Development and Validation of a Method for the Determination of Quinolones in Muscle and Eggs by Liquid Chromatography-Tandem Mass Spectrometry

被引:0
|
作者
Loredana Annunziata
Pierina Visciano
Arianna Stramenga
Maria Novella Colagrande
Guido Campana
Giampiero Scortichini
Giacomo Migliorati
Dario Compagnone
机构
[1] Istituto Zooprofilattico Sperimentale dell’Abruzzo e del Molise “G. Caporale”,Faculty of BioScience and Technology for Food, Agriculture and Environment
[2] University of Teramo,undefined
[3] Istituto Zooprofilattico Sperimentale dell’Umbria e delle Marche,undefined
来源
Food Analytical Methods | 2016年 / 9卷
关键词
Quinolones; Muscle; Eggs; Liquid chromatography-tandem mass spectrometry; Method validation;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, the development and validation of a multiresidue method for the detection of 11 quinolones (marbofloxacin, norfloxacin, ciprofloxacin, danofloxacin, lomefloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid, nalidixic acid, flumequine) in muscle and eggs were reported. The method involved an extraction with a methanol/metaphosphoric acid mixture and a clean up by Oasis hydrophilic-lipophilic balance (HLB) cartridge. The validation was performed according to the Commission Decision 2002/657/EC. Linearity, specificity, decision limit (CCα), detection capability (CCβ), recovery, precision (repeatability and within-laboratory reproducibility), and ruggedness were determined. Depending on the analytes, CCα and CCβ ranged from 113 to 234 μg/kg and from 126 to 282 μg/kg in muscle samples, whereas in eggs, these parameters were between 5.6 and 7.4 μg/kg and between 6.1 and 9.8 μg/kg, respectively. In both the examined matrices, the recovery values were always higher than 90 % and precision, calculated as relative standard deviation, was equal to or lower than 16 % for repeatability and 23 % for within-laboratory reproducibility. The described method can be considered adequate for the simultaneous determination and quantification of quinolones in the tested food matrices.
引用
下载
收藏
页码:2308 / 2320
页数:12
相关论文
共 50 条
  • [31] Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Ezetimibe in Human Plasma and Pharmaceutical Formulations
    P. R. Oliveira
    L. Brum Junior
    M. Fronza
    L. S. Bernardi
    S. M. K. Masiero
    S. L. Dalmora
    Chromatographia, 2006, 63 : 315 - 320
  • [32] Method development for the determination of 52 pesticides in tobacco by liquid chromatography-tandem mass spectrometry
    Mayer-Helm, Bernhard
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (51) : 8953 - 8959
  • [33] Validation of a chiral liquid chromatography-tandem mass spectrometry method for the determination of pantoprazole in dog plasma
    Chen, Meixia
    Xia, Yu
    Ma, Zhiyu
    Li, Liang
    Zhong, Dafang
    Chen, Xiaoyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 906 : 85 - 90
  • [34] High-performance liquid chromatography-tandem mass spectrometry for the determination of sulfonamides in eggs
    Tamosiunas, Vytautas
    Padarauskas, Audrius
    CHEMIJA, 2007, 18 (03): : 20 - 24
  • [35] Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Estimation of Rivaroxaban in Human Plasma
    Pathan, Mudassarahemadkhan
    Kshirsagar, Ajay
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (06) : 876 - 889
  • [36] Method Development and Validation of Ephedrine and Pseudoephedrine in Horse Urine by Liquid Chromatography-Tandem Mass Spectrometry
    Maurya, Ashok Kumar
    Sahu, Puran Lal
    Jethi, Sakshi
    Gosain, Himank
    Sahu, Kapendra
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2020, 54 (03) : S671 - S676
  • [37] Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of opiorphin in human saliva
    Brkljacic, Lidija
    Sabalic, Maja
    Salaric, Ivan
    Jeric, Ivanka
    Alajbeg, Ivan
    Nemet, Ina
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3920 - 3926
  • [38] Development and validation of a liquid chromatography-tandem mass spectrometry method for quantification of decitabine in rat plasma
    Xu, Haiyan
    Iv, Shaoqiong
    Qiao, Mingxi
    Fu, Yao
    Jiang, Xue
    Jin, Yi
    Li, Chibing
    Yuan, Bo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 81 - 85
  • [39] Bioanalytical Method Development and Validation of Selinexor in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Yaswanth, Murthaeti
    Sreekanth, M.
    Valli, Syed Sadaq
    Narayana, D. Venkata
    Sreedhar, V
    Venkataramana, Kanuma
    Pravallika, K. E.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2022, 12 (04): : 41 - 53
  • [40] Determination of dalcetrapib by liquid chromatography-tandem mass spectrometry
    Heinig, Katja
    Bucheli, Franz
    Kuhlmann, Olaf
    Zell, Manfred
    Paehler, Axel
    Zwanziger, Elke
    Gross, Guenter
    Tardio, Joseph
    Ishikawa, Tomohiro
    Yamashita, Tomoko
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 314 - 324