Analysis of whole blood samples with low gas flow inductively coupled plasma-optical emission spectrometry

被引:0
|
作者
Sascha Nowak
Jens Künnemeyer
Lydia Terborg
Stefan Trümpler
Andreas Günsel
Gerhard A. Wiesmüller
Uwe Karst
Wolfgang Buscher
机构
[1] University of Münster,Institute of Inorganic and Analytical Chemistry
[2] Environmental Specimen Bank for Human Tissues,undefined
来源
关键词
Inductively coupled plasma (ICP); Static high-sensitivity inductively coupled plasma (SHIP); Contrast agents; Thimerosal; Body fluids;
D O I
暂无
中图分类号
学科分类号
摘要
Low gas flow ICP-OES with a total argon consumption below 0.7 L/min is introduced for the analysis of trace elements in blood samples to investigate the influence of samples containing an organic solvent in a demanding matrix on the performance of this plasma for the first time. Therefore, gadolinium was determined in human plasma samples and mercury in red blood cells, human plasma, and precipitated plasma protein fraction. Limits of detection (LOD) were determined to be in the low microgram per liter range for the analytes and the accuracy of the method was assessed by comparison with a conventional Fassel-type torch-based ICP-OES. It was proven that the low gas flow ICP-OES leads to comparable results with the instrument based on the Fassel-type torch.
引用
收藏
页码:1023 / 1026
页数:3
相关论文
共 50 条
  • [21] Analysis of platinum concentrate by means of slurry nebulisation and inductively coupled plasma-optical emission spectrometry
    Schwarzer, Sieg
    Marjanovic, Ljiljana
    McCrindle, Robert I.
    Bratt, Ian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (09) : 978 - 981
  • [22] ENVIRONMENTAL SAMPLES ANALYSIS BY ATOMIC ABSORPTION SPECTROMETRY (AAS) AND INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROSCOPY (ICP-AES)
    Popescu, I. V.
    Stihi, C.
    Cimpoca, Gh V.
    Dima, G.
    Vlaicu, Gh
    Gheboianu, A.
    Bancuta, I.
    Ghisa, V.
    State, G.
    ROMANIAN JOURNAL OF PHYSICS, 2009, 54 (7-8): : 741 - 746
  • [23] Analysis of doped luminescent lanthanide fluoride nanoparticles by low gas flow inductively coupled plasma optical emission spectrometry
    Engelhard, Carsten
    Vielhaber, Torsten
    Scheffer, Andy
    Brocksieper, Mareike
    Buscher, Wolfgang
    Karst, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (03) : 407 - 411
  • [24] Plasma diagnostic on a low-flow plasma for inductively coupled plasma optical emission spectrometry
    Engelhard, Carsten
    Chan, George C. -Y.
    Gamez, Gerardo
    Buscher, Wolfgang
    Hieftje, Gary M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (06) : 619 - 629
  • [25] An environmental focus using inductively coupled plasma-optical emission spectrometry and ion chromatography
    Salido, A
    Atterholt, C
    Bacon, JR
    Butcher, DJ
    JOURNAL OF CHEMICAL EDUCATION, 2003, 80 (01) : 22 - 23
  • [26] The Role of Inductively Coupled Plasma-Optical Emission Spectrometry in Determining the Fineness of Precious Metals
    Manchanda, Dippal
    PLATINUM METALS REVIEW, 2011, 55 (04) : 281 - 283
  • [27] Nutritional element analysis in infant formulas by direct dispersion and inductively coupled plasma-optical emission spectrometry
    Hua, KM
    Kay, M
    Indyk, HE
    FOOD CHEMISTRY, 2000, 68 (04) : 463 - 470
  • [28] Determination of metallic elements in carbon nanotubes by inductively coupled plasma-optical emission spectrometry
    Ishikuro, M
    Sato, Y
    Tohji, K
    Wagatsuma, K
    BUNSEKI KAGAKU, 2006, 55 (02) : 117 - 120
  • [29] Elemental Analysis of Sea, Rock, and Bamboo Salts by Inductively Coupled Plasma-Optical Emission and Mass Spectrometry
    Hwang, In Min
    Yang, Ji-Su
    Kim, Sung Hyun
    Jamila, Nargis
    Khan, Naeem
    Kim, Kyong Su
    Seo, Hye-Young
    ANALYTICAL LETTERS, 2016, 49 (17) : 2807 - 2821
  • [30] Application of mathematical procedures to background correction and multivariate analysis in inductively coupled plasma-optical emission spectrometry
    Delft Univ of Technology, Delft, Netherlands
    Spectrochim Acta Part B At Spectrosc, 5 (639-669):