Accuracy of static fully guided implant placement in the posterior area of partially edentulous jaws: a cohort prospective study

被引:0
|
作者
Jordi Gargallo-Albiol
María José Zilleruelo-Pozo
Ernest Lucas-Taulé
Jesús Muñoz-Peñalver
Daniel Paternostro-Betancourt
Federico Hernandez-Alfaro
机构
[1] Universitat Internacional de Catalunya,Department of Oral and Maxillofacial Surgery, C/JosepTrueta S/N
[2] University of Michigan School of Dentistry,Department of Periodontics and Oral Medicine
[3] Universitat Internacional de Catalunya,Department of Periodontics
[4] C/Josep Trueta S/N,undefined
来源
关键词
Accuracy; Computer-aided surgery; Computer-assisted; Three-dimensional imaging; Dental implants;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2783 / 2791
页数:8
相关论文
共 50 条
  • [31] Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study
    Ku, Jeong-Kui
    Lee, Junggon
    Lee, Hyo-Jung
    Yun, Pil-Young
    Kim, Young-Kyun
    BMC ORAL HEALTH, 2022, 22 (01)
  • [32] Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study
    Jeong-Kui Ku
    Junggon Lee
    Hyo-Jung Lee
    Pil-Young Yun
    Young-Kyun Kim
    BMC Oral Health, 22
  • [33] Does the fixture thread depth affect the accuracy of implant placement during fully guided immediate implant placement?: A human cadaver study
    Song, Young Woo
    Park, Jin-Young
    Jung, Ji-Young
    Kim, Joo-Nyeon
    Hu, Kyung-Seok
    Lee, Jung-Seok
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (02) : 116 - 126
  • [34] Accuracy of the Yakebot dental implant robotic system versus fully guided static computer-assisted implant surgery template in edentulous jaw implantation: A preliminary clinical study
    Wang, Wenxue
    Xu, Hao
    Mei, Dongmei
    Zhou, Chen
    Li, Xiaojing
    Han, Ze'yu
    Zhou, Xiaobin
    Li, Xin
    Zhao, Baodong
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 309 - 316
  • [35] Accuracy of Computer-Guided Flapless Implant Surgery in Fully Edentulous Arches and in Edentulous Arches With Fresh Extraction Sockets
    Albiero, Alberto M.
    Quartuccio, Luca
    Benato, Andrea
    Benato, Renato
    IMPLANT DENTISTRY, 2019, 28 (03) : 256 - 264
  • [36] The Influence of Surgical Experience and Bone Density on the Accuracy of Static Computer-Assisted Implant Surgery in Edentulous Jaws Using a Mucosa-Supported Surgical Template with a Half-Guided Implant Placement Protocol-A Randomized Clinical Study
    Kivovics, Marton
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    MATERIALS, 2020, 13 (24) : 1 - 12
  • [37] Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: An in vitro study
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (05) : 608 - 618
  • [38] Influence of the macrodesign of an implant and the sleeve system on the accuracy of template-guided implant placement: A prospective clinical study
    Schnutenhaus, Sigmar
    Edelmann, Cornelia
    Wetzel, Martin
    Luthardt, Ralph G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02): : 212 - 219
  • [39] The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis
    Putra, Ramadhan Hardani
    Yoda, Nobuhiro
    Astuti, Eha Renwi
    Sasaki, Keiichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 29 - 39
  • [40] A Prospective Study on Accuracy of Computer-Based Fully Guided Versus Pilot-Guided Implant Surgery
    Kim, Hyo Joon
    Kim, Hee Jin
    Moon, Seong Yong
    APPLIED SCIENCES-BASEL, 2020, 10 (06):