Internal femoral component rotation adversely influences load transfer in total knee arthroplasty: a cadaveric navigated study using the Verasense device

被引:0
|
作者
William A. Manning
Kanishka M. Ghosh
Alasdair Blain
Lee Longstaff
Steven P. Rushton
David J. Deehan
机构
[1] Freeman Hospital,Newcastle Surgical Training Centre Research Centre
[2] University of Newcastle Upon Tyne,School of Biology
[3] University Hospital of North Durham,Department of Orthopaedics
[4] Medical School,Institute of Cellular Medicine 4th Floor William Leech Building
关键词
Femoral rotation; Load; Flexion; Knee arthroplasty;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1577 / 1585
页数:8
相关论文
共 50 条
  • [1] Internal femoral component rotation adversely influences load transfer in total knee arthroplasty: a cadaveric navigated study using the Verasense device
    Manning, William A.
    Ghosh, Kanishka M.
    Blain, Alasdair
    Longstaff, Lee
    Rushton, Steven P.
    Deehan, David J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (05) : 1577 - 1585
  • [2] Femoral component rotation during total knee arthroplasty
    Olcott, CW
    Scott, RD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (367) : 39 - 42
  • [3] The effect of femoral component external rotation on tibial rotation in total knee arthroplasty
    Sherwood, CP
    Zhang, AX
    Petrella, AJ
    Miller, MC
    Berger, RA
    Rubash, HE
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 311 - 312
  • [4] Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension
    Walde, T. A.
    Bussert, J.
    Sehmisch, S.
    Balcarek, P.
    Sturmer, K. M.
    Walde, H. J.
    Frosch, K. H.
    KNEE, 2010, 17 (06): : 381 - 386
  • [5] Accuracy and repeatability of axes for femoral component rotation in total knee arthroplasty: a cadaver study
    Duffy, Siobhan A.
    Goudie, Stuart T.
    Deakin, Angela H.
    Payne, Anthony P.
    Deep, Kamal
    CURRENT ORTHOPAEDIC PRACTICE, 2016, 27 (04): : 427 - 432
  • [6] The effect of femoral component rotation on patellar tracking in total knee arthroplasty
    Luring, Christian
    Perlick, Lars
    Baethis, Holger
    Tingart, Markus
    Grifka, Joachim
    ORTHOPEDICS, 2007, 30 (11) : 965 - 967
  • [7] Femoral and tibial component rotation in total knee arthroplasty METHODS AND CONSEQUENCES
    Scott, R. D.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 140 - 143
  • [8] Computed tomographic evaluation of femoral component rotation in total knee arthroplasty
    Shrinand V. Vaidya
    Rajesh M. Gadhiya
    Vaibhav Bagaria
    Amar S. Ranawat
    Chitranjan S. Ranawat
    Indian Journal of Orthopaedics, 2013, 47 : 40 - 44
  • [9] Computed tomographic evaluation of femoral component rotation in total knee arthroplasty
    Vaidya, Shrinand V.
    Gadhiya, Rajesh M.
    Bagaria, Vaibhav
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (01) : 40 - 44
  • [10] Femoral component rotation in mobile-bearing total knee arthroplasty
    Boldt, J. G.
    Stiehl, J. B.
    Munzinger, U.
    Beverland, D.
    Keblish, P. A.
    KNEE, 2006, 13 (04): : 284 - 289