Sensitive aptamer-based fluorescence polarization assay for mercury(II) ions and cysteine using silver nanoparticles as a signal amplifier

被引:3
|
作者
Yixuan Jiang
Jianniao Tian
Kun Hu
Yanchun Zhao
Shulin Zhao
机构
[1] School of Chemistry and Pharmaceutical Science of Guangxi Normal University,Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China)
来源
Microchimica Acta | 2014年 / 181卷
关键词
Fluorescence polarization (FP); Silver nanoparticles; Mercury ions; Cysteine;
D O I
暂无
中图分类号
学科分类号
摘要
We report here a signal amplifying strategy to construct polarization aptamer probes for small molecules. The method is based on the use of silver nanoparticles acting as a fluorescence polarization signal amplifier. It was applied to the sensitive and selective detection of the two model analytes mercury (II) and cysteine. The aptamer probes were conjugated to CdTe-CdS quantum dots and are shown to work well for both analytes. The analytical range for Hg(II) is from 10 nM to 0.4 μM, and the limit of detection is 6.6 nM. The respective range for cysteine is from 20 nM to 0.7 μM, and the LOD is 11 nM.
引用
收藏
页码:1423 / 1430
页数:7
相关论文
共 50 条
  • [31] An aptamer-based colorimetric lead(II) assay based on the use of gold nanoparticles modified with dsDNA and exonuclease I
    Mahin Shahdordizadeh
    Rezvan Yazdian-Robati
    Najmeh Ansari
    Mohammad Ramezani
    Khalil Abnous
    Seyed Mohammad Taghdisi
    Microchimica Acta, 2018, 185
  • [32] An aptamer-based colorimetric lead(II) assay based on the use of gold nanoparticles modified with dsDNA and exonuclease I
    Shahdordizadeh, Mahin
    Yazdian-Robati, Rezvan
    Ansari, Najmeh
    Ramezani, Mohammad
    Abnous, Khalil
    Taghdisi, Seyed Mohammad
    MICROCHIMICA ACTA, 2018, 185 (02)
  • [33] Electrocatalytic assay of mercury(II) ions using a bifunctional oligonucleotide signal probe
    Zhang, Ziping
    Yin, Jungang
    Wu, Zhaoyang
    Yu, Ruqin
    ANALYTICA CHIMICA ACTA, 2013, 762 : 47 - 53
  • [34] Label-free aptamer-based colorimetric detection of mercury ions in aqueous media using unmodified gold nanoparticles as colorimetric probe
    Li Li
    Baoxin Li
    Yingying Qi
    Yan Jin
    Analytical and Bioanalytical Chemistry, 2009, 393 : 2051 - 2057
  • [35] Label-free aptamer-based colorimetric detection of mercury ions in aqueous media using unmodified gold nanoparticles as colorimetric probe
    Li, Li
    Li, Baoxin
    Qi, Yingying
    Jin, Yan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (08) : 2051 - 2057
  • [36] Chitosan-stabilized Silver Nanoparticles for Colorimetric Assay of Mercury (II) Ions in aqueous system
    Zarlaida, Fitri
    Adlim, M.
    Surbakti, M. Syukri
    Omar, Ahmad Fairuz
    7TH AIC-ICMR ON SCIENCES AND ENGINEERING 2017, 2018, 352
  • [37] Aptamer Structure Switch Fluorescence Anisotropy Assay for Small Molecules Using Streptavidin as an Effective Signal Amplifier Based on Proximity Effect
    Li, Yapiao
    Zhao, Qiang
    ANALYTICAL CHEMISTRY, 2019, 91 (11) : 7379 - 7384
  • [38] Aptamer-based detection of Salmonella enteritidis using double signal amplification by Klenow fragment and dual fluorescence
    Keyi Liu
    Xing Yan
    Biyao Mao
    Sheng Wang
    Le Deng
    Microchimica Acta, 2016, 183 : 643 - 649
  • [39] An aptamer-based colorimetric assay for chloramphenicol using a polymeric HRP-antibody conjugate for signal amplification
    Gao, Huiju
    Pan, Daodong
    Gan, Ning
    Cao, Jinxuan
    Sun, Yangying
    Wu, Zhen
    Zeng, Xiaoqun
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2551 - 2559
  • [40] Aptamer-based fluorescent solid-phase thrombin assay using a silver-coated glass substrate and signal amplification by glucose oxidase
    Yubin Li
    Liansheng Ling
    Microchimica Acta, 2015, 182 : 1849 - 1854