Magnetically actuated glaucoma drainage device for regulating intraocular pressure after implantation

被引:0
|
作者
Inês C. F. Pereira
Ralph J. S. van Mechelen
Hans M. Wyss
Leonard Pinchuk
Henny J. M. Beckers
Jaap M. J. den Toonder
机构
[1] Eindhoven University of Technology,Microsystems, Department of Mechanical Engineering
[2] Eindhoven University of Technology,Institute for Complex Molecular Systems (ICMS)
[3] University Eye Clinic Maastricht,Ophthalmic Biophysics Center, Bascom Palmer Eye Institute
[4] Maastricht University Medical Centre+ (MUMC+),undefined
[5] InnFocus,undefined
[6] Inc.,undefined
[7] a Santen Company,undefined
[8] University of Miami Miller School of Medicine,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The key risk factor for glaucoma is increased intraocular pressure (IOP). Glaucoma drainage devices implanted in the eye can reduce IOP and thus stop disease progression. However, most devices currently used in clinical practice are passive and do not allow for postsurgical IOP control, which may result in serious complications such as hypotony (i.e., excessively low IOP). To enable noninvasive IOP control, we demonstrate a novel, miniature glaucoma implant that will enable the repeated adjustment of the hydrodynamic resistance after implantation. This is achieved by integrating a magnetic microvalve containing a micropencil-shaped plug that is moved using an external magnet, thereby opening or closing fluidic channels. The microplug is made from biocompatible poly(styrene-block-isobutylene-block-styrene) (SIBS) containing iron microparticles. The complete implant consists of an SIBS drainage tube and a housing element containing the microvalve and fabricated with hot embossing using femtosecond laser-machined glass molds. Using in vitro and ex vivo microfluidic experiments, we demonstrate that when the microvalve is closed, it can provide sufficient hydrodynamic resistance to overcome hypotony. Valve function is repeatable and stable over time. Due to its small size, our implant is a promising, safe, easy-to-implant, minimally invasive glaucoma surgery device.
引用
收藏
相关论文
共 50 条
  • [41] Human amniotic membrane transplantation for tube exposure after glaucoma drainage device implantation
    Papadaki, Thekla G.
    Siganos, Charalambos S.
    Zacharopoulos, Ioannis P.
    Panteleontidis, Vasssilios
    Charissis, Spyridon K.
    [J]. JOURNAL OF GLAUCOMA, 2007, 16 (01) : 171 - 172
  • [42] Outcomes of Trabeculectomy and Glaucoma Drainage Devices for Elevated Intraocular Pressure After Penetrating Keratoplasty
    Yakin, Mehmet
    Eksioglu, Umit
    Yalniz-Akkaya, Zuleyha
    Uzman, Selma
    Singar-Ozdemir, Evin
    Gultekin, Kemal
    Demirok, Gulizar
    Yalvac, Ilgaz
    Ornek, Firdevs
    Burcu, Ayse
    [J]. CORNEA, 2018, 37 (06) : 705 - 711
  • [43] Long-term Visual Field Outcomes after Glaucoma Drainage Device Implantation
    Yarur, Daniela
    De Gainza, Agustina
    Morales, Esteban
    Caprioli, Joseph
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [44] Pirfenidone inhibits fibrosis in foreign body reaction after glaucoma drainage device implantation
    Jung, Kyoung In
    Park, Chan Kee
    [J]. DRUG DESIGN DEVELOPMENT AND THERAPY, 2016, 10 : 1477 - 1488
  • [45] Ocular motility disturbances after glaucoma drainage device implantation for paediatric glaucoma: a cross-sectional study
    Leahy, Kate Elspeth
    MacNeill, Katelyn
    Locke, Jeff
    Sobey, Stephanie
    Kraft, Stephen P.
    Ali, Asim
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (01) : 54 - 59
  • [46] Surgical Outcomes of Glaucoma Drainage Device Implantation in Refractory Glaucoma Patients in Thailand
    Rojananuangnit, Kulawan
    Jiaranaisilawong, Prangkhwan
    Rattanaphaithun, Onvipa
    Sathim, Wanwisa
    [J]. CLINICAL OPHTHALMOLOGY, 2022, 16 : 4163 - 4178
  • [47] Retinal detachment in patients with a preexisting glaucoma drainage device - Anatomic, visual acuity, and intraocular pressure outcomes
    Benz, MS
    Scott, IU
    Flynn, HW
    Gedde, SJ
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (03): : 283 - 287
  • [48] Intraocular pressure reduction after cataract surgery with implantation of a trabecular microbypass device
    Brown, Reay H.
    Gibson, Zachary
    Zhong, Le
    Lynch, Mary G.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (06): : 1318 - 1319
  • [49] Impact of Lens Status on Glaucoma Drainage Device Implantation Outcomes
    Hekmatjah, Natan
    Stallworth, Jeannette
    Yu, Yinxi
    Oatts, Julius
    Ying, Gui-Shuang
    Han, Ying
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [50] Acute Increase in Intraocular Pressure in a Patient With a Glaucoma Drainage Implant
    Falcone, Michelle M.
    Chang, Ta C.
    Cavuoto, Kara M.
    [J]. JAMA OPHTHALMOLOGY, 2016, 134 (04) : 457 - 458