Measurement of Specific Heat Capacity from 150 to 310 K by Thermal Radiation Calorimetry

被引:0
|
作者
S. Sawai
H. Tanaka
K. Morimoto
K. Hisano
机构
[1] National Defense Academy,Department of Mathematics and Physics
来源
关键词
effective emissivity; specific heat capacity; thermal radiation calorimetry;
D O I
暂无
中图分类号
学科分类号
摘要
A novel method for measurement of the specific heat capacity in the temperature range from 150 to 310 K is described. In order to achieve good temperature homogeneity in a disk-shaped specimen, a cylindrical heater was used in an apparatus based on thermal radiation calorimetry. A mixture of Bi2O3 and MgO powders was used for blackening the surfaces of the specimen, the heater, and the inside wall of the chamber. The specific heat capacities of Ni, fused quartz glass, and BaTiO3 ceramic were measured to test the performance of the calorimeter. Agreement to within 5% of the values published in the literature was obtained for these samples. Thermal hysteresis and anomalies associated with the first-order phase transition in BaTiO3 were detected in the present experiment.
引用
收藏
页码:721 / 731
页数:10
相关论文
共 50 条
  • [21] Heat Capacity Measurement by Flow Calorimetry: An Exact Analysis
    Hei, T. K.
    Raal, J. D.
    AICHE JOURNAL, 2009, 55 (01) : 206 - 216
  • [22] Thermal Radiation Calorimeter for Measuring the Specific Heat Capacity of Liquid Samples
    S. Sawai
    A. Uematsu
    K. Morimoto
    K. Hisano
    International Journal of Thermophysics, 2002, 23 : 1617 - 1629
  • [23] Thermal radiation calorimeter for measuring the specific heat capacity of liquid samples
    Sawai, S
    Uematsu, A
    Morimoto, K
    Hisano, K
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2002, 23 (06) : 1617 - 1629
  • [24] Measurement of specific heat capacity via fast scanning calorimetry-Accuracy and loss corrections
    Quick, C. R.
    Schawe, J. E. K.
    Uggowitzer, P. J.
    Pogatscher, S.
    THERMOCHIMICA ACTA, 2019, 677 : 12 - 20
  • [25] Interlaboratory precision and bias for thermal conductivity and specific heat capacity by modulated differential scanning calorimetry
    Blaine, R. L.
    Thermal Conductivity 26: Thermal Expansion 14, 2005, 26 : 309 - 318
  • [26] Thermal conductivity of uranium dioxide up to 2900 K from simultaneous measurement of the heat capacity and thermal diffusivity
    Ronchi, C
    Sheindlin, M
    Musella, M
    Hyland, GJ
    JOURNAL OF APPLIED PHYSICS, 1999, 85 (02) : 776 - 789
  • [28] Applications of AC calorimetry and differential phase calorimetry in the measurement of heat capacity and phase transitions
    Maesono, A
    Tye, RP
    HIGH TEMPERATURES-HIGH PRESSURES, 1998, 30 (06) : 695 - 700
  • [29] Measurement of heat capacity for borage seeds by differential scanning calorimetry
    Yang, W
    Sokhansanj, S
    Tabil, L
    Tang, J
    Yannacopoulos, S
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 1997, 21 (05) : 395 - 407
  • [30] Specific Heat Capacity at Constant Pressure of Ethanol by Flow Calorimetry
    Miyazawa, Taishi
    Kondo, Satoshi
    Suzuki, Takuya
    Sato, Haruki
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2012, 57 (06): : 1700 - 1707