Evaluation of the performance of demand control ventilation system for school buildings located in the hot climate of Saudi Arabia

被引:0
|
作者
Alaa Alaidroos
Ayad Almaimani
Moncef Krarti
Ammar Dahlan
Rahif Maddah
机构
[1] King Abdulaziz University,Architectural Engineering Department
[2] King Abdulaziz University,Faculty of Architecture and Planning
[3] University of Colorado Boulder,Building Systems Program
来源
Building Simulation | 2022年 / 15卷
关键词
mechanical ventilation; demand control ventilation (DCV); indoor air quality (IAQ); CO; concentration; energy efficiency; school buildings;
D O I
暂无
中图分类号
学科分类号
摘要
The advantages of the demand control ventilation system (DCV) have been widely discussed in previous research studies. However, the literature has not addressed the benefits of DCV on controlling indoor CO2 concentration and minimizing cooling energy consumption for school buildings located in extremely hot climates. Therefore, this paper contributes to the development of DCV and mechanical ventilation systems through a comprehensive evaluation of these systems to maintain acceptable indoor air quality (IAQ) while minimizing cooling energy demands for school buildings located in the harsh hot climate of Saudi Arabia. The evaluation is based on a calibrated whole-building energy model and validated IAQ predictions using field data obtained from a school case study in Jeddah. The results of this research study confirm that hourly and sub-hourly monitoring of indoor CO2 concentration is required to ensure optimal design and operation of the ventilation systems in schools. In addition, the analyses indicate that a 13% increase in cooling energy end-use can result for any additional 0.1 students/m2 density increase in the classrooms. However, the energy penalties related to ventilation needs can be reduced by up to 25% using DCV instead of conventional mechanical ventilation systems for school buildings located in Saudi Arabia’s hot climate.
引用
收藏
页码:1067 / 1082
页数:15
相关论文
共 50 条
  • [41] Performance Analysis of Novel Thermal Storage Integrated Heat Pump System in a Residential Building at the Hot Climate for Demand Flexibility
    Shi, Liang
    Liu, Xiaobing
    Qu, Ming
    Shen, Bo
    [J]. ASHRAE TRANSACTIONS 2021, VOL 128, PT 1, 2022, 128 : 513 - 521
  • [42] Field measurements of post-operation evaluation of daylighting and thermal comfort in hot and arid climates: A pilot study of three educational buildings on the Najran University campus in Saudi Arabia
    Elbellahy, Shukri
    Alotaibi, Badr Saad
    Abuhussain, Mohammed Awad
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [43] Evaluation of performance of energy efficient hybrid ventilation system and analysis of occupants' behavior to control windows
    Cho, Haein
    Cabrera, Daniel
    Sardy, Sylvain
    Kilchherr, Romain
    Yilmaz, Selin
    Patel, Martin K.
    [J]. BUILDING AND ENVIRONMENT, 2021, 188
  • [44] Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control
    Yang, J.
    Sekhar, S. C.
    Cheong, K. W. D.
    Raphael, B.
    [J]. INDOOR AIR, 2015, 25 (02) : 176 - 187
  • [45] The Effects of Orientation, Window Size, and Lighting Control to Climate-Based Daylight Performance and Lighting Energy Demand on Buildings in Tropical Area
    Fela, Randy Frans
    Utami, Sentagi Sesotya
    Mangkuto, Rizki Armanto
    Suroso, Dwi Joko
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1075 - 1082
  • [46] Occupancy measurement in commercial office buildings for demand-driven control applications-A survey and detection system evaluation
    Labeodan, Timilehin
    Zeiler, Wim
    Boxem, Gert
    Zhao, Yang
    [J]. ENERGY AND BUILDINGS, 2015, 93 : 303 - 314
  • [47] A Module-Based Active Noise Control System for Ventilation Systems, Part II: Performance Evaluation
    Larsson, Martin
    Johansson, Sven
    Claesson, Ingvar
    Hakansson, Lars
    [J]. INTERNATIONAL JOURNAL OF ACOUSTICS AND VIBRATION, 2009, 14 (04): : 196 - 206
  • [48] Performance evaluation of CO2-based ventilation control to reduce CO2 concentration and condensation risk in residential buildings
    Shin, Mi-Su
    Rhee, Kyu-Nam
    Lee, Eun-Tack
    Jung, Gun-Joo
    [J]. BUILDING AND ENVIRONMENT, 2018, 142 : 451 - 463
  • [49] Energy Performance Evaluation of a Desiccant Air Handling System to Maximize Solar Thermal Energy Use in a Hot and Humid Climate
    Ukai, Makiko
    Okumiya, Masaya
    Tanaka, Hideki
    [J]. SUSTAINABILITY, 2020, 12 (05)
  • [50] Evaluation of energy efficient design strategies for different climatic zones: Comparison of thermal performance of buildings in temperate-humid and hot-dry climate
    Yilmaz, Z.
    [J]. ENERGY AND BUILDINGS, 2007, 39 (03) : 306 - 316