Selective determination of hydroquinone in the presence of catechol based on over-oxidized poly(hydroquinone)

被引:0
|
作者
Yongsheng Zhou
Xiaolin Ren
Chao Sheng
Xiaohui Chen
Yong Kong
Yongxin Tao
Zhidong Chen
机构
[1] Changzhou University,Institute of Petrochemical Technology
[2] Key Laboratory of Fine Petrochemicals of Jiangsu Province,undefined
关键词
Selective determination; Hydroquinone; Catechol; Poly(hydroquinone); Over-oxidation;
D O I
暂无
中图分类号
学科分类号
摘要
Selective determination of hydroquinone (HQ) in the presence of catechol (CC) was developed at an over-oxidized poly(hydroquinone) (PHQ) electrode. The electrochemical polymerization of HQ was carried out by potentiostatic method on a glassy carbon electrode. The resulting PHQ was over-oxidized in 0.10 mol/L NaOH solution and thus poly(p-benzoquinone) was obtained. Two dihydroxybenzene isomers, HQ and CC, show different voltammetric behavior at the over-oxidized PHQ electrode. The peak current of HQ is much larger than that of CC with the same concentration, which is attributed to the different position of the hydroxyl groups in benzene ring of the two isomers. The results from electrochemical impedance spectroscopy also demonstrates that the over-oxidized PHQ electrode has a stronger affinity for HQ over CC.
引用
收藏
页码:3159 / 3164
页数:5
相关论文
共 50 条
  • [21] Voltammetric determination of catechol and hydroquinone at poly (niacinamide) modified glassy carbon electrode
    Kumar, A. Anil
    Swamy, B. E. Kumara
    Ganesh, P. S.
    Rani, T. Shobha
    Reddy, G. Venkata
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 505 - 511
  • [22] Fabrication of Efficient and Selective Modified Graphene Paste Sensor for the Determination of Catechol and Hydroquinone
    Manjunatha, Jamballi G.
    SURFACES, 2020, 3 (03): : 473 - 483
  • [23] Poly-lysine/cyclodextrin polymer-MWCNTs as a Selective Sensing Platform for Hydroquinone and Catechol Simultaneous Determination
    Han, Qian
    He, Kangkang
    Han, Ruisheng
    Zhang, Jianda
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (07): : 6156 - 6169
  • [24] Poly (benzydamine) sensor for electrochemical resolution of catechol and hydroquinone
    Sukanya
    Kumara Swamy B.E.
    Shashikumara J.K.
    Materials Science for Energy Technologies, 2020, 3 : 640 - 647
  • [25] Indirect Kinetic–Spectrophotometric Determination of Resorcinol, Catechol, and Hydroquinone
    A. Afkhami
    H. A. Khatami
    Journal of Analytical Chemistry, 2001, 56 : 429 - 432
  • [26] DETERMINATION OF RESORCINOL IN SOLUTIONS CONTAINING PHENOL, HYDROQUINONE, AND CATECHOL
    CODELL, M
    TEITELL, L
    HOWARD, E
    ANALYTICAL CHEMISTRY, 1962, 34 (01) : 157 - &
  • [27] Poly(crystal violet) modified pencil graphite electrode sensor for the electroanalysis of catechol in the presence of hydroquinone
    Ganesh, P. S.
    Swamy, B. E. Kumara
    Fayemi, Omolola E.
    Sherif, El-Sayed M.
    Ebenso, Eno E.
    SENSING AND BIO-SENSING RESEARCH, 2018, 20 : 47 - 54
  • [28] Poly (Evans blue) sensor for catechol and hydroquinone: A voltammetric study
    Kuskur, Chethan M.
    Swamy, B. E. Kumara
    Jayadevappa, H.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 833 : 512 - 519
  • [29] Enhanced Electrochemical Determination of Catechol and Hydroquinone Based on Pd Nanoparticles/Poly(Taurine) Modified Glassy Carbon Electrode
    Kocak, Cagri Ceylan
    Kocak, Suleyman
    ELECTROANALYSIS, 2020, 32 (02) : 358 - 366
  • [30] Disposable graphite paper based sensor for sensitive simultaneous determination of hydroquinone and catechol
    Fan, Limei
    Li, Xueyan
    Kan, Xianwen
    ELECTROCHIMICA ACTA, 2016, 213 : 504 - 511