Target definition and trajectory optimization for interactive MR-guided biopsies of brain tumors in an open configuration MRI system

被引:31
|
作者
Kollias, SS
Bernays, R
Marugg, RA
Romanowski, B
Yonekawa, Y
Valavanis, A
机构
[1] Univ Zurich Hosp, Inst Neuroradiol & Magnet Resonance Ctr, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Neurosurg, CH-8091 Zurich, Switzerland
来源
关键词
brain biopsy; cerebral tumors; functional MRI; perfusion; interventional MRI; neurosurgical planning;
D O I
10.1002/jmri.1880080127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present an imaging strategy for planning and guiding brain biopsies in an open configuration MR system. Preprocedure imaging was performed in a 1.5-T MR system and was designed to provide, in a clinically efficient manner. high resolution anatomical and functional/physiologic information for precise definition and tissue characterization of the target, aiming at optimization of the biopsy trajectory for planning a safe and accurate procedure. The interventions were performed in a .5-T open bore magnet, and imaging was optimized to provide the imaging quality and temporal resolution necessary for performing the procedure interactively in near real time. Brain biopsies of 21 patients were performed in a 10-month period. Segmentation and surface rendering analysis of the lesions and vascular structures and dynamic MR perfusion and cortical activation studies provided an efficient and comprehensive way to appreciate the relationship of the target to surrounding vital structures, improved tissue characterization and definition of the tumor margins, and demonstrated the location of essential cortex, allowing appropriate placement of the burr hole and choice of optimal trajectory. Interactive protocols provided good visualization of the target and the interventional devices and offered the operator real-time feedback and control of the procedure. No complications were encountered. Advanced methods of image acquisition and processing for accurate planning of interventional brain procedures and interactive imaging with MR guidance render feasible the performance of safe and accurate neurointerventional procedures.
引用
收藏
页码:143 / 159
页数:17
相关论文
共 33 条
  • [1] MR-guided biopsies in an open-configuration MR imaging system: A case report
    Schoenenberger, AW
    Steiner, P
    Debatin, JF
    Pfammatter, T
    Kacl, GM
    RADIOLOGE, 1996, 36 (09): : 705 - 708
  • [2] INTERACTIVE MR-GUIDED BIOPSY IN AN OPEN-CONFIGURATION MR-IMAGING SYSTEM
    SILVERMAN, SG
    COLLICK, BD
    FIGUEIRA, MR
    KHORASANI, R
    ADAMS, DF
    NEWMAN, RW
    TOPULOS, GP
    JOLESZ, FA
    RADIOLOGY, 1995, 197 (01) : 175 - 181
  • [3] Interactive MR-guided biopsies of maxillary and skull-base lesions in an open-MR system: first clinical results
    G. M. Kacl
    F. R. Carls
    C. Moll
    J. F. Debatin
    European Radiology, 1999, 9 : 487 - 492
  • [4] Interactive MR-guided biopsies of maxillary and skull-base lesions in an open-MR system: first clinical results
    Kacl, GM
    Carls, FR
    Moll, C
    Debatin, JF
    EUROPEAN RADIOLOGY, 1999, 9 (03) : 487 - 492
  • [5] MR-guided discography using an open 1 Tesla MRI system
    Streitparth, Florian
    Hartwig, T.
    Schnackenburg, B.
    Strube, P.
    Putzier, M.
    Chopra, S.
    De Bucourt, M.
    Hamm, B.
    Teichgraeber, U.
    EUROPEAN RADIOLOGY, 2011, 21 (05) : 1043 - 1049
  • [6] MR-guided discography using an open 1 Tesla MRI system
    Florian Streitparth
    T. Hartwig
    B. Schnackenburg
    P. Strube
    M. Putzier
    S. Chopra
    M. De Bucourt
    B. Hamm
    U. Teichgräber
    European Radiology, 2011, 21 : 1043 - 1049
  • [7] MR-guided biopsies of soft-tissue tumors with a conventional high-field MR system
    Vogl, TJ
    Mack, MG
    Balzer, JO
    Hammerstingl, R
    Pegios, W
    Lobeck, H
    RADIOLOGY, 1996, 201 : 468 - 468
  • [8] MR-guided biopsies of soft tissue tumors on a conventional high-field MR-system
    Mack, MG
    Vogl, TJ
    Balzer, JO
    Pegios, W
    Hammerstingl, R
    Felix, R
    RADIOLOGY, 1997, 205 : 156 - 156
  • [9] MR-Guided procedures using contemporaneous imaging frameless stereotaxis in an open-configuration system
    Lee, MH
    Lufkin, RB
    Borges, A
    Lu, DSK
    Sinha, S
    Farahani, K
    Villabalanca, P
    Curran, J
    Hall, T
    Atkinson, D
    Kangarloo, H
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (06) : 998 - 1005
  • [10] Open-configuration MR-guided microwave thermocoagulation therapy for metastatic liver tumors from breast cancer
    Hajime Abe
    Yoshimasa Kurumi
    Shigeyuki Naka
    Hisanori Shiomi
    Tomoko Umeda
    Hiroyuki Naitoh
    Yoshihiro Endo
    Kazuyoshi Hanasawa
    Shigehiro Morikawa
    Tohru Tani
    Breast Cancer, 2005, 12 (1) : 26 - 31