A Concentric Tube Robot System for Rigid Bronchoscopy: A Feasibility Study on Central Airway Obstruction Removal

被引:0
|
作者
Joshua B. Gafford
Scott Webster
Neal Dillon
Evan Blum
Richard Hendrick
Fabien Maldonado
Erin A. Gillaspie
Otis B. Rickman
S. Duke Herrell
Robert J. Webster
机构
[1] Vanderbilt University,Mechanical Engineering Department
[2] Virtuoso Surgical,undefined
[3] Inc.,undefined
[4] Vanderbilt University Medical Center,undefined
[5] Vanderbilt Institute for Surgery and Engineering (VISE),undefined
来源
关键词
Central Airway Obstruction; Bronchoscopy; Robotics;
D O I
暂无
中图分类号
学科分类号
摘要
New robotic systems have recently emerged to assist with peripheral lung access, but a robotic system for rigid bronchoscopy has yet to be developed. We describe a new robotic system that can deliver thin robotic manipulators through the ports of standard rigid bronchoscopes. The manipulators bend and elongate to provide maneuverability of surgical tools at the endoscope tip, without endoscope motion. We describe an initial feasibility study on the use of this system to bronchoscopically treat a central airway obstruction (CAO). CAO is prevalent and can be life-threatening in patients with large tumors, and conventional rigid bronchoscopic treatments place patients at risk of complications including broken teeth, neck trauma and damage to oropharyngeal structures due to significant forces induced by bronchoscope tilting and manipulation. In this study, we used an ex vivo ovine airway model to demonstrate the ability of a physician using the robotic system to efficiently remove tissue and restore the airway. Pre- and post-operative CT scans showed that the robot was able to reduce the degree of airway obstruction stenosis from 75 to 14% on average for five CAO resections performed in an ex vivo animal model. Using cadaver experiments, we demonstrated the potential of the robotic system to substantially reduce the intraoperative forces applied to the patient’s head and neck (from 80.6 to 4.1 N). These preliminary results illustrate that CAO removal is feasible with our new rigid bronchoscopy robot system, and that this approach has the potential to reduce forces applied to the patient due to bronchoscope angulation, and thereby reduce the risk of complications encountered during CAO surgery.
引用
收藏
页码:181 / 191
页数:10
相关论文
共 50 条
  • [21] Usefulness of Emergent Intervention Under Rigid Bronchoscopy for Central Airway Obstruction Due to Undiagnosed and Untreated Neoplastic Tumor
    Takahama, Makoto
    KImura, Michitaka
    Nakajima, Ryu
    Yamamoto, Ryoji
    CHEST, 2016, 150 (04) : 36A - 36A
  • [22] Rigid Bronchoscopy for Malignant Central Airway Obstruction from Small Cell Lung Cancer Complicated by SVC Syndrome
    Jung, Bockhyun
    Murgu, Septimiu
    Colt, Henri
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 17 (01) : 53 - 57
  • [23] The role of interventional bronchoscopy in the management of malignant central airway obstruction
    Tabrizi, Nika Samadzadeh
    Stout, Perry A.
    Fabian, Tyler
    Fabian, Thomas
    RESPIRATORY MEDICINE CASE REPORTS, 2024, 47
  • [24] Safety and effectiveness of microdebrider bronchoscopy for the management of central airway obstruction
    Casal, Roberto F.
    Iribarren, Juan
    Eapen, George
    Ost, David
    Morice, Rodolfo
    Lan, Charlie
    Cornwell, Lorraine
    Almeida, Francisco A.
    Grosu, Horiana
    Jimenez, Carlos A.
    RESPIROLOGY, 2013, 18 (06) : 1011 - 1015
  • [25] Quantifying Central Airway Obstruction during Therapeutic Bronchoscopy Comment
    Debiane, Labib Gilles
    Ong, Philip
    Eapen, George A.
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2017, 14 (05) : 801 - 802
  • [26] Therapeutic Bronchoscopy in Multimodal Therapy for the Management of Central Airway Obstruction
    Fernandez-Trujillo, L.
    Morales, E.
    Lores, J.
    Aguirre, M.
    Castro, A.
    Sua, L.
    JOURNAL OF THORACIC ONCOLOGY, 2019, 14 (10) : S986 - S986
  • [27] Correlation of Bronchoscopy and CT in Characterizing Malignant Central Airway Obstruction
    Kalvapudi, Sukumar
    Zubair, Hafiz M.
    Kunadharaju, Rajesh
    Bhura, Sajeer
    Mengiste, Hiwot
    Saeed, Musa
    Saradna, Arjun
    Grover, Harshwant
    Shafirstein, Gal
    Yendamuri, Sai
    Ivanick, Nathaniel M.
    CANCERS, 2024, 16 (07)
  • [28] A MRI-Guided Concentric Tube Continuum Robot with Piezoelectric Actuation: A Feasibility Study
    Su, Hao
    Cardona, Diana C.
    Shang, Weijian
    Camilo, Alexander
    Cole, Gregory A.
    Rucker, D. Caleb
    Webster, Robert J., III
    Fischer, Gregory S.
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 1939 - 1945
  • [29] Rigid bronchoscopic intervention for malignant central airway obstruction
    Jeong, Byeong-Ho
    Kim, Hojoong
    PRECISION AND FUTURE MEDICINE, 2023, 7 (03): : 95 - 106
  • [30] The role of fiberoptic and rigid bronchoscopy in the diagnosis of malignant central airway pathologies
    Akyuez, Merve Sari
    Ozdemir, Cengiz
    Soekuecue, Sinem Nedime
    Atasever, Furkan
    Onur, Seda Tural
    Satici, Celal
    EURASIAN JOURNAL OF PULMONOLOGY, 2025, 27 (01) : 18 - 26