In situ mechanical observations during nanoindentation inside a high-resolution scanning electron microscope

被引:0
|
作者
K.A. Rzepiejewska-Malyska
G. Buerki
J. Michler
R.C. Major
E. Cyrankowski
S.A.S. Asif
O.L. Warren
机构
[1] Swiss Federal Laboratories for Material Testing and Research—EMPA,
[2] Hysitron,undefined
[3] Inc.,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In nanoindentation, the occurrence of cracks, pileup, sink-in, or film delamination adds additional complexity to the analysis of the load–displacement curves. Many techniques and analysis methods have been used to extract both qualitative and quantitative information from the indentation test both during and after the test. Much of this information is obtained indirectly or may even be overlooked by current testing methods (e.g., cracks that open only during the loading cycle of the test may go unnoticed from a typical residual indentation analysis). Here we report on the development of a miniature depth-sensing nanoindentation instrument and its integration into a high-resolution scanning electron microscope. Real-time observation of the nanoindentation test via scanning electron microscopy allows for visualization and detection of certain events such as crack initiation, pileup, or sink-in, and other material deformation phenomena. Initial results from aluminum 〈100〉 and a thin gold film (∼225 nm) are presented.
引用
收藏
页码:1973 / 1979
页数:6
相关论文
共 50 条
  • [21] HIGH-RESOLUTION THERMIONIC CATHODE SCANNING TRANSMISSION ELECTRON-MICROSCOPE
    BROERS, AN
    APPLIED PHYSICS LETTERS, 1973, 22 (11) : 610 - 612
  • [22] Fracture of polycrystalline graphene membranes by in situ nanoindentation in a scanning electron microscope
    Suk, Ji Won
    Mancevski, Vladimir
    Hao, Yufeng
    Liechti, Kenneth M.
    Ruoff, Rodney S.
    PHYSICA STATUS SOLIDI-RAPID RESEARCH LETTERS, 2015, 9 (10): : 564 - 569
  • [23] Observations of surface-related phenomena during in situ nanoindentation in a transmission electron microscope (TEM)
    Minor, AM
    Lilleodden, ET
    Stach, EA
    Morris, JW
    SURFACE ENGINEERING: SCIENCE AND TECHNOLOGY II, 2002, : 305 - 313
  • [24] OBSERVATIONS OF THE AU/SI(111) SYSTEM WITH A HIGH-RESOLUTION ULTRAHIGH-VACUUM SCANNING ELECTRON-MICROSCOPE
    ENDO, A
    INO, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (10): : 4718 - 4725
  • [25] HIGH-RESOLUTION ELECTRON-MICROSCOPE
    不详
    ELECTRICAL REVIEW, 1976, 199 (01): : 52 - 52
  • [26] HIGH-RESOLUTION ELECTRON-MICROSCOPE
    HONDA, T
    WATANABE, E
    HARADA, Y
    JOURNAL OF ELECTRON MICROSCOPY, 1983, 32 (01): : 66 - 67
  • [27] HIGH-RESOLUTION ELECTRON-MICROSCOPE
    不详
    MEASUREMENT AND CONTROL, 1979, 12 (08): : 324 - 324
  • [28] EFFECT OF MECHANICAL STABILITY ON PERFORMANCE OF A HIGH-RESOLUTION ELECTRON-MICROSCOPE
    CHIU, W
    GLAESER, RM
    JOURNAL OF ELECTRON MICROSCOPY, 1977, 26 (02): : 181 - 182
  • [29] APPLICATION OF A HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPE TO BIOLOGICAL-RESEARCH
    TANAKA, K
    JOURNAL OF ELECTRON MICROSCOPY, 1988, 37 (02): : 100 - 101
  • [30] FRACTURE OF HUMAN DENTIN - HIGH-RESOLUTION SCANNING ELECTRON-MICROSCOPE STUDY
    SPECTOR, M
    TAYLOR, SE
    JOURNAL OF DENTAL RESEARCH, 1976, 55 (06) : 1136 - 1136