Quantitative analysis for sweat-absorbing times of paper-based microfluidic chips

被引:0
|
作者
Heyue Huang
Chuanpei Xu
Peng Long
Yanzhang Chen
Xijun Huang
Zheng Liu
Hong Yang
机构
[1] Guilin University of Electronic Technology,School of Electronic Engineering and Automation
[2] Guilin University of Aerospace Technology,School of Electronic Information and Automation
[3] Guangxi Key Laboratory of Automatic Detecting Technology and Instruments,School of Energy Science and Engineering
[4] Central South University,School of Energy and Building Environment
[5] Guilin University of Aerospace Technology,undefined
来源
关键词
The structure of paper-based microfluidic chips; Sweat-absorbing time; Richards’ equation; H value; Finite element analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Structures of paper-based microfluidic chips affect the sweat-absorbing time when they are used for sweat analysis. For the first time, we use COMSOL to establish two types of paper-based chip sweat-absorbing models that can quantitatively analyze this phenomenon. The standard model contains 1089 sweat glands, and the simplified model simplifies it according to the idea of finite element division, including 81 sweat glands. Sweat flows in from the bottom of the paper-based chip and out from the electrode contact surface (the upper surface of the central cylinder of the paper-based chip). Both models contain six paper-based chip structures, use Richards’ equation as the governing equation, set the outflow velocity to 0, and set the sweating rate of a sweat gland at 0.6 μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu$$\end{document}L/min. In the standard model, it takes only 46 s for the paper-based structure with the fastest sweat-absorbing speed to completely saturate the electrode contact surface with sweat (meaning the sweat-absorbing time is 46 s), which is 13.06%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\%$$\end{document} shorter than that of the slowest structure. In the simplified model, the top 3 structures of sweat-absorbing speed are consistent with the standard model. The simulation results show that the sweat-absorbing time is positively correlated with the H value of the bottom surface of the paper-based structure (defined as the area of the bottom surface /the area of sweat glands covered by the bottom surface), which can be proved by analytical and experimental methods. The analytical method proves that this conclusion can be generalized to other sweating rate conditions.
引用
收藏
相关论文
共 50 条
  • [41] Watermarking for Paper-Based Digital Microfluidic Biochips
    Li, Jian-De
    Wang, Sying-Jyan
    Li, Katherine Shu-Min
    Ho, Tsung-Yi
    [J]. Proceedings - 2020 IEEE International Test Conference in Asia, ITC-Asia 2020, 2020, : 148 - 153
  • [42] Paper-Based Microfluidic Devices by Plasma Treatment
    Li, Xu
    Tian, Junfei
    Nguyen, Thanh
    Shen, Wei
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (23) : 9131 - 9134
  • [43] Colorimetric Detection of Alkaline Phosphatase on Microfluidic Paper-based Analysis Devices
    Chen Xi
    Chen Jin
    Zhang Hui-Yan
    Wang Fu-Bing
    Wang Fang-Fang
    Ji Xing-Hu
    He Zhi-Ke
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (04) : 591 - 596
  • [44] Paper-based Microfluidic Device for Bisphenol A Based Chemical Reaction and Image Analysis
    Park, Hyung-Geun
    Kim, Ja-Young
    Yeo, Min-Kyeong
    [J]. BIOCHIP JOURNAL, 2016, 10 (01) : 25 - 33
  • [45] Paper-based microfluidic aptasensor for food safety
    Weng, Xuan
    Neethirajan, Suresh
    [J]. JOURNAL OF FOOD SAFETY, 2018, 38 (01)
  • [46] Paper-based Cell Culture Microfluidic System
    Tao, Fang Fang
    Xiao, Xia
    Lei, Kin Fong
    Lee, I-Chi
    [J]. BIOCHIP JOURNAL, 2015, 9 (02) : 97 - 104
  • [47] Paper-based microfluidic device for bisphenol A based chemical reaction and image analysis
    Hyung-Geun Park
    Ja-Young Kim
    Min-Kyeong Yeo
    [J]. BioChip Journal, 2016, 10 : 25 - 33
  • [48] Isotachophoretic Preconcenetration on Paper-Based Microfluidic Devices
    Moghadam, Babak Y.
    Connelly, Kelly T.
    Posner, Jonathan D.
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (12) : 5829 - 5837
  • [49] Advances on microfluidic paper-based electroanalytical devices
    Holman, Joseph Benjamin
    Shi, Zhengdi
    Fadahunsi, Adeola A.
    Li, Chengpan
    Ding, Weiping
    [J]. BIOTECHNOLOGY ADVANCES, 2023, 63
  • [50] Paper-based microfluidic devices by asymmetric calendaring
    Oyola-Reynoso, S.
    Frankiewicz, C.
    Chang, B.
    Chen, J.
    Bloch, J. -F.
    Thuo, M. M.
    [J]. BIOMICROFLUIDICS, 2017, 11 (01)