Sustained inflation and incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation in a large porcine model of acute respiratory distress syndrome

被引:12
|
作者
Muellenbach R.M. [1 ]
Kredel M. [1 ]
Zollhoefer B. [1 ]
Wunder C. [1 ]
Roewer N. [1 ]
Brederlau J. [1 ]
机构
[1] Department of Anaesthesiology, University of Wuerzburg, 97080 Wuerzburg
关键词
Mean Arterial Pressure; Acute Respiratory Distress Syndrome; Central Venous Pressure; Acute Respiratory Distress Syndrome Patient; Recruitment Manoeuvre;
D O I
10.1186/1471-2253-6-8
中图分类号
学科分类号
摘要
Background: To compare the effect of a sustained inflation followed by an incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation on oxygenation and hemodynamics in a large porcine model of early acute respiratory distress syndrome. Methods: Severe lung injury (Ali) was induced in 18 healthy pigs (55.3 ± 3.9 kg, mean ± SD) by repeated saline lung lavage until PaO2 decreased to less than 60 mmHg. After a stabilisation period of 60 minutes, the animals were randomly assigned to two groups: Group I (Pressure controlled ventilation; PCV): FlO2 = 1.0, PEEP = 5 cmH2O, VT = 6 ml/kg, respiratory rate = 30/min, I:E = 1:1; group 2 (High-frequency oscillatory ventilation; HFOV): FlO2 = 1.0, Bias flow = 30 l/min, Amplitude = 60 cmH2O, Frequency = 6 Hz, I:E = 1:1. A sustained inflation (SI; 50 cmH2O for 60s) followed by an incremental mean airway pressure (mPaw) trial (steps of 3 cmH2O every 15 minutes) were performed in both groups until PaO2 no longer increased. This was regarded as full lung inflation. The mPaw was decreased by 3 cmH2O and the animals reached the end of the study protocol. Gas exchange and hemodynamic data were collected at each step. Results: The SI led to a significant improvement of the PaO2/ FiO2-Index (HFOV: 200 ± 100 vs. PCV: 58 ± 15 and TAli: 57 ± 12; p < 0.001) and PaCO2-reduction (HFOV: 42 ± 5 vs. PCV: 62 ± 13 and TAli: 55 ± 9; p <0.001) during HFOV compared to lung injury and PCV. Augmentation of mPaw improved gas exchange and pulmonary shunt fraction in both groups, but at a significant lower mPaw in the HFOV treated animals. Cardiac output was continuously deteriorating during the recruitment manoeuvre in both study groups (HFOV: TAli: 6.1 ± 1 vs. T75: 3.4 ± 0.4; PCV: TAli: 6.7 ± 2.4 vs. T75: 4 ± 0.5; p <0.001). Conclusion: A sustained inflation followed by an incremental mean airway pressure trial in HFOV improved oxygenation at a lower mPaw than during conventional lung protective ventilation. HFOV but not PCV resulted in normocapnia, suggesting that during HFOV there are alternatives to tidal ventilation to achieve CO2-elimination in an "open lung" approach. © 2006 Muellenbach et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 50 条
  • [41] The role of high frequency oscillatory ventilation in acute respiratory distress syndrome
    Gubran, Christopher
    Braganza-Menezes, Darryl
    [J]. THORAX, 2013, 68 (05) : 467 - 467
  • [42] RANDOMIZED TRIAL OF HIGH-FREQUENCY JET VENTILATION VERSUS CONVENTIONAL VENTILATION IN RESPIRATORY-DISTRESS SYNDROME
    CARLO, WA
    CHATBURN, RL
    MARTIN, RJ
    [J]. JOURNAL OF PEDIATRICS, 1987, 110 (02): : 275 - 282
  • [43] High frequency oscillatory ventilation in patients with acute respiratory distress syndrome
    Andersen, FA
    Guttormsen, AB
    Flaatten, HK
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 : S141 - S141
  • [44] Comparison of prone positioning and high-frequency oscillatory ventilation in patients with acute respiratory distress syndrome
    Papazian, L
    Gainnier, M
    Marin, V
    Donati, S
    Arnal, JM
    Demory, D
    Roch, A
    Forel, JM
    Bongrand, P
    Brégeon, F
    Sainty, JM
    [J]. CRITICAL CARE MEDICINE, 2005, 33 (10) : 2162 - 2171
  • [45] High-Frequency Oscillatory Ventilation for Cardiac Surgery Children With Severe Acute Respiratory Distress Syndrome
    Shengli Li
    Xu Wang
    Shoujun Li
    Jun Yan
    [J]. Pediatric Cardiology, 2013, 34 : 1382 - 1388
  • [46] High-Frequency Oscillatory Ventilation for Cardiac Surgery Children With Severe Acute Respiratory Distress Syndrome
    Li, Shengli
    Wang, Xu
    Li, Shoujun
    Yan, Jun
    [J]. PEDIATRIC CARDIOLOGY, 2013, 34 (06) : 1382 - 1388
  • [47] pH: an overlooked criterion for success in high-frequency oscillatory ventilation in acute respiratory distress syndrome?
    K Madhusudana
    K Black
    C Melville
    [J]. Critical Care, 11 (Suppl 2):
  • [48] HOT OFF THE BREATH High-frequency oscillatory ventilation and acute respiratory distress syndrome: at the crossroads?
    Wise, Matt P.
    Saayman, Anton G.
    Gillies, Michael A.
    [J]. THORAX, 2013, 68 (05) : 406 - 408
  • [49] CLINICAL USE OF HIGH-FREQUENCY OSCILLATORY VENTILATION FOR ACUTE RESPIRATORY DISTRESS SYNDROME IN PAEDIATRIC PATIENTS
    Yildizdas, Dincer
    Yapicioglu, Hacer
    Bayram, Ibrahim
    Yilmaz, H. Ievent
    Sertdemir, Yasar
    [J]. CRITICAL CARE MEDICINE, 2008, 36 (12) : A179 - A179
  • [50] High-frequency oscillatory ventilation in adults with traumatic brain injury and acute respiratory distress syndrome
    David, M
    Karmrodt, J
    Weiler, N
    Scholz, A
    Markstaller, K
    Eberle, B
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (02) : 209 - 214