A New and Simple Method for Distinguishing Complete from Incomplete Block Through the Cavotricuspid Isthmus

被引:0
|
作者
Gabriel Laurent
Alexandra Bourcier
Géraldine Bertaux
Stéphane Fromentin
Michel Fraison
Stéphanie Gonzalez
François Saint Pierre
Jean Eric Wolf
机构
[1] University Hospital Dijon,Department of Cardiology
[2] Hôpital Bocage,Département de Cardiologie
关键词
atrial flutter; catheter ablation; pacing manoeuvre;
D O I
暂无
中图分类号
学科分类号
摘要
Background: A complete line of block (CLOB) in the cavotricuspid isthmus (CTI) is the endpoint of typical atrial flutter ablation. Before CTI block is obtained, a progressive CTI conduction delay due to an incomplete line of block (InLOB) can be difficult to distinguish from CLOB. The purpose of this study was to assess a new simple approach based on the changes in atrio-ventricular (AV) conduction delays during septal and lateral right atrial pacing, to distinguish a CLOB from an InLOB during typical atrial flutter (AFL) ablation.
引用
收藏
页码:175 / 182
页数:7
相关论文
共 50 条
  • [31] A new method for vertical parallelisation of TAN learning based on balanced incomplete block designs
    Madsen, Anders L.
    Jensen, Frank
    Salmerón, Antonio
    Karlsen, Martin
    Langseth, Helge
    Nielsen, Thomas D.
    1600, Springer Verlag (8754): : 302 - 317
  • [32] A NEW METHOD OF ESTIMATING TREATMENT EFFECTS OR TREATMENT DIFFERENCES IN BALANCED INCOMPLETE BLOCK DESIGNS
    LEVY, PS
    ANNALS OF MATHEMATICAL STATISTICS, 1965, 36 (04): : 1325 - &
  • [33] A New Method for Vertical Parallelisation of TAN Learning Based on Balanced Incomplete Block Designs
    Madsen, Anders L.
    Jensen, Frank
    Salmeron, Antonio
    Karlsen, Martin
    Langseth, Helge
    Nielsen, Thomas D.
    PROBABILISTIC GRAPHICAL MODELS, 2014, 8754 : 302 - 317
  • [34] New simple capacity estimation method for multiuser block diagonalization transmission
    Kudo, Riichi
    Takatori, Yasushi
    Ohta, Atsushi
    Nishimori, Kentaro
    Kubota, Shuji
    2007 IEEE 65TH VEHICULAR TECHNOLOGY CONFERENCE, VOLS 1-6, 2007, : 1836 - 1840
  • [35] Simple method of using soda for distinguishing Killian–Jamieson diverticulum from a thyroid nodule
    Tae Hyun Kim
    Soonho Kim
    KS Chang
    Endocrine, 2015, 48 : 351 - 352
  • [36] A SIMPLE AND RAPID METHOD FOR DISTINGUISHING OPIUM OF MEXICAN ORIGIN FROM OTHER TYPES OF OPIUM
    GRLIC, L
    JOURNAL OF CRIMINAL LAW & CRIMINOLOGY, 1961, 52 (02): : 229 - 231
  • [38] A Simple, Rapid, and Practical Method for Distinguishing Lonicerae Japonicae Flos from Lonicerae Flos
    Zhang, Fang
    Shi, Pengliang
    Liu, Hongyan
    Zhang, Yongqing
    Yu, Xiao
    Li, Jing
    Pu, Gaobin
    MOLECULES, 2019, 24 (19):
  • [39] Positional pacing to discriminate transverse crista terminalis conduction from incomplete clockwise isthmus block during typical atrial flutter ablation.
    Anselme, F
    Cribier, A
    Saoudi, N
    CIRCULATION, 2000, 102 (18) : 621 - 621
  • [40] SIMPLE METHOD FOR COMPLETE PROCESSING OF DATA FROM LIQUID SCINTILLATION COUNTERS
    BARBER, HE
    BOURNE, GR
    BUCKLEY, GA
    JOURNAL OF PHYSIOLOGY-LONDON, 1971, 219 (02): : P4 - &