A Preliminary Comparison of Videofluoroscopy of Swallow and Pulse Oximetry in the Identification of Aspiration in Dysphagic Patients

被引:0
|
作者
Cameron Sellars
Catherine Dunnet
Roger Carter
机构
[1] Department of Speech & Language Therapy,
[2] Glasgow Royal Infirmary,undefined
[3] Glasgow,undefined
[4] UK,undefined
[5] Department of Respiratory Medicine,undefined
[6] Glasgow Royal Infirmary,undefined
[7] Glasgow,undefined
[8] UK,undefined
来源
Dysphagia | 1998年 / 13卷
关键词
Key words: Aspiration — Dysphagia — Hypoxemia — Pulse oximetry — Deglutition — Videofluoroscopy — Deglutition disorders.;
D O I
暂无
中图分类号
学科分类号
摘要
Pulse oximetry has recently received attention in the dysphagia literature because of its possible contribution to the management of neurogenic dysphagia. The present study was devised to examine whether pulse oximetry could be exploited to determine episodes of aspiration in patients with known dysphagia of neurologic origin. To this end, pulse oximetry was undertaken in six patients undergoing videofluoroscopic study of swallow. Normal controls also underwent pulse oximetry during feeding. The results indicate that there is no clear-cut relationship between changes in arterial oxygenation and aspiration. However, some support is found for the association between altered arterial oxygenation and oral feeding in dysphagic individuals. Further research in both normals and compromised individuals is needed.
引用
收藏
页码:82 / 86
页数:4
相关论文
共 35 条
  • [31] Diagnostic Yield Of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration For The Diagnosis Of Sarcoidosis: A Preliminary Comparison Of Sensitivity In Black Versus White Patients
    Rains, E. S.
    Calder, M.
    Meyer, T.
    Ciocca, V.
    Lande, L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [32] LITHIUM IODINE PULSE GENERATORS - COMPARISON OF THEORETICAL AND REAL LONGEVITY AND IDENTIFICATION OF PATIENTS AT HIGH-RISK OF PREMATURE FAILURE
    CAPPELLETTI, F
    ZANCHETTA, M
    MORLINO, T
    ALLEGRI, P
    CARROZZA, A
    MATURI, P
    ROSSI, M
    TREVISAN, G
    MAIOLINO, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (03): : A84 - A84
  • [33] Comparison of forehead Max-Fast pulse oximetry sensor with finger sensor at high positive end-expiratory pressure in adult patients with acute respiratory distress syndrome
    Hodgson, C. L.
    Tuxen, D. V.
    Holland, A. E.
    Keating, J. L.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (06) : 953 - 960
  • [34] Comparison of non-invasive measurement of caroid - Femoral pulse wave velocity and invasive maesurement of aortic pulse wave velocity and their accuracy in identification of patients with coronary artery disease.
    Podolec, Piotr
    Kopec, Grzegorz
    Podolec, Jakub
    Wilkolek, Piotr
    Krochin, Marek
    Rubis, Pawel
    Kaznica, Magdalena
    Pieculewicz, Monika
    Cwynar, Marcin
    Grodzicki, Tomasz
    Zmudka, Krzysztof
    Tracz, Wieslawa
    JOURNAL OF HYPERTENSION, 2006, 24 : 90 - 90
  • [35] Evaluation of point-of-care haemoglobin measuring devices: a comparison of Radical-7 pulse co-oximetry, Hemocue and laboratory measurements in obstetric patients (vol 68, pg 40, 2013)
    Skelton, V. A.
    Wijayasinghe, N.
    Sharafudeen, S.
    Sange, A.
    Parry, N. S.
    Junghans, C.
    ANAESTHESIA, 2013, 68 (05) : 547 - 548