The innovative method of high accuracy interferometric calibration of the Precision Laser Inclinometer

被引:7
|
作者
Azaryan N. [1 ]
Budagov J. [1 ]
Gayde J.-C. [2 ]
Di Girolamo B. [2 ]
Glagolev V. [1 ]
Lyablin M. [1 ]
Mergelkuhl D. [2 ]
Shirkov G. [1 ]
机构
[1] Joint Institute for Nuclear Research, Dubna, Moscow oblast
[2] European Organization for Nuclear Research (CERN), Geneva
关键词
D O I
10.1134/S154747711701006X
中图分类号
学科分类号
摘要
In this report a high accuracy method for an interferometric calibration of the Precision Laser Inclinometer (PLI) is proposed. The method is based on the simultaneous measurement of: (a) the PLI base calibration slope (angle), set by a piezoelectric positioner, via laser interferometry and (b) the PLI response signal. A calibration coefficient of 322.5 ± 1.9 μrad/V has been determined experimentally in an interval [4 × 10–7, 4 × 10–6] rad in which there is a linear dependence between the PLI-signal and the calibration angle. © 2017, Pleiades Publishing, Ltd.
引用
收藏
页码:112 / 122
页数:10
相关论文
共 50 条
  • [31] The compensation of the noise due to angular oscillations of the laser beam in the Precision Laser Inclinometer
    Azaryan N.
    Budagov J.
    Lyablin M.
    Pluzhnikov A.
    Di Girolamo B.
    Gayde J.-C.
    Mergelkuhl D.
    Physics of Particles and Nuclei Letters, 2017, 14 (6) : 930 - 938
  • [32] Professional Precision Laser Inclinometer: the Noises Origin and Signal Processing
    Azaryan, N.
    Budagov, J.
    Glagolev, V.
    Lyablin, M.
    Pluzhnikov, A.
    Seletsky, A.
    Trubnikova, G.
    Di Girolamo, B.
    Gayde, J. -C.
    Mergelkuhlb, D.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2019, 16 (03) : 264 - 276
  • [33] Professional Precision Laser Inclinometer: the Noises Origin and Signal Processing
    N. Azaryan
    J. Budagov
    V. Glagolev
    M. Lyablin
    A. Pluzhnikov
    A. Seletsky
    G. Trubnikova
    B. Di Girolamo
    J.-C. Gayde
    D. Mergelkuhlb
    Physics of Particles and Nuclei Letters, 2019, 16 : 264 - 276
  • [34] Development of laser interferometric high-precision geometry monitor for JASMINE
    Niwa, Yoshito
    Arai, Koji
    Ueda, Akitoshi
    Sakagami, Masaaki
    Gouda, Naoteru
    Kobayashi, Yukiyasu
    Yamada, Yoshiyuki
    Yano, Taihei
    SPACE TELESCOPES AND INSTRUMENTATION 2008: OPTICAL, INFRARED, AND MILLIMETER, PTS 1 AND 2, 2008, 7010
  • [35] The sensitivity limitation by the recording ADC to Laser Fiducial Line and Precision Laser Inclinometer
    Batusov V.
    Budagov J.
    Lyablin M.
    Shirkov G.
    Gayde J.-C.
    Mergelkuhl D.
    Physics of Particles and Nuclei Letters, 2015, 12 (7) : 813 - 818
  • [36] High precision calibration of interferometric data through the removal of fixed-pattern residuals
    Tycner, Christopher
    Benson, J. A.
    Hutter, D. J.
    Schmitt, H. R.
    Zavala, R. T.
    ADVANCES IN STELLAR INTERFEROMETRY PTS 1 AND 2, 2006, 6268
  • [37] A high-precision self-calibration method for laser tracker without common points
    Qi Z.
    Zhu D.
    Luo T.
    Miao X.
    He X.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2024, 53 (02):
  • [38] INTERFEROMETRIC CALIBRATION OF PRECISION SCREWS AND CONTROL OF RULING ENGINES
    HARRISON, GR
    ARCHER, JE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1951, 41 (08) : 495 - 503
  • [39] Comparative Study of the Accuracy of High-Precision Angle Calibration Systems
    Kasparaitis, A.
    Barakauskas, A.
    Lazdinas, R.
    Simkevicius, A.
    MECHANIKA 2013: PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE, 2013, : 118 - 122
  • [40] EVALUATION OF PRECISION AND ACCURACY IN CALIBRATION OF HYDROPHONES
    BLUE, JE
    REPORT OF NRL PROGRESS, 1973, (MAR): : 33 - 33