Bismuth fire assay preconcentration and empirical coefficient LA-ICP-MS for the determination of ultra-trace Pt and Pd in geochemical samples

被引:0
|
作者
Wenshan Ni
Xiangju Mao
Mingxing Yao
Xiaorui Guo
Qiliang Sun
Xiaofei Gao
Hongli Zhang
机构
[1] Zhengzhou Institute of Multipurpose Utilization of Mineral Resources,
[2] CAGS,undefined
[3] China National Engineering Research Center for Utilization of Industrial Minerals,undefined
[4] Key Laboratory of Evaluation and Multipurpose Utilization of Polymetallic Ores Ministry of Natural Resources,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In this work, a novel method of solid sample pretreatment technique of bismuth fire assay (Bi-FA) combined with solid sample determination by laser ablation ICP-MS (LA-ICP-MS) was reported for the determination of ultra-trace Pt and Pd in geochemical samples. Bismuth oxide (Bi2O3) was used as fire assay collector to directly enrich Pt and Pd from solid samples, and Ag protection cupellation was employed to generate Ag granules. After cleaning, weighing and annealing, the Ag granules were compressed into thin slices and determined by LA-ICP-MS for 195Pt, 105Pd and 109Ag (109Ag was selected as the internal standard isotope). Bi2O3 provided exceptionally low blanks compared to nickel oxide and lead oxide commonly employed in fire assay procedures, and could be applied directly without purification. Different from traditional empirical coefficient method, the Chinese Certified Reference Materials (CRMs) for Pt and Pd were treated by the same procedure to obtain completely matrix matched Ag slices. And then modified empirical coefficient method and internal standard calibration strategy was used to reduce the instability of LA-ICP-MS, and random multipoint laser ablation was employed to further reduce analytical variation resulting from heterogeneity of Pt and Pd in the Ag slice. Under optimal conditions, excellent calibration curves for Pt and Pd were obtained (0.407–2958 μg g−1 and 0.407–2636 μg g−1, respectively), with correlation coefficients exceeding 0.9996. The method detection limits for Pt and Pd were 0.074 and 0.037 ng g−1, respectively. The established method was applied successfully to analysis of real geochemical samples, with determined values in good agreement with the results of traditional Pb-FA graphite furnace atomic absorption spectrometry (GF-AAS), and spiked recoveries between 87.8 and 125.0%.
引用
收藏
相关论文
共 38 条
  • [21] Application of laser ablation inductively coupled mass spectrometry (LA-ICP-MS) for the determination of major, minor, and trace elements in bark samples
    Narewski, U
    Werner, G
    Schulz, H
    Vogt, C
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (02): : 167 - 170
  • [22] Ferrofluid-Based Preconcentration and Ultra-Trace Determination of Pt, Pd, Au, and Ag in Complex Matrices Using Inductively Coupled Plasma Mass Spectrometry
    Gotame, Yam Nath
    Gandolfi, Vivien
    Beauchemin, Diane
    ATOMIC SPECTROSCOPY, 2022, 43 (06) : 443 - 449
  • [23] Flow injection on-line preconcentration coupled with hydride generation atomic fluorescence Spectrometry for ultra-trace amounts of bismuth determination in biological and environmental water samples
    Wu, Hong
    Du, Baixiang
    Fang, Chao
    ANALYTICAL LETTERS, 2007, 40 (14) : 2772 - 2782
  • [24] Bismuth-Remaining Cupellation Fire Assay Preconcentration Combined with Inductively Coupled Plasma Mass Spectrometry for the Simultaneous Determination of Ultratrace Au, Pt, Pd, Ru, Rh, and Ir in Geologic Samples
    Ni, Wenshan
    Mao, Xiangju
    Yao, Mingxing
    Sun, Qiliang
    Guo, Xiaorui
    Zhang, Hongli
    Liu, Lu
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 2021
  • [25] A high-performance method for direct determination of ultra-trace REEs in geological samples by ICP-MS using a designed heating-condensing system
    Yu, Jiaxin
    Zhao, He
    He, Tao
    Luo, Tao
    Zhang, Wen
    Zong, Keqing
    Lin, Jie
    Liu, Yongsheng
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (04) : 723 - 732
  • [26] Semiautomatic method for the ultra-trace arsenic speciation in environmental and biological samples via magnetic solid phase extraction prior to HPLC-ICP-MS determination
    Montoro-Leal, P.
    Garcia-Mesa, J. C.
    Morales-Benitez, I
    Garcia de Torres, A.
    Vereda Alonso, E.
    TALANTA, 2021, 235 (235)
  • [27] Rapid Determination of Trace and Ultra Trace Level Elements in Diverse Silicate Rocks in Pressed Powder Pellet Targets by LA-ICP-MS using a Matrix-Independent Protocol
    Mukherjee, Pulok K.
    Khanna, Param P.
    Saini, Naresh K.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 363 - 379
  • [28] Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation
    Huang, Zhaoya
    Ni, Youyi
    Wang, Hai
    Zheng, Jian
    Yamazaki, Shinnosuke
    Sakaguchi, Aya
    Long, Xinggui
    Uchida, Shigeo
    MICROCHEMICAL JOURNAL, 2019, 148 : 597 - 604
  • [29] Determination of Ultra- Trace Au, Ag, As, Pt and Re Mass Fractions in Volcanic Glasses and Rock Powders by LA- ICP- MS
    Belgrano, Thomas M.
    Milton, James A.
    Teagle, Damon A. H.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2022, 46 (04) : 621 - 644
  • [30] Determination of ultra-trace Pu isotopes in large-volume seawater samples from the South Pacific Ocean using sector field ICP-MS combined with extraction chromatography
    Gu, Xiang
    Yang, Bo
    Yang, Guosheng
    Yamada, Masatoshi
    Wu, Fengchang
    Zheng, Jian
    MICROCHEMICAL JOURNAL, 2025, 208