and Perfusion CT

被引:0
|
作者
Kazuhiko Hashimoto
Takamichi Murakami
Keizo Dono
Masatoshi Hori
Tonsok Kim
Masayuki Kudo
Shigeru Marubashi
Atsushi Miyamoto
Yutaka Takeda
Hiroaki Nagano
Koji Umeshita
Hironobu Nakamura
Morito Monden
机构
[1] Osaka University,Department of Surgery, Graduate School of Medicine
[2] Osaka University,Department of Radiology, Graduate School of Medicine
[3] Imaging Application Tech Center GE Yokogawa Medical Systems,undefined
来源
关键词
Hepatic tissue blood flow; Xenon CT; Perfusion CT; Hepatic arterial tissue blood flow; Portal venous tissue blood flow; Hepatic arterial fraction;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to compare measurements of hepatic tissue blood flow (TBF) calculated by xenon and perfusion CT. Seven patients with normal liver and eight with chronic liver disease underwent both xenon and perfusion CT. During xenon CT examinations, serial abdominal CT scans were obtained every minute before and during 4 min of nonradioactive 25% (v/v) xenon gas inhalation and 5 min of administration of oxygen-rich air. Hepatic arterial and portal venous TBF were measured separately with a special imaging system using the Kety-Schmidt expression based on the Fick principle (AZ-7000W; Anzai Medical Co.). The hepatic arterial fraction (HAF) was calculated as follows: [hepatic arterial TBF/(hepatic arterial TBF + portal venous TBF)]. During perfusion CT examinations, total hepatic TBF and HAF were also calculated from the enhanced CT cine image data on a workstation using a commercially available software package based on a deconvolution algorithm (CT Perfusion 3 GE Healthcare, USA). Total hepatic TBF measured by xenon and perfusion CT was 82.9±15 and 82.8±18 ml/min/100 g, respectively. The measured values by the two techniques showed a significant correlation (R2= 0.657, P < 0.05). HAF measured by xenon and perfusion CT was 26.6±11 and 21.8±13%, respectively. The measured values by the two techniques also showed a significant correlation (R2= 0.869, P < 0.05). We conclude that there was a good correlation between hepatic TBF quantified by xenon CT and perfusion CT.
引用
收藏
页码:943 / 949
页数:6
相关论文
共 50 条
  • [31] CEREBRAL BLOOD-FLOW - MEASUREMENT WITH XENON-ENHANCED DYNAMIC HELICAL CT
    NAMBU, K
    SUZUKI, R
    HIRAKAWA, K
    RADIOLOGY, 1995, 195 (01) : 53 - 57
  • [32] CT perfusion of the liver: Assessment of the pure portal blood flow studied with CT perfusion during superior mesenteric arterial portography
    Tanigawa, N
    Komemushi, A
    Kojima, H
    Kariya, S
    Sougawa, M
    Sawada, S
    RADIOLOGY, 2002, 225 : 486 - 486
  • [33] Xenon CT cerebral blood flow in acute stroke
    Gupta, R
    Jovin, TG
    Yonas, H
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2005, 15 (03) : 531 - +
  • [34] Quantitative assessment of regional cerebral blood flows by perfusion CT: A validation study in humans through simultaneous cerebral Xenon-CT
    Wintermark, M
    Maeder, PP
    Thiran, JP
    Schnyder, P
    Meuli, RA
    RADIOLOGY, 2000, 217 : 555 - 556
  • [35] Effect of choice of artery in the measurement of cerebral blood flow in stroke by CT perfusion
    Lee, T
    Lev, MH
    Eastwood, JD
    Provenzale, JM
    Azhari, T
    Herzau, MA
    RADIOLOGY, 2001, 221 : 481 - 481
  • [36] Hepatic blood flow measurements of liver grafts in lliving donor liver transplantation by means of Xenon CT
    Hashimoto, K
    Dono, K
    Sakon, M
    Kubota, M
    Kobayashi, S
    Goto, K
    Yamamoto, S
    Marubashi, S
    Kato, T
    Nagano, H
    Umeshita, K
    Nakamori, S
    Monden, M
    LIVER TRANSPLANTATION, 2003, 9 (06) : C12 - C12
  • [37] Quantitative cerebral blood flow calculation method using white matter lambda in xenon CT
    Sase, S
    Honda, M
    Kushida, T
    Seiki, Y
    Machida, K
    Shibata, L
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (03) : 471 - 478
  • [38] A newly developed Xenon CT imaging for separately measurement of the hepatic arterial and portal venous tissue blood flow: An animal study
    Hayashi, S
    Murakami, T
    Shimizu, J
    Takamura, M
    Dono, K
    Nakamura, H
    RADIOLOGY, 2001, 221 : 110 - 110
  • [39] THE AVM VASCULAR STEAL - CEREBRAL BLOOD-FLOW MEASUREMENT USING XENON ENHANCED CT
    ODONOHUE, JM
    ENZMANN, DR
    MARSHALL, WH
    HAAS, RA
    SILVERBERG, G
    FABRIKANT, JI
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1985, 6 (03) : 478 - 478
  • [40] Comparison of cerebral blood flow (CBF) data obtained by perfusion CT (PCT) with that obtained by xenon CT (XeCT) using 320-row CT and automated region of interest (ROI) determining software
    Takahashi, S.
    Tanizaki, Y.
    Kimura, H.
    Akaji, K.
    Kano, T.
    Suzuki, K.
    Takayama, Y.
    Kanzawa, T.
    Nakazawa, M.
    Mihara, B.
    CEREBROVASCULAR DISEASES, 2014, 37 : 494 - 494