Development and evaluation of loop-mediated isothermal amplification assay for rapid and sensitive detection of potato cyst nematode, Globodera pallida from soil

被引:0
|
作者
Aarti Bairwa
Bhawna Dipta
Gaurav Verma
E. P. Venkatasalam
A. Shanthi
A. Jeevalatha
Kailash C. Naga
Sanjeev Sharma
Deepali Thakur
Priyank Hanuman Mhatre
机构
[1] ICAR-Central Potato Research Institute,Department of Nematology
[2] ICAR-Central Potato Research Institute,undefined
[3] Regional Station,undefined
[4] Tamil Nadu Agricultural University,undefined
[5] ICAR-Indian Institute of Spices Research,undefined
来源
3 Biotech | 2023年 / 13卷
关键词
Detection; LAMP; Management; Mitochondrial-SCAR; Potato;
D O I
暂无
中图分类号
学科分类号
摘要
Potato cyst nematodes, Globodera pallida and G. rostochiensis, are economically important and difficult to manage pests of the potato crop. The cyst of both the species looks similar and it is difficult to differentiate once it turns brown upon maturity. Early detection of the PCN at the species level is crucial to avoid its further spread and for adopting the appropriate management strategies. Therefore, in the present study, highly specific and sensitive loop-mediated isothermal amplification (LAMP) assay was developed to amplify mitochondrial-Sequence Characterized Amplified Region (SCAR) sequence of potato cyst nematode, G. pallida. The LAMP assay was completed within a shorter incubation period of 60 min at 60 °C followed by the reaction termination at 80 °C for 5 min. The developed LAMP assay exhibited high specificity for G. pallida and did not detect any other species including its sibling species, G. rostochiensis. In sensitivity tests, the assay detected G. pallida at 1000 times less DNA concentration (10 fg/µl) as compared to conventional PCR (10 pg/µl). In addition to this, the developed LAMP assay was tested for the detection of G. pallida directly from the soil samples, and even a single cyst mixed with soil was successfully detected by the developed assay. Moreover, the utility of low-cost instruments like hot water bath was also demonstrated for the detection of G. pallida from the soil. The developed LAMP is a rapid, highly specific, sensitive, and cost-effective technique for the species-specific detection of G. pallida. The developed assay will facilitate the rapid detection of G. pallida at quarantine stations as well as from the fields which will help to stop its further spread in new areas and also to devise effective management strategies for sustainable potato production.
引用
收藏
相关论文
共 50 条
  • [41] Development and evaluation of a loop-mediated isothermal amplification assay for rapid detection of Leishmania amazonensis in skin samples
    de Lima Celeste, Jordanna Luiza
    Caldeira, Roberta Lima
    Pires, Simone da Fonseca
    Silveira, Karine Dias
    Soares, Rodrigo Pedro
    de Andrade, Helda Monteiro
    EXPERIMENTAL PARASITOLOGY, 2019, 203 : 23 - 29
  • [42] Development and evaluation of loop-mediated isothermal amplification for rapid detection of Haemophilus parasuis
    Wang Yang
    Fang Ying
    Liu Yingyu
    Chen Pin
    Li Wentao
    Liu Shuqing
    Zou Haoyong
    He Qigai
    FEMS MICROBIOLOGY LETTERS, 2010, 313 (01) : 54 - 60
  • [43] Development and evaluation of loop-mediated isothermal amplification protocols for rapid and sensitive detection of plant pathogenic bacteria
    Li, X.
    Nie, J. B.
    Ward, L.
    De Boer, S. H.
    CANADIAN JOURNAL OF PLANT PATHOLOGY-REVUE CANADIENNE DE PHYTOPATHOLOGIE, 2010, 32 (03): : 417 - 417
  • [44] Development and evaluation of loop-mediated isothermal amplification assay for rapid and sensitive detection of canine parvovirus DNA directly in faecal specimens
    Mukhopadhyay, H. K.
    Amsaveni, S.
    Matta, S. L.
    Antony, P. X.
    Thanislass, J.
    Pillai, R. M.
    LETTERS IN APPLIED MICROBIOLOGY, 2012, 55 (03) : 202 - 209
  • [45] Development of a real-time loop-mediated isothermal amplification assay for the sensitive and rapid detection of Listeria monocytogenes
    Ye, L.
    Li, Y.
    Zhao, J.
    Zhang, Z.
    Meng, H.
    Yan, H.
    Miyoshi, S. -i.
    Shi, L.
    LETTERS IN APPLIED MICROBIOLOGY, 2015, 61 (01) : 85 - 90
  • [46] Rapid detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification assay
    Yuan, Xin
    Bai, Changqing
    Cui, Qian
    Zhang, Han
    Yuan, Jing
    Niu, Kaiwen
    Feng, Yuzhong
    Jin, Xin
    Li, Puyuan
    Liu, Huiying
    MEDICINE, 2018, 97 (25)
  • [47] Development of Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid Detection of Cannabis sativa
    Kitamura, Masashi
    Aragane, Masako
    Nakamura, Kou
    Watanabe, Kazuhito
    Sasaki, Yohei
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2016, 39 (07) : 1144 - 1149
  • [48] Development of a loop-mediated isothermal amplification assay for rapid and specific detection of Xanthomonas perforans
    Dong, A.
    Hudson, O.
    Stackhouse, T. L.
    Waliullah, S.
    Ji, P.
    Ali, E.
    PHYTOPATHOLOGY, 2021, 111 (10) : 34 - 35
  • [49] Development of a loop-mediated isothermal amplification (LAMP) assay for the rapid detection of Beiji nairovirus
    Wang, Yiwen
    Huang, Jing
    Chen, Meiyi
    Jin, Zha
    Liu, Tingting
    Jiang, Xi
    Huang, Rongsheng
    Hu, Kairao
    Wei, Zhengkai
    Liu, Quan
    MICROBIAL PATHOGENESIS, 2025, 199
  • [50] Development of reverse transcription loop-mediated isothermal amplification assay for sensitive and rapid detection of Hosta virus X
    Zhang, Yongjiang
    Li, Xiaojuan
    Li, Man
    Qiu, Yanhong
    Li, Guifen
    Li, Yongqiang
    Zhu, Shuifang
    JOURNAL OF PHYTOPATHOLOGY, 2018, 166 (04) : 291 - 297