Measurements of blood viscosity using a pressure-scanning slit viscometer

被引:0
|
作者
Sehyun Shin
Sung-Woo Lee
Yun-Hee Ku
机构
[1] Kyungpook National University,School of Mechanical Engineering
来源
关键词
Blood; Viscosity; Pressure; Slit; Viscometer;
D O I
暂无
中图分类号
学科分类号
摘要
A newly designed pressure-scanning slit viscometer is developed to combine an optical device without refraction while measuring blood viscosity over a range of shear rates. The capillary tube in a previously designed capillary viscometer was replaced with a transparent slit, which is affordable to mount optical measurement of flowing blood cells. Using a pressure transducer, we measured the change of pressure in a collecting chamber with respect to the time, p(t), from which the viscosity and shear rate were mathematically calculated. For water, standard oil and whole blood, excellent agreement was found between the results from the pressure-scanning slit viscometer and those from a commercially available rotating viscometer. This new viscometer overcomes the drawbacks of the previously designed capillary viscometer in the measuring whole blood viscosity. First, the pressure-scanning slit viscometer can combine an optical instrument such as a microscope. Second, this design is low cost and simple (i.e., ease of operation, no moving parts, and disposable).
引用
收藏
页码:1036 / 1041
页数:5
相关论文
共 50 条
  • [31] THE FALLING NEEDLE VISCOMETER - A NEW TECHNIQUE FOR VISCOSITY MEASUREMENTS
    PARK, NA
    IRVINE, TF
    WARME UND STOFFUBERTRAGUNG-THERMO AND FLUID DYNAMICS, 1984, 18 (04): : 201 - 206
  • [32] THE FALLING NEEDLE VISCOMETER - A NEW TECHNIQUE FOR VISCOSITY MEASUREMENTS
    PARK, NA
    IRVINE, TF
    AMERICAN LABORATORY, 1988, 20 (11) : 57 - &
  • [33] A Capillary Tube Viscometer Designed for Measurements of Hydrogen Gas Viscosity at High Pressure and High Temperature
    Yusibani, Elin
    Nagahama, Yosuke
    Kohno, Masamichi
    Takata, Yasuyuki
    Woodfield, Peter L.
    Shinzato, Kanei
    Fujii, Motoo
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (06) : 1111 - 1124
  • [34] Viscosity measurements of dilute aqueous suspensions of cellulose nanocrystals using a rolling ball viscometer
    Gonzalez-Labrada, Erick
    Gray, Derek G.
    CELLULOSE, 2012, 19 (05) : 1557 - 1565
  • [35] Viscosity measurements of dilute aqueous suspensions of cellulose nanocrystals using a rolling ball viscometer
    Erick González-Labrada
    Derek G. Gray
    Cellulose, 2012, 19 : 1557 - 1565
  • [36] Viscosity measurement of polycarbonate by using a penetration viscometer
    Yang, FQ
    POLYMER ENGINEERING AND SCIENCE, 1997, 37 (01): : 101 - 104
  • [37] Measurement of the viscosity of biodiesel by using an optical viscometer
    Camas-Anzueto, J. L.
    Gomez-Perez, J.
    Meza-Gordillo, R.
    Anzueto-Sanchez, G.
    Perez-Patricio, M.
    Lopez-Estrada, F. R.
    Abud-Archila, M.
    Rios-Rojas, C.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 54 : 82 - 87
  • [38] Variable pressure-scanning electron microscopic observation of Walleye pollack surimi gel
    Kubota, S
    Tamura, Y
    Morioka, K
    Itoh, Y
    JOURNAL OF FOOD SCIENCE, 2003, 68 (01) : 307 - 311
  • [39] COMPARTMENTAL PRESSURE MEASUREMENTS - AN EXPERIMENTAL INVESTIGATION USING THE SLIT CATHETER
    RORABECK, CH
    CASTLE, GSP
    HARDIE, R
    LOGAN, J
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1981, 21 (06): : 446 - 449
  • [40] An automated system for performing continuous viscosity versus temperature measurements of fluids using an Ostwald viscometer
    Beaulieu, L. Y.
    Logan, E. R.
    Gering, K. L.
    Dahn, J. R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (09):