Femoral component rotation during total knee arthroplasty

被引:1
|
作者
Olcott, CW
Scott, RD
机构
[1] Univ Rochester, Med Ctr, Dept Orthopaed Surg, Rochester, NY 14642 USA
[2] Brigham & Womens Hosp, New England Baptist Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One-hundred consecutive posterior cruciate retaining total knee arthroplasties were performed by one surgeon in 81 patients with an average age of 69 years. Diagnoses included osteoarthritis in 93 knees and rheumatoid arthritis in seven. The femoral alignment necessary to create a rectangular flexion gap was determined and compared with Whiteside's line, the transepicondylar axis, and a line in 3 degrees external rotation relative to the posterior condyles of the femur. The transepicondylar axis most consistently recreated a balanced flexion space whereas 3 degrees external rotation off the posterior condyles was least consistent especially in knees in valgus.
引用
收藏
页码:39 / 42
页数:4
相关论文
共 50 条
  • [1] The effect of femoral component external rotation on tibial rotation in total knee arthroplasty
    Sherwood, CP
    Zhang, AX
    Petrella, AJ
    Miller, MC
    Berger, RA
    Rubash, HE
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 311 - 312
  • [2] The effect of femoral component rotation on patellar tracking in total knee arthroplasty
    Luring, Christian
    Perlick, Lars
    Baethis, Holger
    Tingart, Markus
    Grifka, Joachim
    ORTHOPEDICS, 2007, 30 (11) : 965 - 967
  • [3] Femoral and tibial component rotation in total knee arthroplasty METHODS AND CONSEQUENCES
    Scott, R. D.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 140 - 143
  • [4] Computed tomographic evaluation of femoral component rotation in total knee arthroplasty
    Shrinand V. Vaidya
    Rajesh M. Gadhiya
    Vaibhav Bagaria
    Amar S. Ranawat
    Chitranjan S. Ranawat
    Indian Journal of Orthopaedics, 2013, 47 : 40 - 44
  • [5] Computed tomographic evaluation of femoral component rotation in total knee arthroplasty
    Vaidya, Shrinand V.
    Gadhiya, Rajesh M.
    Bagaria, Vaibhav
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (01) : 40 - 44
  • [6] Femoral component rotation in mobile-bearing total knee arthroplasty
    Boldt, J. G.
    Stiehl, J. B.
    Munzinger, U.
    Beverland, D.
    Keblish, P. A.
    KNEE, 2006, 13 (04): : 284 - 289
  • [7] Femoral component rotation and Laurin angle after total knee arthroplasty
    Classen, Tim
    Wegner, Alexander
    Muller, Ralf-Dietrich
    Von Knoch, Marius
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (01): : 69 - 73
  • [8] A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty
    Olcott, CW
    Scott, RD
    JOURNAL OF ARTHROPLASTY, 2000, 15 (01): : 22 - 26
  • [9] The Ranawat Award Paper - Optimizing femoral component rotation in total knee arthroplasty
    Miller, MC
    Berger, RA
    Petrella, AJ
    Karmas, A
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 38 - 45
  • [10] Lateral retinacular release as a function of femoral component rotation in total knee arthroplasty
    Sodha, S
    Kim, J
    McGuire, KJ
    Lonner, JH
    Lotke, PA
    JOURNAL OF ARTHROPLASTY, 2004, 19 (04): : 459 - 463