Sliding mode control for performance improvement of shunt active power filter

被引:0
|
作者
Ikram Ullah
Muhammad Ashraf
机构
[1] Capital University of Science and Technology (CUST),Department of Electrical Engineering
来源
SN Applied Sciences | 2019年 / 1卷
关键词
Harmonics mitigation; Shunt active power filter; Power quality improvement;
D O I
暂无
中图分类号
学科分类号
摘要
The increased use of non-linear loads results in more harmonics content in the source current. Shunt active power filters are used for correction of distorted source current by injecting a compensating current in parallel to the load current. The injected current will shape the supply current to a sinusoidal. In this paper an improved performance of shunt active power filter is achieved by using sliding mode controller for generation of gate pulses of voltage source inverter. The implemented control technique has been evaluated and compared with hysteresis current control. The performance parameters used for evaluating the shunt active power filter are total harmonic distortion, power factor and harmonics compensation ratio. The simulation results show excellent performance of active power filter in terms of harmonics mitigation and dynamic response. Experimental tests are also performed using NI DAQ card in Labview environment to validate the simulation results. Both the simulation and experimental results prove good performance of sliding mode control for accurate injection of reference current.
引用
收藏
相关论文
共 50 条
  • [41] Sliding mode control applied to a 3Φ shunt active power filter using compensation with instantaneous reactive power theory
    Cárdenas, V
    Vazquez, N
    Hernández, C
    [J]. PESC 98 RECORD - 29TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1 AND 2, 1998, : 236 - 241
  • [42] Fuzzy Logic Control of Shunt Active Power Filter for Power Quality Improvement
    Anjana, S.
    Maya, P.
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SOFT COMPUTING SYSTEMS, ICSCS 2015, VOL 1, 2016, 397 : 975 - 985
  • [44] PERFORMANCE IMPROVEMENT FOR A SINGLE-PHASE SHUNT ACTIVE POWER FILTER
    Teodorescu, Mihail
    Radoi, Constantin
    Stanciu, Dumitru
    Rosu, Stefan G.
    [J]. UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2013, 75 (04): : 109 - 120
  • [45] Performance improvement of shunt active power filter with dual parallel topology
    Asiminoaei, Lucian
    Lascu, Cristian
    Blaabjerg, Frede
    Boldea, Ion
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (01) : 247 - 259
  • [46] Improvement for The Closed-Loop Control of Shunt Active Power Filter
    Sun, Xiaofeng
    Li, Ningning
    Wang, Baocheng
    Li, Xin
    [J]. 2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1687 - 1692
  • [47] Design and Implementation of Sliding Mode and PI Controllers based Control for Three Phase Shunt Active Power Filter
    Benchouia, M. T.
    Ghadbane, I.
    Golea, A.
    Srairi, K.
    Benbouzid, M. H.
    [J]. TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 : 504 - 511
  • [48] Sliding-mode Control Based Three-phase Shunt Active Power Filter: Simulation and Experimentation
    Ghamri, A.
    Benchouia, M. T.
    Golea, A.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2012, 40 (04) : 383 - 398
  • [49] ANALYSIS AND SLIDING MODE CONTROL OF FOUR-WIRE THREE-LEG SHUNT ACTIVE POWER FILTER
    Hamoudi, Farid
    Amimeur, Hocine
    [J]. ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2015, 13 (05) : 430 - 441
  • [50] Adaptive Harmonic Compensation of Shunt Active Power Filter Using Sliding Mode Controller
    Fei, Juntao
    Zhang, Shenglei
    Jianzhou
    [J]. 2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2012), 2012,