Utility of a High-Resolution 3D MRI Sequence (3D-SPACE) for Evaluation of Congenital Heart Disease

被引:0
|
作者
Ashkan A. Malayeri
Philip J. Spevak
Stefan L. Zimmerman
机构
[1] The Johns Hopkins Hospital,The Russell H. Morgan Department of Radiology and Radiological Science
[2] National Institutes of Health,undefined
来源
Pediatric Cardiology | 2015年 / 36卷
关键词
Congenital; Cardiac; MRI; SPACE; High-resolution imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to evaluate the role of a high-resolution 3D dark-blood turbo spin echo sequence with variable flip angles (3D-SPACE) in evaluation of congenital heart disease. SPACE sequence was performed in 20 patients (mean age, 17.6 ± 12.6 years, range 9 months–57 years, M: 13) with either unrepaired (N = 3) or post-repair (n = 17) congenital heart disease. All scans were performed on 1.5 T Aera scanners (Siemens). Two separate observers with expertise in cardiovascular imaging scored the quality of the images for blood suppression and definition of key anatomical structures in a blinded fashion using a 5 grade scoring system. Mean of average overall quality scores for two observers was 4 ± 0.62. All overall quality scores were greater than 3. None of the studies were deemed nondiagnostic. Mean length of the SPACE acquisition time was 12.7 min (4–21 min). There was no significant correlation between image quality and duration of scans. Lack of blood suppression was the limiting factor in image quality with the most common place being ascending aorta in nine patients. However, overall blood suppression score was very good with score of 3.9 ± 0.43. There was very good overall agreement between observers in rating the image quality (85.6 % agreement, kappa 0.5, standard error 0.04, p < 0.0001). The 3D-SPACE dark-blood sequence with near-isotropic spatial resolution coupled with respiratory and cardiac gating can be feasibly performed in all age groups with diagnostic image quality in all cases in this study.
引用
收藏
页码:1510 / 1514
页数:4
相关论文
共 50 条
  • [21] Utility of 3D printed cardiac models in congenital heart disease: a scoping review
    Illmann, Caroline F.
    Ghadiry-Tavi, Rouzbeh
    Hosking, Martin
    Harris, Kevin C.
    HEART, 2020, 106 (21) : 1631 - +
  • [22] Fast High-Resolution 3D Radar Imaging Based on 3D FISTA
    Ren, Jiaying
    Lu, Xinfei
    Guan, Jian
    Yin, Zhiping
    Ehen, Weidong
    2017 IEEE RADAR CONFERENCE (RADARCONF), 2017, : 815 - 818
  • [23] 3D Whole Heart Imaging for Congenital Heart Disease
    Greil, Gerald
    Tandon, Animesh
    Vieira, Miguel Silva
    Hussain, Tarique
    FRONTIERS IN PEDIATRICS, 2017, 5
  • [24] High-Resolution 3D Heart Models of Cardiomyocyte Subpopulations in Cleared Murine Heart
    Ren, Huiying
    Pu, Zhaoli
    Sun, Tianyi
    Chen, Tangting
    Liu, Leiying
    Liu, Zhu
    O'Shea, Christopher
    Pavlovic, Davor
    Tan, Xiaoqiu
    Lei, Ming
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [25] PTNet3D: A 3D High-Resolution Longitudinal Infant Brain MRI Synthesizer Based on Transformers
    Zhang, Xuzhe
    He, Xinzi
    Guo, Jia
    Ettehadi, Nabil
    Aw, Natalie
    Semanek, David
    Posner, Jonathan
    Laine, Andrew
    Wang, Yun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (10) : 2925 - 2940
  • [26] 3D detectors with high space and time resolution
    Loi, A.
    8TH YOUNG RESEARCHER MEETING, 2017, 2018, 956
  • [27] Experience with fully 3D PET and implications for future high-resolution 3D tomographs
    Bailey, DL
    Miller, MP
    Spinks, TJ
    Bloomfield, PM
    Livieratos, L
    Young, HE
    Jones, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 777 - 786
  • [29] High-Resolution 3D Radial bSSFP with IDEAL
    Moran, Catherine J.
    Brodsky, Ethan K.
    Bancroft, Leah Henze
    Reeder, Scott B.
    Yu, Huanzhou
    Kijowski, Richard
    Engel, Dorothee
    Block, Walter F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 95 - 104
  • [30] CSpace® High-Resolution Volumetric 3D Display
    Refai, Hakki H.
    Melnik, George
    Willner, Mark
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2013, 2013, 8738