Longitudinal stent deformation elongating to left main trunk

被引:3
|
作者
Matsushita K. [1 ]
Arakawa K. [1 ]
Hibi K. [2 ]
Kimura K. [2 ]
Umemura S. [3 ]
Himeno H. [1 ]
机构
[1] Division of Cardiology, Fujisawa City Hospital, Fujisawa, Kanagawa, 251-8511
[2] Division of Cardiology, Yokohama City University Medical Center, Yokohama, Kanagawa
[3] Department of Medical Science and Cardiorenal Medicine, Yokohama City University School of Medicine, Yokohama, Kanagawa
关键词
Percutaneous Coronary Intervention; Left Anterior Descend; Fractional Flow Reserve; Stent Strut; IVUS Image;
D O I
10.1007/s12928-013-0220-x
中图分类号
学科分类号
摘要
A 67-year-old woman was admitted with an acute coronary syndrome. Angiographic examination revealed diffuse severe stenosis of the left circumflex artery. A Pressure Wire Certus (St. Jude Medical, St. Paul, MN, USA) was passed to the second post-lateral (PL) branch. To prevent side-branch occlusion, a SION wire (Asahi Intecc Co., Aichi, Japan) was left in the first PL branch, and a SION blue wire (Asahi Intecc) was placed in the second obtuse marginal branch. We implanted an everolimus-eluting stent (PROMUS Element 2.5 × 24 mm, Boston Scientific, Natick, MA, USA) in the culprit lesion. After retrieving the protection wire in first PL branch with resistance, we performed post-dilatation. However, the intravascular ultrasound images showed that the proximal portion of the implanted stent had elongated approximately 2 mm to the left main trunk (LMT), although the position of the distal edge of the stent was unchanged. We decided to additionally place a stent from the ostium of the LMT to the proximal left anterior descending coronary artery, and a biolimus-eluting stent (NOBORI 3.0 × 18 mm, Terumo Co., Tokyo, Japan) was implanted successfully. Longitudinal stent elongation might be caused by the small number of links between the hoops of a stent, originally intended to improve deliverability. © 2013 Japanese Association of Cardiovascular Intervention and Therapeutics.
引用
收藏
页码:247 / 251
页数:4
相关论文
共 50 条
  • [21] Spontaneous kissing stent for total occlusion of the left main trunk complicated by Stanford Type A aortic dissection
    Matsumura, Hidenari
    Yashima, Fumiaki
    Shimoji, Kenichiro
    EUROPEAN HEART JOURNAL, 2024, 45 (13) : 1179 - 1179
  • [22] Stent Underexpansion as the Main Cause of In-Stent Restenosis of Left Main Disease
    Bernard, Alvin
    Ng, Sunanto
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0F) : F163 - F163
  • [23] Stent Retrieval from Left Main
    Kumsars, Indulis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (17) : S159 - S160
  • [24] SUPPORTED ANGIOPLASTY WITH SYNCHRONIZED RETROPERFUSION IN HIGH-RISK PATIENTS WITH LEFT MAIN TRUNK OR NEAR LEFT MAIN TRUNK OBSTRUCTION
    NANTO, S
    NISHIDA, K
    HIRAYAMA, A
    MISHIMA, M
    KOMAMURA, K
    MASAI, M
    SAKAKIBARA, T
    KODAMA, K
    AMERICAN HEART JOURNAL, 1993, 125 (02) : 301 - 309
  • [25] Very late stent thrombosis and longitudinal stent deformation
    Buysschaert, Ian
    Ughi, Giovanni J.
    Adriaenssens, Tom
    Vermeersch, Paul
    ACTA CARDIOLOGICA, 2017, 72 (02) : 216 - 217
  • [26] Complex intervention of the left main trunk with a 2-stent strategy and a DCB via a sheathless transradial approach
    Stoeckl, M.
    JOURNAL FUR KARDIOLOGIE, 2024, 31 (3-4):
  • [27] Proximal Optimization Technique with an Ultra-Short Balloon as a Bailout Strategy for Stent Protrusion into the Left Main Trunk
    Suzuki, Sho
    Murai, Kota
    Kataoka, Yu
    Noguchi, Teruo
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2023, 53 : S262 - S266
  • [28] 2 CASES WITH SPONTANEOUS SPASM OF LEFT MAIN TRUNK
    HATTORI, R
    NOSAKA, H
    NOBUYOSHI, M
    BRITISH HEART JOURNAL, 1982, 47 (03): : 249 - 252
  • [29] In-stent restenosis and longitudinal stent deformation: a case report
    Si, Daoyuan
    Tong, Yaliang
    Yu, Bo
    He, Yuquan
    Liu, Guohui
    BMC CARDIOVASCULAR DISORDERS, 2020, 20 (01)
  • [30] ECG study of complete left main trunk occlusion
    Fiol, Miquel
    Carrillo, Andres
    Bethencourt, Armando
    Rodriguez, Antonio
    Goldwasser, Diego
    de Luna, Antoni Bayes
    CIRCULATION, 2012, 125 (19) : E779 - E779