Chemical modifiers in arsenic determination in biological materials by tungsten coil electrothermal atomic absorption spectrometry

被引:0
|
作者
C. G. Bruhn
V. N. Huerta
J. Y. Neira
机构
[1] Universidad de Concepción,Departamento de Análisis Instrumental, Facultad de Farmacia
来源
关键词
Chemical modifiers; Arsenic; Tungsten coil electrothermal atomizer; Human hair; Clam;
D O I
暂无
中图分类号
学科分类号
摘要
Palladium, iridium, and rhodium are evaluated as possible chemical modifiers in the determination of As in digest solutions of biological materials (human hair and clam) by tungsten coil electrothermal atomic absorption spectrophotometry (TCA-AAS). The modifier in solution was applied onto the coil and thermally pre-reduced; the pre-reduction conditions, the amount of modifier, and the thermal program were optimized. Palladium was not satisfactory, whereas Ir and Rh were effective modifiers and rendered better relative sensitivity for As by a factor of 1.4 and 1.9, respectively compared to the case without modifier. Upon optimization of thermal conditions for As in pre-reduced Ir (2.0 µg) and Rh (2.0 µg) modifiers and in the digest solutions of the study matrices, Rh (2.0 µg) was more effective modifier and was selected as such. The mean within-day repeatability was 2.8% in consecutive measurements (25–100 µg L−1) (3 cycles, each of n=6) and confirmed good short-term stability of the absorbance measurements. The mean reproducibility was 4.4% (n=20 in a 3-day period) and the detection limit (3σblank/slope) was 29 pg (n=15). The useful coil lifetime in Rh modifier was extended to 300–400 firings. Validation was by determination of As in the certified reference material (CRM) of “Oyster tissue” solution with a percentage relative error (Erel%) of 2% and percentage relative standard deviation (RSD%) of 3% (n=4), and by analytical recovery of As spiked in CRM of human hair [94±8% (n=4)]. The methodology is simple, fast (sample readout frequency 21 h−1), reliable, of low cost, and was applied to the determination of As in hair samples of exposed and unexposed workers.
引用
收藏
页码:447 / 455
页数:8
相关论文
共 50 条
  • [31] Comparison of chemical modifiers for the determination of selenium by electrothermal atomic-absorption spectrometry
    Bulska, E
    Pyrzynska, K
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (9-10) : 1283 - 1291
  • [32] DETERMINATION OF ALUMINUM IN BIOLOGICAL-MATERIALS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY WITH A TUNGSTEN TUBE ATOMIZER
    OHTA, K
    YOKOYAMA, M
    ITOH, S
    KANECO, S
    MIZUNO, T
    ANALYTICA CHIMICA ACTA, 1994, 291 (1-2) : 115 - 120
  • [33] Tungsten-rhodium permanent chemical modifier for lead determination in digests of biological materials and sediments by electrothermal atomic absorption spectrometry
    Lima, ÉC
    Barbosa, F
    Krug, FJ
    Guaita, U
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) : 1601 - 1605
  • [34] Determination of cadmium in rice and water by tungsten coil electrothermal vaporization-atomic fluorescence spectrometry and tungsten coil electrothermal atomic absorption spectrometry after cloud point extraction
    Wen, Xiaodong
    Wu, Peng
    Chen, Li
    Hou, Xiandeng
    ANALYTICA CHIMICA ACTA, 2009, 650 (01) : 33 - 38
  • [35] Evaluation of different permanent modifiers for the determination of arsenic in environmental samples by electrothermal atomic absorption spectrometry
    Lima, ÉC
    Brasil, JL
    Vaghetti, JCP
    TALANTA, 2003, 60 (01) : 103 - 113
  • [36] Determination of chromium in urine by electrothermal atomic absorption spectrometry using different chemical modifiers
    Burguera, JL
    Burguera, M
    Rondon, C
    Rodríguez, L
    Carrero, P
    de Peña, YP
    Burguera, E
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) : 821 - 825
  • [37] CHEMICAL MODIFIERS IN THE DETERMINATION OF MOLYBDENUM IN HUMAN SERUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    BERMEJOBARRERA, P
    PITACALVO, C
    BERMEJOBARRERA, A
    BERMEJOMARTINEZ, F
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (04): : 265 - 268
  • [38] Platinum group metals as chemical modifiers for the determination of molybdenum by electrothermal atomic absorption spectrometry
    Piperaki, EA
    Thomaidis, NS
    Demis, I
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) : 1901 - 1906
  • [39] Comparison of chemical modifiers used for the determination of gold in ores by electrothermal atomic absorption spectrometry
    Gong, BL
    Liu, YM
    Li, JX
    Lin, TZ
    ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) : 247 - 251
  • [40] DETERMINATION OF SELENIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY .1. CHEMICAL MODIFIERS
    DOCEKALOVA, H
    DOCEKAL, B
    KOMAREK, J
    NOVOTNY, I
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (08) : 661 - 668