Interactive MR-guided biopsies of maxillary and skull-base lesions in an open-MR system: first clinical results

被引:0
|
作者
G. M. Kacl
F. R. Carls
C. Moll
J. F. Debatin
机构
[1] Department of Medical Radiology,
[2] University Hospital Zurich,undefined
[3] Rämistrasse 100,undefined
[4] CH-8091 Zurich,undefined
[5] Switzerland,undefined
[6] Department of Maxillofacial Surgery,undefined
[7] University Hospital Zurich,undefined
[8] Rämistrasse 100,undefined
[9] CH-8091 Zurich,undefined
[10] Switzerland,undefined
[11] Department of Pathology,undefined
[12] University Hospital Zurich,undefined
[13] Rämistrasse 100,undefined
[14] CH-8091 Zurich,undefined
[15] Switzerland,undefined
来源
European Radiology | 1999年 / 9卷
关键词
Key words: MR-guided biopsy; Ameloblastoma; Non-Hodgkin's lymphoma; Dental cysts; Head and neck biopsy;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to explore the potential of interactive MR-guided biopsies in the maxillary and skull base region using a 0.5-T open-configuration scanner in patients with tumours affecting the maxilla or skull base. Ten patients with cystic or solid tumours affecting the maxillary and skull base regions underwent MR-guided biopsy in a superconducting, open 0.5-T MR system equipped with an optical frameless stereotaxic system. T2-weighted spin-echo images were acquired prior to and following biopsy, which was performed with 18- or 22-G needles using an enoral or percutaneous approach following infiltration of the skin, mucosa and periosteum with local anaesthetics. The position of the needle tip was continuously updated on fast T1-weighted gradient-recalled-echo images (TR 19 ms, TE 7.1 ms, flip angle 30 °, slice thickness 1 cm, field of view 24 × 24 cm) using the frameless stereotaxic system. In addition, the needle was identified based on the associated susceptibility artefact in all three planes. Once the target lesion had been reached, cytology material was aspirated. All ten patients tolerated the interactive MR-guided biopsies well without complications. Vital structures, including the brain, neurovascular bundles, vessels and eyes, were visualized on MR imaging and could be spared. There was no difference in the use of 18- or 22-G non-ferromagnetic needles concerning the susceptibility artefact. Sufficient material for cytological analysis was obtained in nine of ten cases. The mean biopsy time was 15 min. Interactive MR-guided biopsies of the head and neck in an open system are technically feasible and safe. Monitoring of the needle path in multiple planes permits the interactive adjustment of the needle course in near real time. Interactive MR-guided biopsies may well replace open surgical procedures in the maxillary region in selected patients.
引用
收藏
页码:487 / 492
页数:5
相关论文
共 50 条
  • [1] Interactive MR-guided biopsies of maxillary and skull-base lesions in an open-MR system: first clinical results
    Kacl, GM
    Carls, FR
    Moll, C
    Debatin, JF
    EUROPEAN RADIOLOGY, 1999, 9 (03) : 487 - 492
  • [2] Interactive MR-guided biopsies of the maxilla and the skull base
    Kacl, GM
    Carls, FP
    Sailer, HF
    Romanowski, B
    Debatin, JF
    Schulthess, GK
    RADIOLOGY, 1997, 205 : 1644 - 1644
  • [3] Interactive percutaneous MR-guided biopsies of thyroid lesions
    Kacl, GM
    Bicik, J
    Schoenenberger, AW
    Steiner, P
    Debatin, JF
    VonSchulthess, GK
    RADIOLOGY, 1996, 201 : 450 - 450
  • [4] MR-guided biopsies of lesions in the retroperitoneal space: technique and results
    Zangos, S
    Eichler, K
    Wetter, A
    Lehnert, T
    Hammerstingl, R
    Diebold, T
    Reichel, P
    Herzog, C
    Hansmann, ML
    Mack, MG
    Vogl, TJ
    EUROPEAN RADIOLOGY, 2006, 16 (02) : 307 - 312
  • [5] MR-guided biopsies of undetermined liver lesions: Technique and results
    Zangos, S
    Kiefl, D
    Eichler, K
    Engelmann, K
    Heller, M
    Herzog, C
    Mack, MG
    Jacobi, V
    Vogl, TJ
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (05): : 688 - 694
  • [6] MR-guided biopsies of lesions in the retroperitoneal space: technique and results
    S. Zangos
    K. Eichler
    A. Wetter
    T. Lehnert
    R. Hammerstingl
    T. Diebold
    P. Reichel
    C. Herzog
    M.-L. Hansmann
    M. G. Mack
    T. J. Vogl
    European Radiology, 2006, 16 : 307 - 312
  • [7] MR-guided biopsies in an open-configuration MR imaging system: A case report
    Schoenenberger, AW
    Steiner, P
    Debatin, JF
    Pfammatter, T
    Kacl, GM
    RADIOLOGE, 1996, 36 (09): : 705 - 708
  • [8] Interactive MR-guided biopsies before maxillofacial surgery
    Carls, FR
    Kacl, GM
    Debatin, JF
    Longerich, U
    Warnke, T
    Sailer, HF
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 744 - 750
  • [9] INTERACTIVE MR-GUIDED BIOPSY IN AN OPEN-CONFIGURATION MR-IMAGING SYSTEM
    SILVERMAN, SG
    COLLICK, BD
    FIGUEIRA, MR
    KHORASANI, R
    ADAMS, DF
    NEWMAN, RW
    TOPULOS, GP
    JOLESZ, FA
    RADIOLOGY, 1995, 197 (01) : 175 - 181
  • [10] Target definition and trajectory optimization for interactive MR-guided biopsies of brain tumors in an open configuration MRI system
    Kollias, SS
    Bernays, R
    Marugg, RA
    Romanowski, B
    Yonekawa, Y
    Valavanis, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 143 - 159